Marc Schwaerzel

Marc Schwaerzel

Auto-generated profile, based on publicly available information

Marc Schwaerzel

Swiss Federal Laboratories for Materials Science and Technology (EMPA), Dübendorf, Switzerland

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2020 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
MSMarc Schwaerzel
Marc Schwaerzel
CEClaudia Emde
Claudia Emde
DBDominik Brunner
Dominik Brunner
RMRandulph Morales
Randulph Morales
TWThomas Wagner
Thomas Wagner
GKGerrit Kuhlmann
Gerrit Kuhlmann
Air mass factors (AMFs) are used in passive trace gas remote sensing for converting slant column densities (SCDs) to vertical column densities (VCDs). AMFs are traditionally computed with 1D radiative transfer models assuming horizontally homogeneous conditions. However, when observations are made with high spatial resolution in a heterogeneous atmosphere or above a heterogeneous surface, 3D effects may not be negligible. To study the importance of 3D effects on AMFs for different types of trace gas remote sensing, we implemented 1D-layer and 3D-box AMFs into the Monte carlo code for the phYSically correct Tracing of photons In Cloudy atmospheres (MYSTIC), a solver of the libRadtran radiative transfer model (RTM). The 3D-box AMF implementation is fully consistent with 1D-layer AMFs under horizontally homogeneous conditions and agrees very well (<5 % relative error) with 1D-layer AMFs computed by other RTMs for a wide range of scenarios. The 3D-box AMFs make it possible to visualize the 3D spatial distribution of the sensitivity of a trace gas observation, which we demonstrate with two examples. First, we computed 3D-box AMFs for ground-based multi-axis spectrometer (MAX-DOAS) observations for different viewing geometry and aerosol scenarios. The results illustrate how the sensitivity reduces with distance from the instrument and that a non-negligible part of the signal originates from outside the line of sight. Such information is invaluable for interpreting MAX-DOAS observations in heterogeneous environments such as urban areas. Second, 3D-box AMFs were used to generate synthetic nitrogen dioxide (NO2) SCDs for an airborne imaging spectrometer observing the NO2 plume emitted from a tall stack. The plume was imaged under different solar zenith angles and solar azimuth angles. To demonstrate the limitations of classical 1D-layer AMFs, VCDs were then computed assuming horizontal homogeneity. As a result, the imaged NO2 plume was shifted in space, which led to a strong underestimation of the total VCDs in the plume maximum and an underestimation of the integrated line densities that can be used for estimating emissions from NO2 images. The two examples demonstrate the importance of 3D effects for several types of ground-based and airborne remote sensing when the atmosphere cannot be assumed to be horizontally homogeneous, which is typically the case in the vicinity of emission sources or in cities.

8 October 2021 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
MSMarc Schwaerzel
Marc Schwaerzel
DBDominik Brunner
Dominik Brunner
FJFabian Jakub
Fabian Jakub
CEClaudia Emde
Claudia Emde
BBBrigitte Buchmann
Brigitte Buchmann
GKGerrit Kuhlmann
Gerrit Kuhlmann
Airborne imaging remote sensing is increasingly used to map the spatial distribution of nitrogen dioxide (NO2) in cities. Despite the small ground-pixel size of the sensors, the measured NO2 distributions are much smoother than one would expect from high-resolution model simulations of NO2 over cities. This could partly be caused by 3D radiative transfer effects due to observation geometry, adjacency effects and effects of buildings. Here, we present a case study of imaging a synthetic NO2 distribution for a district of Zurich using the 3D MYSTIC (Monte carlo code for the phYSically correct Tracing of photons In Cloudy atmospheres) solver of the libRadtran radiative transfer library. We computed NO2 slant column densities (SCDs) using the recently implemented 3D-box air mass factors (3D-box AMFs) and a new urban canopy module to account for the effects of buildings. We found that for a single ground pixel (50 m × 50 m) more than 50 % of the sensitivity is located outside of the pixel, primarily in the direction of the main optical path between sun, ground pixel, and instrument. Consequently, NO2 SCDs are spatially smoothed, which results in an increase over roads when they are parallel to the optical path and a decrease otherwise. When buildings are included, NO2 SCDs are reduced on average by 5 % due to the reduced sensitivity to NO2 in the shadows of the buildings. The effects of buildings also introduce a complex pattern of variability in SCDs that would show up in airborne observations as an additional noise component (about 12 µmol m−2) similar to the magnitude of typical measurement uncertainties. The smearing of the SCDs cannot be corrected using 1D-layer AMFs that assume horizontal homogeneity and thus remains in the final NO2 map. The 3D radiative transfer effects by including buildings need to be considered to compute more accurate AMFs and to reduce biases in NO2 vertical columns obtained from high-resolution city-scale NO2 remote sensing.

