In this paper, the efficiency of a 2.75 MW nacelle drivetrain on a test bench was determined traceably at various load points. For this purpose, so-called transfer standards for mechanical and electrical power measurement were additionally installed and integrated into the nacelle drivetrain. As torque measurement contributes greatly to the overall uncertainty, the static torque calibration was expanded to include additional influences present under rotation. An overall system efficiency of 89% was measured in the high torque and high speed range. The relative expanded measurement uncertainty for efficiency determination was between 0.30% and 0.72% over the entire operating range. Both the efficiency and the relative expanded measurement uncertainty were calculated for each operating point.
17 April 2019 in Journal of Sensors and Sensor Systems
To determine the efficiency of multi-MW wind turbines, the torque measurement in wind turbine test benches has to be performed with an accuracy better than 0.2 %. To this end, the torque measurement has to be traced to national standards in the MN m range. This can be done by using a novel torque transfer standard in combination with a newly developed torque calibration procedure under constant rotation, which are both presented and discussed in this paper. The calibration procedure was performed on a 4 MW wind turbine test bench and the evaluation of the calibration result, including a measurement uncertainty, is explained in detail.
1 August 2018 in Journal of Physics: Conference Series
For torque transducers above 1.1 MNm, no traceable measurement has been possible to date. Therefore, an extrapolation method deploying measurement data from partial ranges is to be developed. Both partial and full range measurements up to 20 kN m are performed to gather data for implementing an extrapolation approach. The extrapolated data is evaluated, and the results are compared to the full range results.
The article provides an analysis of the metrological properties of a 5 MN·m torque transducer. The relative electrical signal (given in electrical units, mV/V) as a function of torque measured in both the clockwise and anticlockwise directions was monitored. To fit the data, the weighted method of least squares with both a straight-line and a cubic spline curve was used. The results of the analysis indicated that the straight-line fitting method produced smaller values of expanded uncertainty than the cubic spline fitting method. Additionally, the study confirmed the assumptions that the Monte Carlo method for propagating uncorrelated distributions was more accurate than the uncertainty propagation method, regardless of the type of curve fitting used. From the estimated uncertainty coverage corridor at selected measurement points, confidence intervals–expanded uncertainties were determined. Additionally, the fuzzy sets approach to the evaluation of uncertainty was presented, and the approximate value of the expanded uncertainty was calculated.
This paper discusses the problem of determining the zero point when measuring torque under rotation. Two approaches are presented and analysed: static zero signal determination, which should be used for efficiency calculation, and rotational zero signal determination, which should be used for test bench torque calibration under rotation.
The current torque calibration range up to 1.1 MN·m is not any longer sufficient. The fast growing wind energy sector raised the demand for traceability of torque in the MN·m range over the last few years. To this end, a 5 MN·m torque transducer was acquired to extend the torque calibration range. Since the measuring device cannot be calibrated over its full measurement range, mathematical methods to forecast the behaviour of the torque transducer above 1.1 MN·m and their further development are presented.