Markus Wolfgang Scheppach

Markus Wolfgang Scheppach

Auto-generated profile, based on publicly available information

Markus Wolfgang Scheppach

Internal Medicine III – Gastroenterology, University Hospital of Augsburg, Augsburg, Germany

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2022 in Gut
Verified
Journal Article
Open access
PDF file
AEAlanna Ebigbo
Alanna Ebigbo
RMRobert Mendel
Robert Mendel
MSMarkus W Scheppach
Markus W Scheppach
APAndreas Probst
Andreas Probst
NSNeal Shahidi
Neal Shahidi
HMHelmut Messmann
Helmut Messmann
In this study, we aimed to develop an artificial intelligence clinical decision support solution to mitigate operator-dependent limitations during complex endoscopic procedures such as endoscopic submucosal dissection and peroral endoscopic myotomy, for example, bleeding and perforation. A DeepLabv3-based model was trained to delineate vessels, tissue structures and instruments on endoscopic still images from such procedures. The mean cross-validated Intersection over Union and Dice Score were 63% and 76%, respectively. Applied to standardised video clips from third-space endoscopic procedures, the algorithm showed a mean vessel detection rate of 85% with a false-positive rate of 0.75/min. These performance statistics suggest a potential clinical benefit for procedure safety, time and also training.

5 February 2025 in Endoscopy
Verified
Journal Article
Closed access
PDF file
MSMarkus Wolfgang Scheppach
Markus Wolfgang Scheppach
RMRobert Mendel
Robert Mendel
AMAnna Muzalyova
Anna Muzalyova
DRDavid Rauber
David Rauber
APAndreas Probst
Andreas Probst
AEAlanna Ebigbo
Alanna Ebigbo
While artificial intelligence (AI) shows high potential in decision support for diagnostic gastrointestinal endoscopy, its role in therapeutic endoscopy remains unclear. Third-space endoscopic procedures pose the risk of intraprocedural bleeding. Therefore, we aimed to develop an AI algorithm for intraprocedural blood vessel detection.Using a test dataset of 101 standardized video clips containing 200 predefined submucosal blood vessels, 19 endoscopists were evaluated for vessel detection rate (VDR) and time (VDT) with and without support of an AI algorithm. Endoscopists were grouped according to experience in endoscopic submucosal dissection.With AI support, endoscopist VDR increased from 56.4% (95%CI CI 54.1–58.6) to 72.4% (95%CI CI 70.3–74.4). Endoscopist VDT dropped from 6.7 seconds (95%CI 6.2–7.1) to 5.2 seconds (95%CI 4.8–5.7). False-positive readings appeared in 4.5% of frames and were marked for a significantly shorter time than true positives (0.7 seconds [95%CI 0.55–0.87] vs. 6.0 seconds [95%CI 5.28–6.70]).AI improved the VDR and VDT of endoscopists during third-space endoscopy. While these data need to be corroborated by clinical trials, AI may prove to be an invaluable tool for improving safety and speed of endoscopic interventions.

10 May 2025 in Medical Image Analysis
Verified
Journal Article
Closed access
HWHongyu Wang
Hongyu Wang
YLYonghao Long
Yonghao Long
YCYueyao Chen
Yueyao Chen
HYHon-Chi Yip
Hon-Chi Yip
MSMarkus Scheppach
Markus Scheppach
QDQi Dou
Qi Dou

7 January 2025 in Endoscopy International Open
Verified
Journal Article
Open access
PDF file
MSMarkus Wolfgang Scheppach
Markus Wolfgang Scheppach
HYHon Chi Yip
Hon Chi Yip
YCYueyao Chen
Yueyao Chen
HYHongzheng Yang
Hongzheng Yang
JCJianfeng Cao
Jianfeng Cao
PCPhilip Wai Yan Chiu
Philip Wai Yan Chiu
Endoscopic submucosal dissection (ESD) is a challenging minimally invasive resection technique with a long training period and relevant operator-dependent complications. Real-time artificial intelligence (AI) orientation support may improve safety and intervention speed.A total of 1011 endoscopic still images from 30 ESDs were annotated for relevant anatomical structures and used for training of a deep learning algorithm. After internal and external validation, this algorithm was applied to 12 ESDs performed by either one expert or one novice in ESD using an in vivo porcine model.External validation yielded mean Dice Scores of 88%, 60%, 58%, and 92% for background, submucosal layer, submucosal blood vessels, and muscle layer, respectively. The system was successfully applied during all 12 ESDs. All resections were completed en bloc and without complications.In this proof-of-concept study, feasibility of a real-time AI algorithm for anatomical structure delineation and orientation support during ESD was evaluated. The application proved safe and appropriate for routine procedures in humans. Further studies are needed to elucidate a potential clinical benefit of this new technology.

