22 October 2007 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Equivalent circuits for piezoelectric devices and ultrasonic transmission media can be used to cosimulate electronics and ultrasound parts in simulators originally intended for electronics. To achieve efficient system- level optimization, it is important to simulate correct, absolute amplitude of the ultrasound signal in the system, as this determines the requirements on the electronics regarding dynamic range, circuit noise, and power consumption. This paper presents methods to achieve correct, absolute amplitude of an ultrasound signal in a simulation of a pulse-echo system using equivalent circuits. This is achieved by taking into consideration loss due to diffraction and the effect of the cable that connects the electronics and the piezoelectric transducer. The conductive loss in the transmission line that models the propagation media of the ultrasound pulse is used to model the loss due to diffraction. Results show that the simulated amplitude of the echo follows measured values well in both near and far fields, with an offset of about 10%. The use of a coaxial cable introduces inductance and capacitance that affect the amplitude of a received echo. Amplitude variations of 60% were observed when the cable length was varied between 0.07 m and 2.3 m, with simulations predicting similar variations. The high precision in the achieved results show that electronic design and system optimization can rely on system simulations alone. This will simplify the development of integrated electronics aimed at ultrasound systems.
28 June 2017 in Analog Integrated Circuits and Signal Processing
This paper analyses leakage current compensation techniques for low-power, bandgap temperature sensors. Experiments are conducted for circuits that compensate for collector-substrate, collector-base, body-drain and source-body leakage currents in a Brokaw bandgap sensor. The sensors are characterised and their failure modes are analysed at temperatures from 60 to \(230^{\,\circ }\hbox {C}\). It is found that the most appropriate compensation circuit depends on the accuracy requirements of the application and on whether a stable reference voltage is required by other parts of the circuit. Experiments show that the power consumption is dominated by leakage current at high temperatures. One type of sensor was seen to consume 260 nW at \(60 ^{\,\circ }\hbox {C}\), \(2.1\, \upmu \hbox {W}\) at \(200^{\,\circ }\hbox {C}\) and \(14\, \upmu \hbox {W}\) at \(230^{\,\circ }\hbox {C}\). This work is motivated by the need to accurately monitor the temperature of power semiconductors in order to predict emerging faults in power semiconductor modules, a task for which cheap, single-chip, low-power, high-temperature, wireless bandgap temperature sensors are appropriate.
3 April 2015 in Analog Integrated Circuits and Signal Processing