Tobias H. Neuhann

Tobias H. Neuhann

Auto-generated profile, based on publicly available information

Tobias H. Neuhann

AaM Augenklinik am Marienplatz, Munich, Germany

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2015 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
TNTobias H. Neuhann
Tobias H. Neuhann
To evaluate long-term safety and efficacy of iStent trabecular micro-bypass stent implantation during cataract surgery in patients with primary open-angle, pseudo-exfoliation glaucoma, ocular hypertension, or secondary or post-traumatic glaucoma. AaM Augenklinik am Marienplatz, Munich, Germany. Prospective, open-label, non-randomized study. Preoperative and postoperative evaluations included intra-ocular pressure (IOP), topical ocular hypotensive medication use, cup/disc ratio, corrected-distance visual acuity (CDVA), complications, and adverse events. A single trabecular micro-bypass stent was implanted through the same temporal, limbal incision used for cataract surgery via phacoemulsification in a consecutive series of 62 eyes of 43 patients. To date, a total of 41 eyes have been followed for 3 years postoperatively, whereas long-term postoperative follow-up on the remaining patients is ongoing. Mean preoperative IOP was 24.1 ± 6.9 mm Hg on a mean of 1.8 medications (±0.9). Analyses of eyes with no secondary surgical intervention showed mean IOP reduction to 14.8 ± 4.2 mm Hg at 12 months (n = 61), 14.5 ± 2.2 mm Hg at 24 months (n = 42), and 14.9 ± 2.3 mm Hg at 36 months (n = 39). Medications were eliminated in 74% of eyes at 36 months. Five eyes, 4 with previous glaucoma surgeries and 1 with pseudo-exfoliation syndrome, required additional glaucoma surgery after stent implantation. No intra-operative or postoperative complications typically seen with conventional glaucoma surgeries occurred after stent implantation. At 36 months, CDVA was 20/40 or better in 38 eyes (93%). Trabecular micro-bypass stent implantation during cataract surgery was safe and effective in patients with ocular hypertension or glaucoma as measured by a sustained reduction in IOP and medication use and an excellent safety profile through 3 years after surgery. Dr. Neuhann has no financial or proprietary interest in any material or method mentioned. Glaukos Corp. provided editorial assistance in the preparation of the manuscript.

1 March 2019 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Open access
TNTobias H. Neuhann
Tobias H. Neuhann
DHDana M. Hornbeak
Dana M. Hornbeak
RNRaphael T. Neuhann
Raphael T. Neuhann
JGJane Ellen Giamporcaro
Jane Ellen Giamporcaro
To assess 5-year outcomes after implantation of 1 trabecular microbypass stent during cataract surgery in eyes with open-angle glaucoma (OAG) or ocular hypertension. Private ophthalmology clinic (AaM Augenklinik am Marienplatz, Munich, Germany). Prospective nonrandomized consecutive case series. One trabecular microbypass stent was implanted after phacoemulsification cataract surgery by one surgeon over 4 years. Evaluations included intraocular pressure (IOP), medications, corrected distance visual acuity, cup-to-disc ratio, complications, and adverse events. This case series included 65 eyes of 43 patients with OAG (including primary, n = 39; pseudoexfoliative, n = 14; secondary uveitic, n = 1; posttraumatic, n = 1) or ocular hypertension (n = 10). Thirty-eight percent of eyes had previous trabeculectomy and/or glaucoma laser procedures, and 68% were on 2 or more preoperative medications. Twenty-six eyes completed follow-up through 5 years, and follow-up is ongoing. Among eyes without additional glaucoma surgery, the mean year 5 IOP decreased by 38% to 14.7 mm Hg ± 3.0 (SD) versus 23.7 ± 7.4 mm Hg preoperatively; 92% of eyes had a mean year 5 IOP of 18 mm Hg or lower and 65% had an IOP of 15 mm Hg or lower. Medications were reduced by 75% to 0.5 ± 0.9 medications versus 2.0 ± 1.0 preoperatively, with 4% of eyes on 3 to 4 medications versus 28% preoperatively, and 69% medication-free versus 5% preoperatively. The mean IOP at all postoperative visits was 16.0 mm Hg or lower and the mean medication number was 0.5 or less. Safety was favorable throughout the follow-up. In a real-life cohort of eyes with OAG or ocular hypertension, substantial, durable, and safe IOP and medication reductions were achieved through 5 years after trabecular microbypass stent implantation with cataract surgery.

21 June 2024 in Ophthalmology and Therapy
Verified
Journal Article
Open access
PDF file
TNTobias H. Neuhann
Tobias H. Neuhann
RNRaphael T. Neuhann
Raphael T. Neuhann
DHDana M. Hornbeak
Dana M. Hornbeak
Introduction This study evaluated 10-year results of implanting one iStent trabecular micro-bypass stent during cataract surgery in eyes with open-angle glaucoma (OAG) or ocular hypertension. Methods This retrospective, non-randomized study examined 10-year outcomes of iStent trabecular micro-bypass stent implantation with cataract surgery by one surgeon in eyes with OAG [including primary OAG (POAG) and pseudoexfoliative glaucoma (PXG)] or ocular hypertension at a multi-specialty German ophthalmology center. Study visits were conducted preoperatively and at 2.5, 3, 5, and 10 years postoperatively; examinations included intraocular pressure (IOP), medications, corrected-distance visual acuity (CDVA), and adverse events. Results A total of 63 eyes of 45 patients with OAG (n = 60 eyes) or ocular hypertension (n = 3 eyes) and data through 10 years were analyzed. Mean preoperative IOP was 18.6 ± 4.4 mmHg on 1.83 ± 1.03 mean medications. At study visits through 10 years postoperative, mean IOP reduced by 12.9–19.0% (p < 0.005 at all points), and mean medication burden reduced by 37.8–51.4% (p ≤ 0.006 at all points). At 10 years postoperatively, 77.8% of eyes had IOP ≤ 18 mmHg and 47.6% had IOP ≤ 15 mmHg (vs. 50.8% and 25.4% preoperatively, respectively; p = 0.016). One-third (33.3%) of eyes were medication-free vs. 3.2% preoperatively (p < 0.001); 17.5% were on 2–5 medications (vs. 55.6% preoperatively, p = 0.005); and 93.7% of eyes were on the same or fewer medications vs. preoperative. Post-phacoemulsification CDVA improvement was maintained; no filtering surgeries were completed over 10-year follow-up. Conclusions Significant and safe IOP and medication reductions were observed through 10 years after iStent implantation with cataract surgery in patients with OAG or ocular hypertension.