9 March 2020 in IEEE Transactions on Smart Grid
The energy management system becomes increasingly indispensable with the extensive penetration of new players in the distribution networks, such as renewable energy, storage, and controllable load. Also, the operation optimization of the active distribution system requires information on operation state monitoring. Smart measuring equipment enables the topology identification and branch line parameters estimation from a data-driven perspective. Nevertheless, many current methods require the nodal voltage angles measured by phasor measurement units (PMUs), which might be unrealistic for conventional distribution networks. This paper proposes a numerical method to identify the topology and estimate line parameters without the information of voltage angles. We propose a two-step framework: the first step applies a data-driven regression method to provide a preliminary estimation on the topology and line parameter; the second step utilizes a joint data-and-model-driven method, i.e., a specialized Newton-Raphson iteration and power flow equations, to calculate the line parameter, recover voltage angle and further correct the topology. We test the method on IEEE 33 and 123-bus looped networks with load data from 1000 users in Ireland. The results demonstrate that the proposed method can provide an accurate estimation of the topology and line parameters based on limited samples of measurement without voltage angles.
7 November 2022 in IEEE Transactions on Power Systems
Increasing renewable energy penetrations bring complex feasibility and stability problems. Data-driven methods are applied in extracting and embedding these feasibility and stability rules in power system operations and planning. This paper presents a method of alternate support vector machine decision trees for rule extraction problems. The method significantly improves the classical decision-tree-based algorithms' efficiency, stability, and versatility. Finally, we apply the method to several power and energy system scenarios to show its effectiveness.
17 June 2021 in IEEE Transactions on Power Systems
Topology identification and parameter estimation form the basis for the operation and control of the distribution network with little or no observability. This paper proposes a method to estimate the admittance matrix for open-loop distribution networks based only on active/reactive power injection and voltage magnitude data. We derive the linear relationship between the admittance matrix and the measurements based on decoupled linear power flow (DLPF) equations. A total least squares regression method is proposed based on analysis of the characteristics of the open-loop grid admittance matrix. Case studies on the IEEE 33-bus system demonstrate the proposed method's effectiveness, accuracy, and efficiency.
17 October 2022 in IEEE Transactions on Power Systems
Renewable energy resources, such as wind and solar energy, have become the primary components of power systems. However, the uncertainty and fluctuations associated with these resources increase the difficulty to follow renewable fluctuations using conventional generators. Energy storage systems are one of the best choices for improving the mechanical performance limitations of conventional units. In this paper, we analyze the dynamic performance of the conventional-storage frequency regulation model and provide parameter and capacity setting rules for storage. Furthermore, we allocate the storage capacity to buses under different operation modes to minimize transmission-line fluctuations. We use a possible planning power systems in Jiangsu Province, China, in 2030 to analyze and verify our proposal. The system has more than 1000 buses, 2000 branches and 700 generators, and 220, 500 and 1000 kV voltage levels. The results show that using a small amount of storage is feasible for improving regulation performances. Additionally, the optimal energy storage placement effectively reduces the fluctuations and optimizes the power flows in the transmission systems.
27 December 2023 in Applied Energy
19 March 2020 in IEEE Transactions on Engineering Management
The integration of distributed renewable energy and the implementation of the demand response complicate the change patterns of load profiles and present great uncertainties. Probabilistic load forecasting, an effective method for capturing the future load uncertainty, has been a hot issue. This article proposes a two-stage bootstrap sampling method for probabilistic load forecasting. In the first stage, alpha-bootstrap, which is a modification of traditional bootstrap methods, is applied to characterize the uncertainties from multiple forecasting models; in the second stage, the residual bootstrap method is used to formulate the regression errors. Finally, the probabilistic load forecasts can be obtained by integrating the uncertainties in both stages. Various off-the-shelf point load forecasting methods such as random forest (RF) and gradient boosting regression tree (GBRT) can be integrated into the proposed framework. We illustrate the effectiveness of our proposed method and superiority over direct quantile regression methods such as quantile RF and quantile GBRT using the case studies on open load datasets of eight zones in ISO New-England.