Peter Olugbenga Omotainse

Peter Olugbenga Omotainse

Auto-generated profile, based on publicly available information

Peter Olugbenga Omotainse

Department of Agriculture and Bioresources Engineering, Federal University of Agriculture, Abeokuta, Nigeria

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2026 in Kurdistan Journal of Applied Research
Verified
Journal Article
Open access
PDF file
SOSamuel Oluyemi Owoeye
Samuel Oluyemi Owoeye
FDFolasade Durodola
Folasade Durodola
SASikirulahi Abdulkareem
Sikirulahi Abdulkareem
OOOlugbenga Omotainse
Olugbenga Omotainse
Earlier cracks identification is very crucial in structural building maintenance as it is the main signifier of building deterioration. Manual inspection processes are slow, expensive and can be easily compromised by human error. Though the You Only Look Once version 8 (YOLOv8) has emerged as a powerful framework for automated crack detection, it faces limitations in accurately detecting small, irregularly shaped, and partially obscured cracks due to feature loss in deeper network layers and insufficient pixel-level precision. This study addresses these limitations by strategically integrating five attention mechanisms into YOLOv8's architecture: Convolutional Block Attention Module (CBAM), Efficient Channel Attention (ECA), Selective Kernel Attention (SKA), Shuffle Attention (SA), and Global Attention Mechanism (GAM). The attention modules were placed at critical positions within the backbone and neck regions to enhance feature representation without compromising computational efficiency. Using a comprehensive dataset of 13,169 building crack images with 19,386 annotations, each attention-enhanced variant was trained and evaluated against the baseline YOLOv8 model. Results demonstrate consistent improvements across all attention mechanisms. CBAM achieved the highest segmentation accuracy with mask mean Average Precision (mAP) @0.5 of 0.820 (0.4% improvement), while ECA provided the most parameter-efficient enhancement, improving box precision by 3.5% with only 41 additional parameters. SKA excelled in recall performance, achieving 0.724 (1.0% improvement), valuable for comprehensive building crack detection. All variants maintained practical deployment feasibility, supporting real-time building inspection applications. The findings confirm that attention mechanism integration offers an effective approach to enhance YOLOv8 for building crack detection, providing empirical evidence for attention module selection based on specific deployment constraints and supporting the development of more reliable automated building inspection systems.

9 March 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
Tobit U IgbaTobit U Igba
Tobit U Igba
OOOluwole Olatunji
Oluwole Olatunji
Sikiru IsmailSikiru Ismail
Sikiru Ismail
SOSolomon Oyebisi
Solomon Oyebisi
OAOladapo Abiola
Oladapo Abiola
POPeter Olugbenga Omotainse
Peter Olugbenga Omotainse
Lagoon environments exposed concrete structures to sulphate and chloride-rich conditions that sped up deterioration and put traditional service-life prediction techniques to the test. The degrading behaviour of C30 concrete with crystalline and hydrophobic admixtures was measured in this study under controlled exposure to saline lagoon water, which are typical of coastal developed settings. To enhance long-term durability forecasting, a dual-phase degradation modelling framework was created that combined environmental deterioration kinetics with mechanical performance indicators. Both Power Law and Logarithmic growth models were used to evaluate phase I maturity; they showed consistent hydration in freshwater but a sharp decline in correlation when exposed to lagoon water After a 90-day kinetic tipping point, where traditional growth-based models overestimated residual capacity by up to 120%, Phase II used an exponential decay formulation to describe actual long-term deterioration trends. According to results from a 220-day exposure study, split tensile strength offered more sensitivity to interfacial transition zone (ITZ) deterioration, while compressive strength concealed early-stage microstructural damage. Over the anticipated service life, the crystalline-modified mix (C+AQ) maintained a higher Relative Durability Index (RDI) and decreased the degradation rate constant by 87.2% in comparison to the control. Densification of the ITZ and decreased ionic intrusion in the improved system were confirmed by microstructural investigation. These results showed that tensile-centric, dual-phase modelling, which included both exponential decay-based long-term prediction and Power Law hydration assessment, offered a strong framework for evaluating durability and designing ecologically friendly coastal concrete infrastructure.