Dominique Fabre

Dominique Fabre

Auto-generated profile, based on publicly available information

Dominique Fabre

Paris-Saclay University, Marie Lannelongue Hospital, Le Plessis-Robinson, France

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in European Journal of Vascular and Endovascular Surgery
Verified
Journal Article
Closed access
DFDominique Fabre
Dominique Fabre
JMJustine Mougin
Justine Mougin
DMDelphine Mitilian
Delphine Mitilian
FCFrederic Cochennec
Frederic Cochennec
CACarlos Garcia Alonso
Carlos Garcia Alonso
SHStephan Haulon
Stephan Haulon

30 January 2023 in European Journal of Vascular and Endovascular Surgery
Verified
Journal Article
Closed access
THThomas Le Houérou
Thomas Le Houérou
FÁFrancisco Álvarez-Marcos
Francisco Álvarez-Marcos
AGAntoine Gaudin
Antoine Gaudin
CBCôme Bosse
Côme Bosse
ACAlessandro Costanzo
Alessandro Costanzo
DFDominique Fabre
Dominique Fabre

1 April 2021 in Journal of Vascular Surgery
Verified
Journal Article
Closed access
SMSébastien Multon
Sébastien Multon
CDChristian Denier
Christian Denier
PCPhillippe Charbonneau
Phillippe Charbonneau
MSMariana Sarov
Mariana Sarov
DBDavid Boulate
David Boulate
DFDominique Fabre
Dominique Fabre

25 March 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
THThomas Le Houérou
Thomas Le Houérou
PNPetroula Nana
Petroula Nana
MPMathieu PERNOT
Mathieu PERNOT
JGJulien Guihaire
Julien Guihaire
AGAntoine Gaudin
Antoine Gaudin
SHStephan Haulon
Stephan Haulon
Background: In situ laser-fenestrated thoracic aortic endovascular repair (FTEVAR) has emerged as a valuable alternative for aortic arch management. This review assessed the early and follow-up outcomes of in situ laser-FTEVAR in aortic arch pathologies. Methods: The PRISMA statement was followed. The English literature was searched, via Ovid, until 15 October 2022. Observational studies, published after 2000, reporting on early and follow-up outcomes for the in situ laser-FTEVAR were eligible. The Newcastle–Ottawa Scale was used to assess the risk of bias. Primary outcomes were the technical success, stroke, and mortality at 30-days, and the secondary were the mortality and reintervention during follow-up. Results: Six retrospective studies from 591 and 247 patients were included. Fifty-nine (23.9%) patients were managed for aortic arch aneurysms and 146 (59.1%) for dissections; 22.6% of them for type A. Technical success was at 98% (range 90–100%). Eight patients died (3.2%) and 11 cases presented any type of stroke (4.5%) during the 30-day follow-up. The mean follow-up was 15 months (1–40 months). Ten deaths were reported (4.2%); one was aortic-related (10%). Thirteen re-interventions (6.0%) were performed. Conclusions: In situ laser-FTEVAR for aortic arch repair may be performed with high technical success and low 30-day and midterm follow-up mortality, stroke, and re-intervention rates when applied in well selected patients and performed by experienced teams.

