The production of biofilm is thought to be crucial in the pathogenesis of prosthetic-device infections caused byStaphylococcus epidermidis. An experimental animal model was used to assess the importance of biofilm production, which is mediated by polysaccharide intercellular adhesin/hemagglutinin (PIA/HA), in the pathogenesis of a biomaterial-based infection. Mice were inoculated along the length of a subcutaneously implanted intravenous catheter with either wild-typeS. epidermidis1457 or its isogenic PIA/HA-negative mutant. The wild-type strain was significantly more likely to cause a subcutaneous abscess than the mutant strain (P< 0.01) and was significantly less likely to be eradicated from the inoculation site by host defense (P< 0.05). In addition, the wild-type strain was found to adhere to the implanted catheters more abundantly than the PIA/HA-negative mutant (P< 0.05). The reliability of the adherence assay was assessed by scanning electron microscopy. To exclude contamination or spontaneous infection, bacterial strains recovered from the experimental animals were compared to inoculation strains by analysis of restriction fragment length polymorphism patterns by pulsed-field gel electrophoresis. In vitro binding of the wild-type strain and its isogenic mutant to a fibronectin-coated surface was similar. These results confirm the importance of biofilm production, mediated by PIA/HA, in the pathogenesis ofS. epidermidisexperimental foreign body infection.
1 December 2004 in American Journal of Infection Control
Central venous catheter-related infections are a significant medical problem. Improved preventive measures are needed. To ascertain 1) effectiveness of a second-generation antiseptic-coated catheter in the prevention of microbial colonization and infection; 2) safety and tolerability of this device; 3) microbiology of infected catheters; and 4) propensity for the development of antiseptic resistance. Multicenter, randomized, double-blind, controlled trial. 9 university-affiliated medical centers. 780 patients in intensive care units who required central venous catheterization. Patients received either a standard catheter or a catheter coated with chlorhexidine and silver sulfadiazine. The authors assessed catheter colonization and catheter-related infection, characterized microbes by molecular typing, and determined their susceptibility to antiseptics. Patient tolerance of the catheter was monitored. Patients with the 2 types of catheters had similar demographic features, clinical interventions, laboratory values, and risk factors for infection. Antiseptic catheters were less likely to be colonized at the time of removal compared with control catheters (13.3 vs. 24.1 colonized catheters per 1000 catheter-days; P < 0.01). The center-stratified Cox regression hazard ratio for colonization controlling for sampling design and potentially confounding variables was 0.45 (95% CI, 0.25 to 0.78). The rate of definitive catheter-related bloodstream infection was 1.24 per 1000 catheter-days (CI, 0.26 to 3.62 per 1000 catheter-days) for the control group versus 0.42 per 1000 catheter-days (CI, 0.01 to 2.34 per 1000 catheter-days) for the antiseptic catheter group (P = 0.6). Coagulase-negative staphylococci and other gram-positive organisms were the most frequent microbes to colonize catheters. Noninfectious adverse events were similar in both groups. Antiseptic susceptibility was similar for microbes recovered from either group. The antiseptic catheter was not compared with an antibiotic-coated catheter, and no conclusion can be made regarding its effect on bloodstream infection. The second-generation chlorhexidine-silver sulfadiazine catheter is well tolerated. Antiseptic coating appears to reduce microbial colonization of the catheter compared with an uncoated catheter.
1 April 2001 in The Journal of Infectious Diseases