Josep-Anton Morguí

Josep-Anton Morguí

Auto-generated profile, based on publicly available information

Josep-Anton Morguí

Department of Evolutionary Biology, Ecology and Environmental Sciences, Universitat de Barcelona, Barcelona, 08028, Spain

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 June 2019 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
AAAnna Agustí-Panareda
Anna Agustí-Panareda
MDMichail Diamantakis
Michail Diamantakis
SMSébastien Massart
Sébastien Massart
FCFrédéric Chevallier
Frédéric Chevallier
JMJoaquín Muñoz-Sabater
Joaquín Muñoz-Sabater
DWDebra Wunch
Debra Wunch
Climate change mitigation efforts require information on the current greenhouse gas atmospheric concentrations and their sources and sinks. Carbon dioxide (CO2) is the most abundant anthropogenic greenhouse gas. Its variability in the atmosphere is modulated by the synergy between weather and CO2 surface fluxes, often referred to as CO2 weather. It is interpreted with the help of global or regional numerical transport models, with horizontal resolutions ranging from a few hundreds of kilometres to a few kilometres. Changes in the model horizontal resolution affect not only atmospheric transport but also the representation of topography and surface CO2 fluxes. This paper assesses the impact of horizontal resolution on the simulated atmospheric CO2 variability with a numerical weather prediction model. The simulations are performed using the Copernicus Atmosphere Monitoring Service (CAMS) CO2 forecasting system at different resolutions from 9 to 80 km and are evaluated using in situ atmospheric surface measurements and atmospheric column-mean observations of CO2, as well as radiosonde and SYNOP observations of the winds. The results indicate that both diurnal and day-to-day variability of atmospheric CO2 are generally better represented at high resolution, as shown by a reduction in the errors in simulated wind and CO2. Mountain stations display the largest improvements at high resolution as they directly benefit from the more realistic orography. In addition, the CO2 spatial gradients are generally improved with increasing resolution for both stations near the surface and those observing the total column, as the overall inter-station error is also reduced in magnitude. However, close to emission hotspots, the high resolution can also lead to a deterioration of the simulation skill, highlighting uncertainties in the high-resolution fluxes that are more diffuse at lower resolutions. We conclude that increasing horizontal resolution matters for modelling CO2 weather because it has the potential to bring together improvements in the surface representation of both winds and CO2 fluxes, as well as an expected reduction in numerical errors of transport. Modelling applications like atmospheric inversion systems to estimate surface fluxes will only be able to benefit fully from upgrades in horizontal resolution if the topography, winds and prior flux distribution are also upgraded accordingly. It is clear from the results that an additional increase in resolution might reduce errors even further. However, the horizontal resolution sensitivity tests indicate that the change in the CO2 and wind modelling error with resolution is not linear, making it difficult to quantify the improvement beyond the tested resolutions. Finally, we show that the high-resolution simulations are useful for the assessment of the small-scale variability of CO2 which cannot be represented in coarser-resolution models. These representativeness errors need to be considered when assimilating in situ data and high-resolution satellite data such as Greenhouse gases Observing Satellite (GOSAT), Orbiting Carbon Observatory-2 (OCO-2), the Chinese Carbon Dioxide Observation Satellite Mission (TanSat) and future missions such as the Geostationary Carbon Observatory (GeoCarb) and the Sentinel satellite constellation for CO2. For these reasons, the high-resolution CO2 simulations provided by the CAMS in real time can be useful to estimate such small-scale variability in real time, as well as providing boundary conditions for regional modelling studies and supporting field experiments.

10 January 2022 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
QTQiansi Tu
Qiansi Tu
FHFrank Hase
Frank Hase
MSMatthias Schneider
Matthias Schneider
OGOmaira García
Omaira García
TBThomas Blumenstock
Thomas Blumenstock
CTCarlos Torres
Carlos Torres
The objective of this study is to derive methane (CH4) emissions from three landfills, which are found to be the most significant CH4 sources in the metropolitan area of Madrid in Spain. We derive CH4 emissions from the CH4 enhancements observed by spaceborne and ground-based instruments. We apply satellite-based measurements from the TROPOspheric Monitoring Instrument (TROPOMI) and the Infrared Atmospheric Sounding Interferometer (IASI) together with measurements from the ground-based COllaborative Carbon Column Observing Network (COCCON) instruments. In 2018, a 2-week field campaign for measuring the atmospheric concentrations of greenhouse gases was performed in Madrid in the framework of Monitoring of the Greenhouse Gases Concentrations in Madrid (MEGEI-MAD) project. Five COCCON instruments were deployed at different locations around the Madrid city center, enabling the observation of total column-averaged CH4 mixing ratios (XCH4). Considering the prevalent wind regimes, we calculate the wind-assigned XCH4 anomalies for two opposite wind directions. Pronounced bipolar plumes are found when applying the method to NO2, which implies that our method of wind-assigned anomaly is suitable to estimate enhancements of trace gases at the urban level from satellite-based measurements. For quantifying the CH4 emissions, the wind-assigned plume method is applied to the TROPOMI XCH4 and to the lower tropospheric CH4 / dry-air column ratio (TXCH4) of the combined TROPOMI+IASI product. As CH4 emission strength we estimate 7.4 × 1025 ± 6.4 × 1024 molec. s−1 from the TROPOMI XCH4 data and 7.1 × 1025 ± 1.0 × 1025 molec. s−1 from the TROPOMI+IASI merged TXCH4 data. We use COCCON observations to estimate the local source strength as an independent method. COCCON observations indicate a weaker CH4 emission strength of 3.7 × 1025 molec. s−1 from a local source (the Valdemingómez waste plant) based on observations from a single day. This strength is lower than the one derived from the satellite observations, and it is a plausible result. This is because the analysis of the satellite data refers to a larger area, covering further emission sources in the study region, whereas the signal observed by COCCON is generated by a nearby local source. All emission rates estimated from the different observations are significantly larger than the emission rates provided via the official Spanish Register of Emissions and Pollutant Sources.

