We have deduced the structure of the bromobenzene–I 2 heterodimer and the (bromobenzene) 2 homodimer inside helium droplets using a combination of laser-induced alignment, Coulomb explosion imaging (CEI), and three-dimensional ion imaging. The complexes were fixed in a variety of orientations in the laboratory frame, then in each case multiply ionized by an intense laser pulse. A three dimensional ion imaging detector, including a Tpx3Cam detector allowed us to measure the correlations between velocity vectors of different fragments and, in conjunction with classical simulations, work backward to the initial structure of the complex prior to explosion. For the heterodimer, we find that the I 2 molecular axis intersects the phenyl ring of the bromobenzene approximately perpendicularly. The homodimer has a stacked parallel structure, with the two bromine atoms pointing in opposite directions. These results illustrate the ability of CEI to determine the structure of large complexes, and point the way toward real-time measurements of bimolecular reactions inside helium droplets.
Alkali trimers, Ak3, located on the surface of He nanodroplets are triply ionized following multiphoton absorption from an intense femtosecond laser pulse, leading to fragmentation into three correlated Ak+ ions. Combining the information from threefold covariance analysis of the emission direction of the fragment ions and their kinetic energy distributions P(Ekin), we find that Na3, K3, and Rb3 have an equilateral triangular structure, corresponding to that of the lowest lying quartet state A2′4, and determine the equilibrium bond distance Req(Na3) = 4.65 ± 0.15 Å, Req(K3) = 5.03 ± 0.18 Å, and Req(Rb3) = 5.45 ± 0.22 Å. For K3 and Rb3, these values agree well with existing theoretical calculations, while for Na3, the value is 0.2–0.3 Å larger than the existing theoretical results. The discrepancy is ascribed to a minor internuclear motion of Na3 during the ionization process. In addition, we determine the distribution of internuclear distances P(R) under the assumption of fixed bond angles. The results are compared to the square of the internuclear wave function |Ψ(R)|2.
Recently, it was shown how the primary steps of solvation of a single Na+ ion, instantly created at the surface of a nanometer-sized droplet of liquid helium, can be followed at the atomic level [Albrechtsen et al., Nature 623, 319 (2023)]. This involved measuring, with femtosecond time resolution, the gradual attachment of individual He atoms to the Na+ ion as well as the energy dissipated from the local region of the ion. In this current work, we provide a more comprehensive and detailed description of the experimental findings of the solvation dynamics and present an improved Poisson-statistical analysis of the time-resolved yields of the Na+Hen ions recorded. For droplets containing an average of 5200 He atoms, this analysis gives a binding rate of 1.84 ± 0.09 atoms/ps for the binding of the first five He atoms to the Na+ ion. In addition, thanks to accurate theoretical values for the evaporation energies of the Na+Hen ions, obtained by path integral Monte Carlo methods using a new potential energy surface presented here for the first time, we improve the determination of the time-dependent removal of the solvation energy from the region around the sodium ion. We find that it follows Newton’s law of cooling for the first 5 ps. Measurements were carried out for three different average droplet sizes, ⟨ND⟩ = 9000, 5200, and 3600 helium atoms, and differences between these results are discussed.
19 November 2025 in Physical Chemistry Chemical Physics
We present the design of a VMI spectrometer optimized for attosecond spectroscopy in the 0–40 eV energy range. It is based on a compact three-electrode configuration where the lens shape, size, and material have been optimized using numerical simulations to improve the spectral resolution by a factor of ∼5 relative to the initial design [Eppink and Parker, Rev. Sci. Instrum. 68, 3477–3484 (1997)] while keeping a flat spectral response in the 10–40 eV range. The experimental performance is tested using an attosecond source based on high-order harmonic generation. A good agreement is observed between the measured and simulated spectral resolution. At low kinetic energy, the electrostatic lens remains the limiting factor, while the high energy range is mostly affected by the resolution of the camera objective.