Restoration of the native glenohumeral anatomy is an important consideration in obtaining optimal range of motion (ROM) after anatomic total shoulder arthroplasty (TSA). Recently, a new stemless TSA system has been developed that uses both a multiplanar osteotomy (MPO), to improve the surgeon's ability to restore humeral center of rotation (COR), and an elliptical humeral head to improve ROM. The purpose of our study was to compare the difference in early postoperative ROM and restoration of radiographic COR, between this stemless TSA and standard stemmed TSAs. This was a retrospective review of 50 consecutive primary TSAs performed by a single surgeon for glenohumeral osteoarthritis. The initial cohort underwent TSA with a standard stemmed humeral component with a circular humeral head (n = 25), whereas the subsequent cohort underwent stemless TSA using an MPO and an elliptical humeral head (n = 25). Postoperative data collection included active shoulder ROM as measured by goniometer, complications or revision surgery, and measurements of radiographic COR. Patients were assessed at 6 weeks, 12 weeks, 6 months, and 12 months after surgery. Change in COR was determined on postoperative radiographs by 2 fellowship-trained surgeons on 2 separate occasions. Intra- and interrater reliability were computed using intraclass correlation coefficients. For both mean forward flexion (FF) and external rotation (ER), there was greater ROM in the MPO-elliptical group at all time points, which was statistically significant. Mean change in FF favored the MPO group at 6 and 12 weeks and was statistically significant and above the minimal clinically important difference (MCID): 6 weeks, standard -15.8° vs. MPO 8.4° (P = .004); 12 weeks, standard 6.4° vs. MPO 29.2° (P = .001). Mean change in ER favored the MPO group at 6 weeks and was statistically significant: standard 5.4° vs. MPO 14.0° (P = .02). There were no revision surgeries in either group. Average change in COR was 2.7 mm in the standard group and 1.8 mm in the MPO-elliptical group, which was statistically significant (P < .001). Number of patients with >3 mm of difference in COR was 10 (40%) in the standard group and 1 (5%) in the MPO-elliptical group, which was statistically significant (P = .002). Average intraclass correlation coefficient was 0.75, indicating good reliability within and between surgeon measurements. The use of a multiplanar osteotomy and elliptical humeral head was associated with improved early range of motion and better reproduction of the radiographic COR compared with standard stemmed TSA.
1 September 2021 in Seminars in Arthroplasty: JSES
Background: There is currently limited understanding of the contribution of glenoid version to postoperative internal (IR) and external rotation (ER) after reverse total shoulder arthroplasty (RTSA). The purpose of this study was to determine the impact of glenoid version on postoperative rotation after RTSA. Methods: Forty-five 3-dimensional (3D) computer models of human scapulae were created from de-identified computed tomography (CT) scans. The scapulae were divided into 3 separate groups based on glenoid version: normal (10° to -10°), moderate (-10 to -25°), and severe (< -25°). The scapulae then underwent virtual implantation with a Grammont-style RTSA prosthesis at either 0°, -20°, or -30° of retroversion based on the severity of the native glenoid version (normal, moderate, severe). Internal, external, and total rotation (TR) were determined for each construct at both 30° and 60° of humeral abduction. Results: Glenoids with a narrow width (< 25 mm) were noted to have minimal bony impingement on rotational testing and were excluded. In the remaining scapulae (n = 34), the achievable TR and IR for the humeral component decreased as glenoid retroversion increased. Changes in rotation for all categories were in general more pronounced at 60° of humeral abduction. Overall, ER generally increased as glenoid retroversion increased, with the largest increase occurring when going from 0° to -20° of retroversion, and minimal increase from -20° to -30° of retroversion regardless of humeral abduction. Conclusion: Placement of the glenoid component in increasing retroversion during RTSA results in a loss of IR and a corresponding increase in ER. Level of Evidence: Basic Science Study
1 January 2019 in Journal of Shoulder and Elbow Arthroplasty
Tranexamic acid (TXA) has been shown to be an effective modality to decrease blood loss in total shoulder arthroplasty (TSA). However, the most effective method of TXA administration remains controversial. The purpose of this study was to directly compare the use intravenous and topical TXA to determine which regimen was more effective in improving postoperative hemoglobin (Hb), transfusion rates, and patient outcomes after primary TSA. We conducted a retrospective review of 3 sequential cohorts of patients undergoing primary TSA with no TXA, intravenous TXA, or topical TXA. Postoperative data collection included daily Hb levels (g/dL), transfusions, thromboembolic events, length of stay, and discharge disposition. One-way analysis of variance was used to compare data between the 3 groups with post hoc Tukey honestly significant difference test for differences between pairs. Average change in Hb was 2.36 g/dL in the IV TXA group and 2.27 g/dL in the Topical TXA group which was not statistically significant (P = .69). Average change in Hb in the control group was 3.27 g/dL which was significant when compared to both TXA groups (P < .01). There were no transfusions or thromboembolic events in either TXA group. In the control group, there were 2 transfusions which was not statistically significant (P = .09). There was no significant difference in the discharge disposition or days in hospital between the 2 groups receiving TXA (P = .33). Intravenous and topical TXA are equivalent in improving postoperative Hb in TSA.
Cutibacterium acnes (formerly Propionibacterium acnes) is a significant pathogen in periprosthetic joint infections (PJIs) in total shoulder arthroplasty. Poor outcomes seen in PJIs are due to the established C. acnes bacterial biofilms. The prolonged nature of C. acnes infections makes them difficult to treat with antibiotics. The goal of this study was to determine the relative efficacy of vancomycin compared with penicillin and doxycycline against planktonic and mature biofilms. Clinical isolates from PJI patients as well as a laboratory strain of C. acnes were tested. Planktonic minimum inhibitory concentrations (MICs) and minimum bactericidal concentrations (MBCs) were obtained using modified clinical laboratory standard index assays. Biofilm MICs and MBCs were also obtained. The MIC was determined for both using the PrestoBlue viability stain. The MBC was determined using differential reinforced clostridial medium agar plates for colony-forming unit analysis. Using the PrestoBlue viability reagent, the planktonic MIC values for vancomycin were significantly higher than doxycycline. Across 10 strains of C. acnes, all three antibiotics had decreased efficacy when comparing planktonic and biofilm cultures. Although effective antibiotic doses ranged from 1 to 1,000 μg/mL, only doxycycline achieved inhibitory and bactericidal concentrations in all tested strains. Penicillin failed to achieve the minimum biofilm inhibitory concentration (MBIC) in 60% of tested strains, whereas vancomycin failed in 80% of tested strains. Penicillin, doxycycline, and vancomycin have similar abilities in inhibiting C. acnes growth planktonically. The MBIC for doxycycline was within the clinical dosing range, suggesting C. acnes biofilm offers minimal tolerance to these antibiotics. The MBIC for penicillin was within clinical dosing ranges in only 60% of trials, suggesting the relative tolerance of C. acnes to penicillin. The minimum biofilm bactericidal concentration (MBBC) of doxycycline showed efficacy in 90% of trials, whereas penicillin and vancomycin achieved MBBC in 15% of samples.
3 October 2022 in JSES Reviews, Reports, and Techniques