Alberto Guevara-Alvarez

Alberto Guevara-Alvarez

Auto-generated profile, based on publicly available information

Alberto Guevara-Alvarez

Instituto de Hombro IDH Hospital Angeles Querétaro Querétaro México

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2017 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
GSGernot Seppel
Gernot Seppel
TSTim Saier
Tim Saier
FMFrank Martetschläger
Frank Martetschläger
JPJohannes E. Plath
Johannes E. Plath
AGAlberto Guevara-Alvarez
Alberto Guevara-Alvarez
SBStefan Buchmann
Stefan Buchmann
Fractures of the humeral greater tuberosity (GT) are a frequent injury progressively treated with arthroscopic suture anchor repair. Yet, no biomechanical study has been performed comparing fixation strength of arthroscopic single- (SR) vs. double row (DR) fixation. Standardized fractures of the greater tuberosity were created in 12 fresh frozen proximal humeri. After random assignation to the SR or DR group the fixed humeri were tested applying cyclic loading to the supraspinatus and infraspinatus tendon. Load to failure and fragment displacement were assessed by means of an electrodynamic material testing machine using an optical tracking system. Load to failure values were higher in the DR group (649 N; ±176) than in the SR group (490 N; ±145) however without statistical significance (p = .12). In greater tuberosity displacement of 3–5 mm surgical treatment is recommended. The fixing constructs in this study did not reach displacement landmarks of 3 or 5 mm before construct failure as shown in previous studies. Thus the applied traction force (N) at 1 mm displacement was analyzed. In the SR group the load at 1 mm displacement was 277 N; ±46 compared to 260 N; ±62 in the DR group (p = .65). The results suggest that both techniques are viable options for refixation of greater tuberosity fractures. Level of Evidence: Laboratory study.

1 May 2025 in EFORT Open Reviews
Verified
Journal Article
Open access
PDF file
AGAlberto Guevara-Alvarez
Alberto Guevara-Alvarez
EVEdwin Valencia-Ramón
Edwin Valencia-Ramón
ALAlejandro Lopez-Villers
Alejandro Lopez-Villers
LNLuis Fernando Navarro-Pérez
Luis Fernando Navarro-Pérez
IGIsrael Gonzalez-Rizo
Israel Gonzalez-Rizo
Alexandre LädermannAlexandre Lädermann
Alexandre Lädermann
The long head of the biceps tendon (LHBT) has recently emerged as a therapeutic option for various shoulder pathologies. Synthetic materials and allografts have not shown sufficient resistance or favorable outcomes to restore rotator cuff native tissue properties, leading to consideration of using LHBT as biological augmentation. LHBT mimics adjacent structures, such as the rotator cuff, is easily accessible during surgery, and is a good source of live autologous cells for regenerative augmentation in rotator cuff repair, as a superior capsular reconstruction in irreparable cuff tears, in subscapularis augmentation in shoulder replacement and as a stabilizer in anterior shoulder instability. This narrative review aims to collect, synthesize and critically evaluate the literature on the use of the LHBT and its current applications in the field of shoulder surgery, improving the understanding of the terminology and consolidating the concepts related to the various procedures in shoulder surgery.

2 March 2015 in Journal of Hip Preservation Surgery
Verified
Journal Article
Open access
PDF file
AGAlberto Guevara-Alvarez
Alberto Guevara-Alvarez
NLNicholas Lash
Nicholas Lash
MBMartin Beck
Martin Beck
Arthroscopic over-resection of the head-neck junction during the treatment of a cam deformity can be a devastating complication and is difficult to treat. Large defects of the femoral head-neck junction (FHNJ) increase the risk of femoral neck fracture and can also affect hip biomechanics. We describe a case of an iatrogenic defect of the FHNJ due to excessive bone resection, and a previously non-described treatment using iliac crest autograft to restore femoral head-neck sphericity and hip joint stability. After protecting the femoral neck with an angled blade plate, the large anterior FHNJ defect was reconstructed using autogenous iliac crest bone graft; sphericity was restored by contouring the graft using spherical templates. Clinical and radiographic follow-up was performed up to 2 years. Results at 2 years showed no residual groin pain and normal range of motion. The Oxford Hip Score was 46/48, rated as excellent. Computed tomography (CT) scanning showed union of bone graft without resorption, and CT arthrogram indicating retained sphericity of the FHNJ without evidence of degenerative changes in the articular surface. This novel surgical technique can be used to restore the structural integrity and contour of the FHNJ that contains a significant anterior defect.

