Recently a point mutation (G1691A) in the coagulation factor V gene was shown to cause resistance for cleavage by activated protein C.The mutation is associated with an increased thrombotic risk and thus- far the most common genetic cause of thrombophilia.Current techniques to investigate the single base pair mutation at the DNA level use an assay based upon the polymerase chain reaction followed by restriction enzyme digestion or Southern blotting and allele specific probing.The method we describe here consists of a single PCR in which two specially designed allele specific primers and two consensus primers were used in one reaction to distinguish between homozygous normal,heterozygous and homozygous mutant individuals.Amplification products were analysed using Capillary Electrophoresis and on line UV monitoring. The Allele Specific Amplification Protocol and subsequent CE analysis (ASAP-CE) is a convenient,fast,automated and highly reproducible method that can be used in a routine laboratory setting.
Homocysteine may have an effect on risk of cardiovascular disease by stimulating procoagulant factors and/or impair anti-coagulant mechanisms or fibrinolysis. However, data in humans of such effects are sparse. In this intervention study, we examined the effect of homocysteine lowering by B-vitamin supplementation on prothrombin fragments 1 and 2 (F1+2), thrombin-antithrombin complex (TAT), and fibrin degradation products (D-dimer). The study comprised 118 healthy volunteers, 50 with homocysteine > 16 µmol/L and 68 with homocysteine ≤ 16 µmol/L, who were randomized to placebo or highdose B-vitamin supplements (5 mg folic acid, 0.4 mg hydroxycobalamin, and 50 mg pyridoxine) daily for 8 weeks. Although homocysteine concentrations were 27.7% (p < 0.0001) reduced in the Bvitamin group compared to the placebo group, no effect on F1+2 and TAT concentrations was observed. A 10.4% reduction was observed for D-dimer (p = 0.08). In conclusion, it appears that in healthy subjects homocysteine reduction by B-vitamin supplementation has a modest beneficial effect on clotting activation.
The accurate detection and quantification of coagulation inhibitors remains a challenging problem for most diagnostic laboratories. Prolonged screening assays and abnormal results of mixing tests with normal plasma may indicate the presence of such inhibitors. Yet, the presence of lupus anticoagulant, heparin, and potential contamination of plasma with therapeutically active antithrombotic drugs has to also be ruled out. This review covers the epidemiology of acquired functional coagulation inhibitors, and reports the results of a wet-workshop, organized by the External Quality Control for Assays and Test (ECAT) Foundation, on laboratory detection of such inhibitors. The aim of the workshop was to investigate, within groups of experts from dispersed professional laboratories, the quality of inhibitor detection and the difficulties encountered during the analytical process. In this workshop 8 samples representing varying milieu were tested by 10 groups of participants from 20 different countries. Workshop participants were asked to report the results of all investigations performed and to provide a likely diagnosis and/or a conclusion of the hemostasis abnormality represented by the test samples. Generally, the sensitivity of inhibitor detection was high but the differential diagnosis of the type of inhibitors identified was unsatisfactory, as many false-positive and false-negative results were observed. The most remarkable observation was the lack of a clear step-by-step analysis of the nature of an inhibitor once a positive mixing test had been detected. The possible consequences of these observations for the appropriate diagnosis and clinical management of patients are outlined. A diagnostic algorithm for the differential diagnosis and confirmation of acquired coagulation inhibitors is presented.