26 April 2022 in Journal of Endovascular Therapy
Verified
Journal Article
Open access
RCRachel E. Clough
Rachel E. Clough
RSRafaëlle Spear
Rafaëlle Spear
JMJustine Mougin
Justine Mougin
THThomas Le Houérou
Thomas Le Houérou
DFDominique Fabre
Dominique Fabre
SHStéphan Haulon
Stéphan Haulon
Purpose: Fenestrated endovascular aneurysm repair (fEVAR) is established for the treatment of juxtarenal, pararenal, and thoracoabdominal aortic aneurysms (TAAAs). Bridging stents are used to connect the main body of the stent graft to the aortic branch vessels. Complications related to the bridging stents compromise the durability of the repair and require urgent re-intervention. Here we present the midterm results of the BeGraft stent graft system used for fEVAR. Materials and method: All consecutive patients treated with fEVAR and the current BeGraft Peripheral Stent Graft between November 2015 and September 2016 were included. Results: Thirty-nine consecutive patients (38 men) were enrolled and 101 BeGraft second-generation stent grafts were implanted. The median aneurysm diameter was 60 mm (54.5–67.0 mm). Aneurysms were juxtarenal and pararenal (19/39, 48.1%), type 4 TAAA (3/39, 7.7%), type 1, 2, and 3 TAAA (7/39, 17.8%), type 5 TAAA (4/39, 10.2%), and 15.4% (6/39) had a type I endoleak following a previous EVAR. Fifty-five BeGrafts were implanted in mesenteric arteries (22 in coeliac trunks, 31 in the superior mesenteric artery, and 2 in a hepatic or splenic artery) and 46 into renal arteries (24 right and 22 left). The renal artery diameters were 5, 6, 7, and 8 mm in 9, 7, 26, and 4 patients, respectively. Mesenteric arteries were exclusively stented with 9 and 10 mm diameter devices. The median follow-up was 33 months (IQ25 17–IQ75 36). During follow-up, 11 patients died (28%) from non–aneurysm-related causes. The overall patency rates for bridging stents were 98% and 97% at 1 and 2 years, respectively, with a freedom from secondary procedure rate on BeGraft stent grafts of 96% (97/101). All events occurred on stents implanted in renal arteries. Conclusion: Early favorable outcomes are confirmed during longer term follow-up. Vigilant surveillance is required.

28 August 2023 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
PNPetroula Nana
Petroula Nana
THThomas Le Houérou
Thomas Le Houérou
JGJulien Guihaire
Julien Guihaire
AGAntoine Gaudin
Antoine Gaudin
DFDominique Fabre
Dominique Fabre
SHStéphan Haulon
Stéphan Haulon
Introduction: Endovascular aortic arch repair using multibranch devices has been applied in patients considered at high risk for open repair. The aim of this case series was to report the early outcomes in patients managed with a new design 3 branch arch custom-made device, including a retrograde left common carotid artery (LCCA) branch. Methods: The Preferred Reporting Of CaSe Series in Surgery (PROCESS) guidelines were followed. All consecutive patients undergoing endovascular repair of an aortic arch lesion with a custom-made triple-branch device, including a retrograde LCCA branch (Cook Medical, Bloomington, IN, USA), between October 27, 2022, and February 28, 2023, were included. The presence of an arch aneurysm (degenerative or post-dissection) with diameter ≥55 mm and high risk for a conventional open repair set the indication for treatment. The primary outcomes were technical success and mortality at 30 days. Early morbidity and reinterventions were considered as secondary outcomes. Results: Eight elective patients (87.5% men, mean age 72.3±27.0 years) were included. Five of them (62.5%) had undergone a previous ascending aorta repair of an acute type A aortic dissection. All patients were asymptomatic, except one, with left recurrent laryngeal nerve compression. The mean maximum aortic diameter was 70.4±21.0 mm. Percutaneous femoral and axillary access was used in all cases except three in which a cut down for right carotid access was performed. Technical success was 100%. Femoral access to the LCCA and implantation of the bridging stent was performed without technical challenges. No death nor cerebrovascular event was recorded during the 30 day follow-up. Five patients (62.5%) presented major complications, 3 related to access needing reintervention and the remaining related to congestive heart failure (CHF), which were managed successfully with medical treatment. Follow-up (range 1–4 month) was uneventful, except for one patient who presented a secondary type Ia endoleak. Conclusions: According to our early experience, the presence of a retrograde branch facilitated the revascularization of the LCCA through femoral access, decreasing the risk of cerebrovascular morbidity. Further analyses with longer follow-up are needed to evaluate the safety and efficacy of the device. Clinical Impact: Data arising mainly from the retrograde branch for the revascularization of the LSA are encouraging from a variety of devices. The premiminary experience with a triple-branched arch device, with a retrograde branche for the LSA but also for the LCCA, was associated with no 30 day mortality and 100% technical success.The device’s design allowed swift catheterization and completion of the LCCA revascularization using femoral access exclusively.