21 March 2022 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
GKGerrit Kuhlmann
Gerrit Kuhlmann
KCKa Lok Chan
Ka Lok Chan
SDSebastian Donner
Sebastian Donner
YZYing Zhu
Ying Zhu
MSMarc Schwaerzel
Marc Schwaerzel
MWMark Wenig
Mark Wenig
We present results from the Munich Nitrogen dioxide (NO2) Imaging Campaign (MuNIC), where NO2 near-surface concentrations (NSCs) and vertical column densities (VCDs) were measured with stationary, mobile, and airborne in situ and remote sensing instruments in Munich, Germany. The most intensive day of the campaign was 7 July 2016, when the NO2 VCD field was mapped with the Airborne Prism Experiment (APEX) imaging spectrometer. The spatial distribution of APEX VCDs was rather smooth, with a horizontal gradient between lower values upwind and higher values downwind of the city center. The NO2 map had no pronounced source signatures except for the plumes of two combined heat and power (CHP) plants. The APEX VCDs have a fair correlation with mobile multi-axis differential optical absorption spectroscopy (MAX-DOAS) observations from two vehicles conducted on the same afternoon (r=0.55). In contrast to the VCDs, mobile NSC measurements revealed high spatial and temporal variability along the roads, with the highest values in congested areas and tunnels. The NOx emissions of the two CHP plants were estimated from the APEX observations using a mass-balance approach. The NOx emission estimates are consistent with CO2 emissions determined from two ground-based Fourier transform infrared (FTIR) instruments operated near one CHP plant. The estimates are higher than the reported emissions but are probably overestimated because the uncertainties are large, as conditions were unstable and convective with low and highly variable wind speeds. Under such conditions, the application of mass-balance approaches is problematic because they assume steady-state conditions. We conclude that airborne imaging spectrometers are well suited for mapping the spatial distribution of NO2 VCDs over large areas. The emission plumes of point sources can be detected in the APEX observations, but accurate flow fields are essential for estimating emissions with sufficient accuracy. The application of airborne imaging spectrometers for studying NSCs is less straightforward and requires us to account for the non-trivial relationship between VCDs and NSCs.

2 July 2021
Verified
Other
Open access
MSMarc Schwaerzel
Marc Schwaerzel
DBDominik Brunner
Dominik Brunner
FJFabian Jakub
Fabian Jakub
CEClaudia Emde
Claudia Emde
BBBrigitte Buchmann
Brigitte Buchmann
GKGerrit Kuhlmann
Gerrit Kuhlmann

27 October 2021 in EGUsphere
Verified
Preprint
Open access
PDF file
GKGerrit Kuhlmann
Gerrit Kuhlmann
KCKa Lok Chan
Ka Lok Chan
SDSebastian Donner
Sebastian Donner
YZYing Zhu
Ying Zhu
MSMarc Schwaerzel
Marc Schwaerzel
MWMark Wenig
Mark Wenig
We present results from the Munich NO2 imaging campaign (MuNIC) where nitrogen dioxide (NO2) near-surface concentrations (NSC) and vertical column densities (VCD) were measured with stationary, mobile and airborne in situ and remote sensing instruments. The most intensive day of the campaign was 7 July 2016, when the NO2 VCD field was mapped with the Airborne Prism Experiment (APEX) imaging spectrometer. The spatial distribution of APEX VCDs was rather smooth with a horizontal gradient between lower values upwind and higher values downwind of the city center. The NO2 map had no pronounced source signatures except for the plumes of two combined heat and power plants (CHP). The APEX VCDs agree well with mobile MAX-DOAS observations from two vehicles conducted in the same afternoon (r = 0.55). In contrast to the VCDs, mobile NSC measurements revealed high spatial and temporal variability along the roads with highest values in congested areas and tunnels. The NOx emissions of the two CHP plants were estimated from the APEX observations using a mass-balance approach. The estimates are higher than reported emissions, but uncertainties are high because the campaign day was unstable and convective, resulting in low and highly variable wind speeds. The NOx emission estimates are consistent with CO2 emissions determined from two ground-based FTIR instruments operated near one CHP plant. We conclude that airborne imaging spectrometers are well suited to map the spatial distribution of NO2 VCDs over large areas. The emission plumes of point sources can be detected in the APEX observations, but accurate flow fields are essential to estimate emissions with sufficient accuracy. The application of airborne imaging spectrometers for studying NSCs, for example as input for epidemiological studies, is less straight forward and requires to account for the non-trivial relationship between VCDs and NSCs.

2 July 2021 in EGUsphere
Verified
Preprint
Open access
PDF file
MSMarc Schwaerzel
Marc Schwaerzel
DBDominik Brunner
Dominik Brunner
FJFabian Jakub
Fabian Jakub
CEClaudia Emde
Claudia Emde
BBBrigitte Buchmann
Brigitte Buchmann
GKGerrit Kuhlmann
Gerrit Kuhlmann
Airborne imaging remote sensing is increasingly used to map the spatial distribution of nitrogen dioxide (NO2) in cities. Despite the small ground-pixel size of the sensors, the measured NO2 distributions are much smoother than one would expect from high-resolution model simulations of NO2 over cities. This could be caused by 3D radiative transfer effects due to observation geometry, adjacency effects and effects of buildings. Here, we present a case study of imaging a synthetic NO2 distribution for a district of Zurich using the 3D MYSTIC solver of the libRadtran radiative transfer library. We compute NO2 slant column densities (SCD) using the recently implemented 3D-box air mass factors (3D-box AMF) and a new urban canopy module to account for the effects of buildings. We found that for a single ground pixel (50 m × 50 m) more than 50 % of the sensitivity is located outside of the pixel, primarily in the direction of the main optical path between sun, ground pixel, and instrument. Consequently, NO2 SCDs are spatially smoothed, which results in an increase over roads when they are parallel to the optical path and a decrease otherwise. When buildings are included, NO2 SCDs are reduced on average by 5 % due to the reduced sensitivity to NO2 in the shadows of the buildings. The effects of buildings also introduce a complex pattern of variability in SCDs that would show up in airborne observations as an additional noise component (about 12 μmol m−2) similar to typical measurement uncertainties. The smearing of the SCDs cannot be corrected using 1D-layer AMFs that assume horizontal homogeneity and thus remains in the final NO2 map. 3D radiative transfer effects by including buildings need to be considered to compute more accurate AMFs and to reduce biases in NO2 vertical columns obtained from high-resolution city-scale NO2 remote sensing.