7 January 2025 in Endoscopy International Open
Verified
Journal Article
Open access
PDF file
SCShannon Melissa Chan
Shannon Melissa Chan
DCDaniel Chan
Daniel Chan
HYHon Chi Yip
Hon Chi Yip
MSMarkus Wolfgang Scheppach
Markus Wolfgang Scheppach
RLRay Lam
Ray Lam
PCPhilip Wai Yan Chiu
Philip Wai Yan Chiu
Completeness of esophagagogastroduodenoscopy (EGD) varies among endoscopists, leading to a high miss rate for gastric neoplasms. This study aimed to determine the effect of the Cerebro real-time artificial intelligence (AI) system on completeness of EGD for endoscopists in early stages of training.The AI system was built with CNN and Motion Adaptive Temporal Feature Aggregation (MA-TFA). A prospective sequential cohort study was conducted. Endoscopists were taught about the standardized EGD protocol to examine 27 sites. Then, each subject performed diagnostic EGDs per protocol (control arm). After completion of the required sample size, subjects performed diagnostic EGDs with assistance of the AI (study arm). The primary outcome was the rate of completeness of EGD. Secondary outcomes included overall inspection time, individual site inspection time, completeness of photodocumentation, and rate of positive pathologies.A total of 466 EGDs were performed with 233 in each group. Use of AI significantly improved completeness of EGD [mean (SD) (92.6% (6.2%) vs 71.2% (16.8%)]; P <0.001 (95% confidence interval 19.2%–23.8%, SD 0.012). There was no difference in overall mean (SD) inspection time [765.5 (338.4) seconds vs 740.4 (266.2); P=0.374]. Mean (SD) number of photos for photo-documentation significantly increased in the AI group [26.9 (0.4) vs 10.3 (4.4); P <0.001]. There was no difference in detection rates for pathologies in the two groups [8/233 (3.43%) vs 5/233 (2.16%), P=0.399].Completeness of EGD examination and photodocumentation by endoscopists in early stages of are improved by the AI-assisted software Cerebro.

8 October 2024 in Endoscopy
Verified
Journal Article
Closed access
PDF file
CRChristoph Römmele
Christoph Römmele
MAMousa Ayoub
Mousa Ayoub
JWJulia Wanzl
Julia Wanzl
VTVidan Tadic
Vidan Tadic
GBGeorg Braun
Georg Braun
AEAlanna Ebigbo
Alanna Ebigbo
The trend toward disposable products in gastrointestinal endoscopy, including single-use endoscopes, remains undeterred, even though crucial questions of sustainability and performance have not been sufficiently studied. The first single-use therapeutic gastroscope was recently approved in Europe, but clinical data to support its use are currently lacking. We aimed to evaluate the performance of this novel device in routine procedures requiring a large working channel.Between January and May 2024, consecutive patients with an indication for therapeutic gastroscopy were included prospectively. The primary outcome was intraprocedural technical success rate.Eight gastrointestinal bleedings, two pancreatic necrosectomies, four foreign body removals, four stent placements, and two cryo-balloon ablations were performed. The technical success rate was 84% (16/19 patients). Crossover to a standard endoscope was required in three procedures. Clinical success was achieved in all cases with technical success. Overall user experience was 3.2 on a Likert scale of 1–5. No adverse events were reported.The single-use therapeutic gastroscope demonstrated feasibility in various therapeutic procedures; however, a 16% crossover rate and fair user assessment score suggest that further technical improvements to the device are necessary.