26 April 2018 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
Claudia GrossiClaudia Grossi
Claudia Grossi
FVFelix Vogel
Felix Vogel
RCRoger Curcoll
Roger Curcoll
AAALBA AGUEDA
ALBA AGUEDA
AVArturo Vargas
Arturo Vargas
JMJosep-Anton Morguí
Josep-Anton Morguí
The ClimaDat station at Gredos (GIC3) has been continuously measuring atmospheric (dry air) mixing ratios of carbon dioxide (CO2) and methane (CH4), as well as meteorological parameters, since November 2012. In this study we investigate the atmospheric variability of CH4 mixing ratios between 2013 and 2015 at GIC3 with the help of co-located observations of 222Rn concentrations, modelled 222Rn fluxes and modelled planetary boundary layer heights (PBLHs). Both daily and seasonal changes in atmospheric CH4 can be better understood with the help of atmospheric concentrations of 222Rn (and the corresponding fluxes). On a daily timescale, the variation in the PBLH is the main driver for 222Rn and CH4 variability while, on monthly timescales, their atmospheric variability seems to depend on emission changes. To understand (changing) CH4 emissions, nocturnal fluxes of CH4 were estimated using two methods: the radon tracer method (RTM) and a method based on the EDGARv4.2 bottom-up emission inventory, both using FLEXPARTv9.0.2 footprints. The mean value of RTM-based methane fluxes (FR_CH4) is 0.11 mg CH4 m−2 h−1 with a standard deviation of 0.09 or 0.29 mg CH4 m−2 h−1 with a standard deviation of 0.23 mg CH4 m−2 h−1 when using a rescaled 222Rn map (FR_CH4_rescale). For our observational period, the mean value of methane fluxes based on the bottom-up inventory (FE_CH4) is 0.33 mg CH4 m−2 h−1 with a standard deviation of 0.08 mg CH4 m−2 h−1. Monthly CH4 fluxes based on RTM (both FR_CH4 and FR_CH4_rescale) show a seasonality which is not observed for monthly FE_CH4 fluxes. During January–May, RTM-based CH4 fluxes present mean values 25 % lower than during June–December. This seasonal increase in methane fluxes calculated by RTM for the GIC3 area appears to coincide with the arrival of transhumant livestock at GIC3 in the second half of the year.

8 May 2020 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
Claudia GrossiClaudia Grossi
Claudia Grossi
SCScott Chambers
Scott Chambers
OLOlivier Llido
Olivier Llido
FVFelix Vogel
Felix Vogel
VKVictor Kazan
Victor Kazan
MRMichel Ramonet
Michel Ramonet
The use of the noble gas radon (222Rn) as a tracer for different research studies, for example observation-based estimation of greenhouse gas (GHG) fluxes, has led to the need of high-quality 222Rn activity concentration observations with high spatial and temporal resolution. So far a robust metrology chain for these measurements is not yet available. A portable direct atmospheric radon monitor (ARMON), based on electrostatic collection of 218Po, is now running at Spanish stations. This monitor has not yet been compared with other 222Rn and 222Rn progeny monitors commonly used at atmospheric stations. A 3-month intercomparison campaign of atmospheric 222Rn and 222Rn progeny monitors based on different measurement techniques was realized during the fall and winter of 2016–2017 to evaluate (i) calibration and correction factors between monitors necessary to harmonize the atmospheric radon observations and (ii) the dependence of each monitor's response in relation to the sampling height and meteorological and atmospheric aerosol conditions. Results of this study have shown the following. (i) All monitors were able to reproduce the atmospheric radon variability on a daily basis. (ii) Linear regression fits between the monitors exhibited slopes, representing the correction factors, between 0.62 and 1.17 and offsets ranging between −0.85 and −0.23 Bq m−3 when sampling 2 m above ground level (a.g.l.). Corresponding results at 100 m a.g.l. exhibited slopes of 0.94 and 1.03 with offsets of −0.13 and 0.01 Bq m−3, respectively. (iii) No influence of atmospheric temperature and relative humidity on monitor responses was observed for unsaturated conditions at 100 m a.g.l., whereas slight influences (order of 10−2) of ambient temperature were observed at 2 m a.g.l. (iv) Changes in the ratio between 222Rn progeny and 222Rn monitor responses were observed under very low atmospheric aerosol concentrations. Results also show that the new ARMON could be useful at atmospheric radon monitoring stations with space restrictions or as a mobile reference instrument to calibrate in situ 222Rn progeny monitors and fixed radon monitors. In the near future a long-term comparison study between ARMON, HRM, and ANSTO monitors would be useful to better evaluate (i) the uncertainties of radon measurements in the range of a few hundred millibecquerels per cubic meter to a few becquerels per cubic meter and (ii) the response time correction of the ANSTO monitor for representing fast changes in the ambient radon concentrations.

