Lennart J. Geurts

Lennart J. Geurts

Auto-generated profile, based on publicly available information

Lennart J. Geurts

From the Department of Radiology (J.W.B., T.v.d.B., L.J.G., A.M.d.H., T.W., J.J.M.Z., W.P.T.M.M., P.A.d.J., J.H.), University Medical Center Utrecht, Utrecht /University, the Netherlands

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2015 in NMR in Biomedicine
Verified
Journal Article
Open access
PDF file
WBW. H. Bouvy
W. H. Bouvy
LGL. J. Geurts
L. J. Geurts
HKH. J. Kuijf
H. J. Kuijf
PLP. R. Luijten
P. R. Luijten
LKL. J. Kappelle
L. J. Kappelle
JZJ. J. M. Zwanenburg
J. J. M. Zwanenburg
Thus far, blood flow velocity measurements with MRI have only been feasible in large cerebral blood vessels. High‐field‐strength MRI may now permit velocity measurements in much smaller arteries. The aim of this proof of principle study was to measure the blood flow velocity and pulsatility of cerebral perforating arteries with 7‐T MRI. A two‐dimensional (2D), single‐slice quantitative flow (Qflow) sequence was used to measure blood flow velocities during the cardiac cycle in perforating arteries in the basal ganglia (BG) and semioval centre (CSO), from which a mean normalised pulsatility index (PI) per region was calculated (n = 6 human subjects, aged 23–29 years). The precision of the measurements was determined by repeated imaging and performance of a Bland–Altman analysis, and confounding effects of partial volume and noise on the measurements were simulated. The median number of arteries included was 14 in CSO and 19 in BG. In CSO, the average velocity per volunteer was in the range 0.5–1.0 cm/s and PI was 0.24–0.39. In BG, the average velocity was in the range 3.9–5.1 cm/s and PI was 0.51–0.62. Between repeated scans, the precision of the average, maximum and minimum velocity per vessel decreased with the size of the arteries, and was relatively low in CSO and BG compared with the M1 segment of the middle cerebral artery. The precision of PI per region was comparable with that of M1. The simulations proved that velocities can be measured in vessels with a diameter of more than 80 µm, but are underestimated as a result of partial volume effects, whilst pulsatility is overestimated. Blood flow velocity and pulsatility in cerebral perforating arteries have been measured directly in vivo for the first time, with moderate to good precision. This may be an interesting metric for the study of haemodynamic changes in aging and cerebral small vessel disease. © 2015 The Authors NMR in Biomedicine Published by John Wiley & Sons Ltd.

1 January 2019 in Stroke
Verified
Journal Article
Open access
LGLennart J. Geurts
Lennart J. Geurts
JZJaco J.M. Zwanenburg
Jaco J.M. Zwanenburg
CKCatharina J.M. Klijn
Catharina J.M. Klijn
PLPeter R. Luijten
Peter R. Luijten
GBGeert Jan Biessels
Geert Jan Biessels
Background and Purpose—: Cerebral small vessel disease (SVD) is a major cause of stroke and dementia, but underlying disease mechanisms are still largely unknown, partly because of the difficulty in assessing small vessel function in vivo. We developed a method to measure blood flow velocity pulsatility in perforating arteries in the basal ganglia and semioval center. We aimed to determine whether this novel method could detect functional abnormalities at the level of the small vessels in patients with stroke attributable to SVD. Methods—: We investigated 10 patients with lacunar infarction (mean age 61 years, 80% men), 11 patients with deep intracerebral hemorrhage (ICH) considered to be caused by SVD (ICH, mean age 58 years, 82% men) and 18 healthy controls that were age- and sex-matched. We performed 2-dimensional phase contrast magnetic resonance imaging at 7 T to measure time-resolved blood flow velocity in cerebral perforating arteries of the semioval center and the basal ganglia. We compared the number of detected arteries, pulsatility index and mean velocity between the patient groups and controls. Results—: In the basal ganglia, the number of detected perforators was lower in lacunar infarction (26±9, P =0.01) and deep ICH patients (28±6, P =0.02) than in controls (35±7). The pulsatility index in the basal ganglia was higher in lacunar infarction (1.07±0.13, P =0.03), and deep ICH patients (1.02±0.11, P =0.11), than in controls (0.94±0.10). Observations in the semioval center were similar. Number of detected perforators was lower in lacunar infarction (32±18, P =0.06), and deep ICH patients (28±18, P =0.02), than in controls (45±16). The pulsatility index was higher in lacunar infarction (1.18±0.15, P =0.02), and deep ICH patients (1.17±0.14, P =0.045) than in controls (1.08±0.07). No velocity differences were detected. Conclusions—: This exploratory study shows that SVD can be expressed in terms of functional measures, such as pulsatility index, which are derived directly from the small vessels themselves. Future studies may use this technique to further unravel the mechanisms underlying SVD.

