Tong Zhang

Tong Zhang

Auto-generated profile, based on publicly available information

Tong Zhang

Cardiff University, Cardiff, U.K.

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2024 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Open access
TZTong Zhang
Tong Zhang
MQMeysam Qadrdan
Meysam Qadrdan
JWJianzhong Wu
Jianzhong Wu
BCBenoit Couraud
Benoit Couraud
MSMartin Stringer
Martin Stringer
GSGoran Strbac
Goran Strbac

1 May 2014
Verified
Conference Paper
Closed access
TZTong Zhang
Tong Zhang
MFMinfan Fu
Minfan Fu
CMChengbin Ma
Chengbin Ma
XZXinen Zhu
Xinen Zhu
Wireless power transfer to multiple devices is of great importance to simultaneous charging mobile devices, where coupling system is crucial component determining system efficiency. In a multiple-receiver system, external loads values would affect the coupling efficiency, especially for low quality factor coupling system. In this paper, a two-receiver model is proposed to analysis the optimal external loads that would maximize the coupling efficiency. Optimal loads formulas for a two-receiver system are derived using circuit model and validated using a 13.56MHz printed circuit board coupling system.

2 December 2022 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
TZTong Zhang
Tong Zhang
NHNicolas Hanousek
Nicolas Hanousek
MQMeysam Qadrdan
Meysam Qadrdan
Reza AhmadianReza Ahmadian
Reza Ahmadian
With the global trend to exploit more renewable energy sources, tidal range energy has been gaining more attention recently. This power generation technology is expected to reduce the share of fossil fuels and provide flexibility to the power system. With a pioneering tidal range generation project just granted in Wales and more proposals planned in Great Britain, it is important to study how the incorporation of multiple tidal range power stations will affect power system operation. In this paper, the role of tidal range energy generation in the future Great Britain power system is investigated based on a day-ahead scheduling model of power system incorporating multiple tidal range power stations. In the proposed model, tidal range power stations situated at different sites operate flexibly and in coordination, supporting the power system to reach the minimum operating cost. A case study based on the Great Britain electricity transmission system in 2030 with one tidal barrage and one tidal lagoon was investigated. The results showed that the coordination of flexible tidal range power stations can reduce the power system's operating cost. Furthermore, the energy-storage feature of tidal range power stations can act as a stable source of flexibility in the power system.

18 May 2023 in IEEE Transactions on Energy Markets, Policy and Regulation
Verified
Journal Article
Closed access
QCQikun Chen
Qikun Chen
TZTong Zhang
Tong Zhang
MQMeysam Qadrdan
Meysam Qadrdan
In the Great Britain's high-pressure gas transmission network, there are 24 gas compressor stations with 68 operational compressor units of different types and sizes. As of 2021, the aggregate capacity of electric-driven gas compressors was 200 MW. By using linepack as a form of gas storage buffer, the compressors can be operated flexibly to achieve a minimum operational cost under fluctuating electricity prices. Furthermore, since electricity consumed by electric-driven compressors can affect the balance of the power grid, the ability of electric-driven compressor units to regulate their electricity consumption is useful to be quantified. In this paper, the value of flexibility from the hybrid compressor stations (compressor stations in which both electric-driven and gas-driven compressor units exist) is analysed. The operation of the high-pressure gas network in Great Britain was formulated as a Mixed-Integer Second Order Cone Programming (MISOCP) problem. The modelling results show that employing the flexibility from hybrid compressor stations in the gas network can reduce more than 20% of the operational cost and 50% of emissions from the compressor fleet. Furthermore, a cost-benefit analysis was carried out to assess the investment viability of installing electric-driven compressor units. It is demonstrated that the economic feasibility of investing in electric-driven compressors is sensitive to the future carbon price.

2 June 2026 in Applied Energy
Verified
Journal Article
Open access
ZZZhengrun Zhao
Zhengrun Zhao
Kang LiKang Li
Kang Li
TZTong Zhang
Tong Zhang
SZShihao Zhao
Shihao Zhao