30 October 2023 in Arthroscopy Techniques
Verified
Journal Article
Open access
AGAlberto Guevara‐Alvarez
Alberto Guevara‐Alvarez
EVEdwin A. Valencia‐Ramon
Edwin A. Valencia‐Ramon
ALAlejandro Lopez‐Villers
Alejandro Lopez‐Villers
JVJorge Valadez‐Soto
Jorge Valadez‐Soto
FDFidel G. Dobarganes‐Barlow
Fidel G. Dobarganes‐Barlow
JNJorge Negrete‐Corona
Jorge Negrete‐Corona
Locked posterior shoulder dislocation (LPSD) is a rare condition often overlooked. In most cases, the humeral head remains stuck behind the glenoid, causing an impression fracture in 40% to 90% of LPSD cases, known as a reverse Hill‐Sachs lesion. The condition also affects the posterior capsulolabral complex and leads to the formation of scar tissue under the coracoid and subscapularis tendon, making it challenging to reduce without surgery. Although open treatment has been successful, it does not address the posterior capsulolabral complex. Arthroscopic‐assisted reduction provides a more detailed view and better exposure to the posterior structures. This article details a reproducible arthroscopic surgical technique for treating the locked dislocation and all intra‐articular pathology in a single‐stage procedure for patients with less than 25% reverse Hill‐Sachs bone loss. Technique Video: video See video under supplementary data.

22 August 2025 in Arthroscopy, Sports Medicine, and Rehabilitation
Verified
Journal Article
Open access
JAJavier Ardebol
Javier Ardebol
RERoger Erosa‐Villarreal
Roger Erosa‐Villarreal
EVEdwin Valencia‐Ramón
Edwin Valencia‐Ramón
ALAlejandro López‐Villers
Alejandro López‐Villers
GRGuillermo Franco‐Del Río
Guillermo Franco‐Del Río
AGAlberto Guevara‐Alvarez
Alberto Guevara‐Alvarez
Purpose: To determine the diagnostic performance and inter‐rater agreement for magnetic resonance imaging (MRI) signs of long head biceps tendon (LHBT) instability and overall, using conventional MRI for the diagnosis of biceps pulley lesions. Methods: In this retrospective analysis, conventional MRIs were reviewed by 5 assessors for the presence or absence of biceps pulley lesions and 6 specific MRI signs. Diagnostic performance of pulley lesion and sign detection using MRI was tested using arthroscopy as the reference standard. Interobserver agreement was measured with Kappa statistics and diagnostic performance with sensitivity, specificity, negative and positive predictive values overall and for radiologists and surgeons. Results: A total of 60 MRIs, 30 with biceps pully lesions and 30 without, were included. Overall, diagnostic performance metrics for MRI included a sensitivity of 81%, specificity of 79%, positive predictive value of 80%, and negative predictive value of 80%. Interobserver reliability analysis revealed moderate agreement overall, with a global kappa value of 0.59. LHBT angle showed the highest sensitivity (84%) and LHBT‐groove distance showed the greatest specificity (98%). Both radiologists and surgeons reported similar diagnostic accuracy through MRI. Conclusions: Overall, conventional MRI had an acceptable diagnostic performance, with sensitivity, specificity, and predictive values of approximately 80%. Among the evaluated signs, the LHBT angle had the highest sensitivity, whereas the LHBT‐groove distance showed the greatest specificity. Interobserver reliability was moderate overall, though some observer pairs achieved substantial agreement. However, there was variability across diagnostic signs. Level of Evidence: Level III, retrospective comparative study.

24 August 2026 in JSES Reviews, Reports, and Techniques
Verified
Journal Article
Open access
GVGuillermo Vera-Valencia
Guillermo Vera-Valencia
ABAsaf Bloch
Asaf Bloch
FAFernando Amaya-Aguilar
Fernando Amaya-Aguilar
EVEdwin Valencia-Ramón
Edwin Valencia-Ramón
ALAlejandro López-Villers
Alejandro López-Villers
AGAlberto Guevara-Álvarez
Alberto Guevara-Álvarez