14 August 2017 in IOP Conference Series: Materials Science and Engineering
MRMohd Nasrull Abdol Rahman
Mohd Nasrull Abdol Rahman
10 April 2013 in Applied Mechanics and Materials
For many years, researcher have focused on developing a medical part of human body from polymer as to replace metal. This report described the mechanical characteristic of biodegradable Polycaprolactone (PCL) blend with nanoMontmorillonite (MMT) and Hydroxyapatite (HA). The amount of nanoMMT is varies from 2 to 4 by weight % meanwhile the amount of HA is fixed to 10 by weight percentage (wt %). The addition of nanoMMT and HA filler is to tune and indirectly improve the mechanical properties of PCL. These are proven by carrying out the tensile, and also flexural test for samples which is injected from injection molding machine. Both the tensile and flexural test are conducted using Shimadzu AG-I Unversal Testing Machine with 10kN capacity. From the analysis it is found that overall PCL/MMT/HA composites gives better result in both tensile and flexural analysis compare to PCL/MMT composite. PCL/MMT/HA composite with 2 wt% of MMT and 10 wt% of HA have indicated the highest tensile modulus, meanwhile PCL/MMT/HA composite with 4 wt% MMT and 10 wt% HA have plotted the highest flexural strength and modulus value.
1 August 2019 in IOP Conference Series: Materials Science and Engineering
OMOmar Mohd Faizan Marwah
MRMohd Nasrull Abdol Rahman
Mohd Nasrull Abdol Rahman
Fabrication of medical implant using composite Polycaprolactone (PCL) / Polylactic Acid (PLA) through a process of fused filament fabrication (FFF) is the future of medical field. In this study the capabilities of FFF process and optimization of the Parameter was investigated to achieve the 20mm × 20mm × 10mm dimensional accuracy of printed composite material. Design of experiment using technique full factorial with two level design is used to study the interaction of factor which is print temperature (A), height of deposition (B), print speed (C) and travel speed (D). By using DOE, the total 20 run include with 4 center point was investigated by extruding the composite material using 3D printer. The dimension accuracy is tested using flexible measuring machine. From the sample, the ANOVA analysis of variance is divided into 3 responses, length, width and height. Factor model A, C and BD show the significant effect on length and for width response, factor model effected the dimensional accuracy is A, C, AC, and AD. Meanwhile for height respond only factor model A and C show the significant effect on the respond. Based on the analysis, one optimum parameter run is selected among ten of the suggested run. The optimum parameter value consists of 136°C print temperature, 0.12mm deposition of height, 20mm/s printing speed and 22mm/s travel speed. The confirmation run analysis this optimum parameter shows the precise dimension with average margin error below that 15% for length, width and height respond.
1 January 2020 in Materials Today: Proceedings
30 October 2017 in Journal of Physics: Conference Series
In this study, Polycaprolactone / Polylactice Acid (PCL/PLA) composite are used to fabricate filament wire with the specific diameter, which is in the range of 1.75 to 1.80 mm. Full factorial experimental design technique was used to study the main effects and the interaction effects between operational parameter which is (A) die temperature, (B) roller puller speed, (C) spindle speed and (D) inlet temperature. Besides that, there are two levels (-1 and +1) and the response are filament wire diameter. There are 16 numbers of runs and plus 8 centre points per blocks which makes the runs into 24 runs. From the experiment it shows that there are four factor that are significant effects on the filament wire diameter which is A, B, C and BC. The optimum parameter setting are also determined and there are 10 suggestions to achieve the target with different setting of parameter. The margin error for confirmation run is below than 15% when the parameter set at 6 Hz spindle speed, 4.99 rpm roller puller, 100.31 °C die temperature and 79.65 °C inlet temperature which can be noted that the confirmation run result is acceptable. The optimization parameter setting can use to continue in Fused Deposition Modelling (FDM). Filament wire from PCL/PLA are succesfully fabricated with acceptable diameter size and ready to be used for Fused Depotion Modelling process (FDM).
1 October 2018 in International Journal of Integrated Engineering
AAAhmad Mubarak Tajul Arifin
Ahmad Mubarak Tajul Arifin
MRMohd Nasrull Abdol Rahman
Mohd Nasrull Abdol Rahman
+2
Surface Roughness and Surface Topography of Inconel 718 in Powder Mixed Dielectric Electrical Discharge Machining (PMEDM)