Tazwar Bakhtiyar Zahid

Tazwar Bakhtiyar Zahid

Auto-generated profile, based on publicly available information

Tazwar Bakhtiyar Zahid

Department of Civil Engineering BUET Dhaka Bangladesh

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2022 in Structural Concrete
Verified
Journal Article
Closed access
TZTazwar Bakhtiyar Zahid
Tazwar Bakhtiyar Zahid
KAKhan Mahmud Amanat
Khan Mahmud Amanat

1 January 2025 in Structural Control and Health Monitoring
Verified
Journal Article
Open access
TZTazwar Bakhtiyar Zahid
Tazwar Bakhtiyar Zahid
SRShohel Rana
Shohel Rana
NHNiamul Haque
Niamul Haque
The application of machine learning techniques in bridge health monitoring is gaining widespread popularity as it overcomes the problems faced by conventional methods. However, the scarcity of labeled data for damaged bridges in training the model acts as a hindrance. The present study proposes a data science–based novel approach for overcoming this hindrance using a semisupervised, output‐only method for multiple‐level damage identification of a steel truss bridge. The method employs sequence‐to‐sequence modeling of vehicle‐induced vibration response only from a single sensor position. The authors have used a bidirectional long short‐term memory (BiLSTM) network for damage feature extraction. A statistical distance metric tool, Kullback–Leibler divergence, has then been utilized for feature discrimination. The method’s efficiency is numerically investigated through a 3‐D finite element model of a steel truss bridge based on real bridge specifications. A dynamic analysis using a moving vehicle is performed to obtain vehicle‐induced accelerations. A total of 36 different damage scenarios have then been incorporated into the bridge. The effect of sensor position and performance because of variation in vehicle operation has also been investigated. The results show that the proposed approach successfully detects all the damage scenarios. The methodology’s performance has also been validated in detecting damages for the Old ADA Bridge benchmark data. The methodology successfully detected multiple damage states using a single sensor response.

1 January 2025 in Advances in Civil Engineering
Verified
Journal Article
Open access
TZTazwar Bakhtiyar Zahid
Tazwar Bakhtiyar Zahid
KAKhan Mahmud Amanat
Khan Mahmud Amanat
Solid reinforced concrete (RC) floor systems have become susceptible to vibration from walking‐induced excitation due to the lightweight characteristics of concrete. This reduces the serviceability of the building in terms of occupant discomfort, adaptability to dynamic load, durability issues resulting from undesirable cracking, and service life. The present study evaluates the vibrational response of square solid RC slab panels supported on column line beams for synchronized multiperson walking. The study adopts a finite element (FE) methodology using linear modal time history analyses. The FE analyses model used for the study has been developed to replicate the response of a commercial space on an intermediate floor of a multistory building when subjected to synchronized multiperson walking excitation. The adopted methodology has been validated against past experimental results. A justification has also been established behind the walking and data acquisition parameters used for this study. A parametric study has been conducted to evaluate the response of the slab system for varying span lengths, slab thickness, and number of people. Peak acceleration responses obtained were then compared against different design guide limits for minimum slab thickness and allowable peak acceleration levels. The comparison revealed that existing design guide limits for minimum slab thickness might be insufficient to circumvent walking‐induced vibration discomfort. Based on the observations, revised minimum slab thickness was also proposed for different span lengths, which varied from 175 mm at 5 m to 225 mm at 9 m span for commercial spaces and 225 mm at 5 m to 350 mm at 9 m span for residential buildings. These findings will assist engineers in deciding the minimum slab thickness based on the span length, circumventing walking‐induced vibration discomfort.

11 July 2025 in Innovative Infrastructure Solutions
Verified
Journal Article
Closed access
PDF file
ASAhmed Farhan Ahnaf Siddique
Ahmed Farhan Ahnaf Siddique
RARaquib Ahsan
Raquib Ahsan
TZTazwar Bakhtiyar Zahid
Tazwar Bakhtiyar Zahid

23 January 2026 in Structural Concrete
Verified
Journal Article
Closed access
TZTazwar Bakhtiyar Zahid
Tazwar Bakhtiyar Zahid
KAKhan Mahmud Amanat
Khan Mahmud Amanat