1 April 2022 in Environmental Research
Verified
Journal Article
Open access
XQXavier Querol
Xavier Querol
Andrés Alastuey UrósAndrés Alastuey Urós
Andrés Alastuey Urós
NPNatalia Moreno Palmerola
Natalia Moreno Palmerola
MMMaria Cruz Minguillón
Maria Cruz Minguillón
TMTeresa Moreno
Teresa Moreno
JFJosé Manuel Felisi
José Manuel Felisi
Measurements of CO2 and counting of occupants were carried out in 37 public bus trips during commuting rush hours in Barcelona (NE Spain) with the aim of evaluating parameters governing ventilation inside the vehicles and proposing actions to improve it. The results show that CO2 concentrations (1039 and 934 ± 386 ppm, as average and median, during rush hours but with average reduced occupancy due to the fair to be infected by SARS-CoV-2 during the measurement period, and measured in the middle of the busses) are in the lower range of values recorded in the literature for public buses, however an improvement in ventilation is required in a significant proportion of the journeys. Thus, we found better ventilation in the older Euro 3+ (retrofitted with filter traps and selective catalytic reduction) and Euro 5 buses (average 918 ± 257 ppm) than in the hermetically closed new Euro 6 ones (1111 ± 432 ppm). The opening of the windows in the older buses yielded higher ventilation rates (778 ± 432 ppm). The opening of all doors at all stops increases the ventilation by causing a fall in concentrations of 200-350 ppm below inter-stop concentrations, with this effect typically lasting 40-50 s in the hermetically closed new Euro 6 hybrid buses. Based on these results a number of recommendations are offered in order to improve ventilation, including measurement of CO2 and occupancy, and installation of ventilation fans on the top of the hermetically closed new buses, introducing outdoor air when a given concentration threshold is exceeded. In these cases, a CO2 sensor installed in the outdoor air intake is also recommended to take into account external CO2 contributions.

9 May 2022 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
RCRoger Curcoll
Roger Curcoll
JMJosep-Anton Morguí
Josep-Anton Morguí
AKArmand Kamnang
Armand Kamnang
LCLídia Cañas
Lídia Cañas
AVArturo Vargas
Arturo Vargas
Claudia GrossiClaudia Grossi
Claudia Grossi
Soil CO2 emissions are one of the largest contributions to the global carbon cycle, and a full understanding of processes generating them and how climate change may modify them is needed and still uncertain. Thus, a dense spatial and temporal network of CO2 flux measurements from soil could help reduce uncertainty in the global carbon budgets. In the present study, the design, assembly, and calibration of low-cost air enquirer kits, including CO2 and environmental parameters sensors, is presented. Different types of calibrations for the CO2 sensors and their associated errors are calculated. In addition, for the first time, this type of sensor has been applied to design, develop, and test a new steady-state through-flow (SS-TF) chamber for simultaneous measurements of CO2 fluxes in soil and CO2 concentrations in air. The sensors' responses were corrected for temperature, relative humidity, and pressure conditions in order to reduce the uncertainty in the measured CO2 values and of the following calculated CO2 fluxes based on SS-TF. CO2 soil fluxes measured by the proposed SS-TF and by a standard closed non-steady-state non-through-flow (NSS-NTF) chamber were briefly compared to ensure the reliability of the results. The use of a multiparametric fitting reduced the total uncertainty of the CO2 concentration measurements by 62 %, compared with the uncertainty that occurred when a simple CO2 calibration was applied, and by 90 %, when compared to the uncertainty declared by the manufacturer. The new SS-TF system allows the continuous measurement of CO2 fluxes and CO2 ambient air with low cost (EUR ∼1200), low energy demand (<5 W), and low maintenance (twice per year due to sensor calibration requirements).