11 July 2017 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
LGLennart Geurts
Lennart Geurts
GBGeert Jan Biessels
Geert Jan Biessels
PLPeter Luijten
Peter Luijten
JZJaco Zwanenburg
Jaco Zwanenburg
Purpose: A previously published cardiac‐gated 2D Qflow protocol at 7 T in cerebral perforating arteries was optimized to reduce velocity underestimation and improve temporal resolution.Methods: First, the signal‐to‐noise ratio (SNR) gain of the velocity measurement (SNRv) was tested for two signal averages versus one. Second, the decrease in velocity underestimation with a tilted optimized nonsaturating excitation (TONE) pulse was tested. Third, the decrease in pulsatility index (PI) underestimation through improved temporal resolution was tested. Test‐retest agreement was measured for the resulting acquisition in older volunteers (mean age 63 years), and the results were compared with the other volunteers (mean age 26 years).Results: Using two signal averages increased SNRv by only 12% (P = 0.04), probably due to motion of the subvoxel‐size arteries. The TONE decreased velocity underestimation, thereby increasing the mean velocity from 0.52 to 0.67 cm/s (P < 0.001). The PI increased substantially with increasing temporal resolution. The test‐retest agreement showed good coefficients of repeatability of 0.18 cm/s for velocity and 0.14 for PI. The measured velocity was lower in the older group: 0.42 versus 0.51 cm/s (P = 0.05).Conclusions: The optimized sequence yields better velocity and PI estimates in small vessels, has twice as good test‐retest agreement, and has a suitable scan time for use in patients. Magn Reson Med 79:1473–1482, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.

1 May 2018 in NeuroImage
Verified
Journal Article
Open access
LGLennart J. Geurts
Lennart J. Geurts
ABAlex A. Bhogal
Alex A. Bhogal
JSJeroen Siero
Jeroen Siero
PLPeter R. Luijten
Peter R. Luijten
GBGeert Jan Biessels
Geert Jan Biessels
JZJaco J.M. Zwanenburg
Jaco J.M. Zwanenburg
Existing cerebrovascular reactivity (CVR) techniques assess flow reactivity in either the largest cerebral vessels or at the level of the parenchyma. We examined the ability of 2D phase contrast MRI at 7 T to measure CVR in small cerebral perforating arteries. Blood flow velocity in perforators was measured in 10 healthy volunteers (mean age 26 years) using a 7 T MR scanner, using phase contrast acquisitions in the semioval center (CSO), the basal ganglia (BG) and the middle cerebral artery (MCA). Changes in flow velocity in response to a hypercapnic breathing challenge were assessed, and expressed as the percentual increase of flow velocity as a function of the increase in end tidal partial pressure of CO2. The hypercapnic challenge increased (fit ± standard error) flow velocity by 0.7 ± 0.3%/mmHg in the CSO (P < 0.01). Moreover, the number of detected perforators (mean [range]) increased from 63 [27-88] to 108 [61-178] (P < 0.001). In the BG, the hypercapnic challenge increased flow velocity by 1.6 ± 0.5%/mmHg (P < 0.001), and the number of detected perforators increased from 48 [24-66] to 63 [32-91] (P < 0.01). The flow in the MCA increased by 5.2 ± 1.4%/mmHg (P < 0.01). Small vessel specific reactivity can now be measured in perforators of the CSO and BG, using 2D phase contrast at 7 T.

28 March 2024 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
JBjonas bartstra
jonas bartstra
TBT. van Den Beukel
T. van Den Beukel
GKG. Kranenburg
G. Kranenburg
LGL.J. Geurts
L.J. Geurts
AHA.M. Den Harder
A.M. Den Harder
WSWilko Spiering
Wilko Spiering
BACKGROUND AND PURPOSE: Carotid siphon calcification might contribute to the high prevalence of cerebrovascular disease in pseudoxanthoma elasticum through increased arterial flow pulsatility. This study aimed to compare intracranial artery flow pulsatility, brain volumes, and small-vessel disease markers between patients with pseudoxanthoma elasticum and controls and the association between arterial calcification and pulsatility in pseudoxanthoma elasticum. MATERIALS AND METHODS: Fifty patients with pseudoxanthoma elasticum and 40 age- and sex-matched controls underwent 3T MR imaging, including 2D phase-contrast acquisitions for flow pulsatility in the assessment of ICA and MCA and FLAIR acquisitions for brain volumes, white matter lesions, and infarctions. All patients with pseudoxanthoma elasticum underwent CT scanning to measure siphon calcification. Flow pulsatility (2D phase-contrast), brain volumes, white matter lesions, and infarctions (3D T1 and 3D T2 FLAIR) were compared between patients and controls. The association between siphon calcification and pulsatility in pseudoxanthoma elasticum was tested with linear regression models. RESULTS: Patients with pseudoxanthoma elasticum (mean age, 57 [SD, 12] years; 24 men) had significantly higher pulsatility indexes (1.05; range, 0.94–1.21 versus 0.94; range, 0.82–1.04; P = .02), lower mean GM volumes (597 [SD, 53] mL versus 632 [SD, 53] mL; P < .01), more white matter lesions (2.6; range, 0.5–7.5 versus 1.1; range, 0.5–2.4) mL; P = .05), and more lacunar infarctions (64 versus 8, P = .04) than controls (mean age, 58 [SD, 11] years; 20 men). Carotid siphon calcification was associated with higher pulsatility indexes in patients with pseudoxanthoma elasticum (β = 0.10; 95% CI, 0.01–0.18). CONCLUSIONS: Patients with pseudoxanthoma elasticum have increased intracranial artery flow pulsatility and measures of small-vessel disease. Carotid siphon calcification might underlie the high prevalence of cerebrovascular disease in pseudoxanthoma elasticum.