1 January 2018 in Advances in Civil Engineering
Soil slope diseases in seasonally frozen regions are mostly related to water migration and frost heave deformation of the soil. Based on the partial differential equation defined using the COMSOL Multiphysics software, a thermo‐hydromechanical coupling model considering water migration, ice‐water phase change, ice impedance, and frost heave is constructed, and the variations in the temperature field, migration of liquid water, accumulation of solid ice, and deformation of frost heave in frozen soil slopes are analysed. The results show that the ambient temperature has a significant effect on the temperature and moisture field of the slope in the shallow area. In addition, the degree of influence gradually weakens from the outside to the inside of the slope, and the number of freeze‐thaw cycles in deep soil is less than that in shallow soil. During the freezing period, water in the unfrozen area rapidly migrates to the frozen area, and the total moisture content abruptly changes at the vicinity of the freezing front. The maximum frozen depth is the largest at the slope top and the smallest at the slope foot. During the melting period, water is enriched at the melting front with the frozen layer melting; the slope is prone to shallow instability at this stage. The melting of the frozen layer is bidirectional, so the duration of slope melting is shorter than that of the freezing process. The slope displacement is closely related to the change in temperature—a relation that is in agreement with the phenomenon of thermal expansion and contraction in unfrozen areas and reflects the phenomenon of frost heave and thaw settlement in frozen areas.
1 January 2019 in Advances in Civil Engineering
In order to evaluate the traffic‐load‐induced cumulative deformation of road high liquid limit subgrade soil, a series of laboratory tests are performed to determine the physical and mechanical properties of high liquid limit soil. A cumulative deformation model is then developed with consideration of the effects of dynamic deviator stress, the number of repeated loadings, and the material properties of subgrade soil. Based on Lu’s vehicle‐road‐ground coupling model, the traffic‐load‐induced stress, which is very important in predicting cumulative settlement of the subgrade, is calculated explicitly. The layerwise summation method is used to evaluate the traffic‐load‐induced cumulative deformation. Moreover, a parametric study is conducted using numerical computation and the results show that the traffic‐load‐induced cumulative deformation is mainly generated from the shallow soil, and the additional dynamic load plays an important role in analyzing the traffic‐load‐induced settlement.
10 July 2013 in Journal of Central South University
19 December 2014 in Earthquake Engineering and Engineering Vibration
1 January 2014 in Advances in Materials Science and Engineering
A shaking table model test was carried out to develop an understanding of the performance improvement of saturated silty soil ground using stone column composite foundation as reinforcement. It is found that at less than 0.161 g loading acceleration, soil between piles has not yet been liquefied, the response acceleration scarcely enlarges, and the shear displacement almost does not appear in silty soil. At 0.252 g loading acceleration, as a result of liquefaction of soil between piles, the response acceleration increases rapidly and reaches its peak, and the shear displacement of silty soil increases significantly. At 0.325 g loading acceleration, the integral rigidity of foundation decreases greatly, which reduces its capability of vibration transmission and result in the response acceleration amplification coefficient is less than that at the former loading acceleration, but the shear displacement of silty soil further increases. The stone column composite foundation can greatly reduce both the shear displacement and the settlement of ground compared with untreated foundation. Under the condition of 7-degree seismic fortification, the design meets seismic resistance requirements.