17 March 2023 in İnönü Üniversitesi Sağlık Hizmetleri Meslek Yüksek Okulu Dergisi
In this study, the spectral and optical properties of organic spectacle lenses used as visual aids were analyzed using Jasco V-730 UV/VIS spectrophotometer device in the ultraviolet and visible light wavelength ranges. The results obtained showed that the light transmittance in the wavelength (550nm) range to which the human eye is most sensitive in the lens samples examined was over 80% and that Polycarbonate (A3) lenses had a maximum value of 97.87%. The largest cut-off edge wavelength value was found to be 390nm for the A3 lens. At 550 nm for all lenses, the absorption spectrum was below 0.07. In terms of visual quality, it is expected that the visible light transmittance is high and the ultraviolet light transmission is minimal. Our eyes are exposed to ultraviolet rays almost every day, and these rays cause damage to the ocular tissues. The degree of damage caused by the amount of ultraviolet light absorption increases. Among the organic lenses with ultraviolet protection coating, the protection of the A3 lens was relatively higher. Furthermore, optical band gap energies were found to range from 3.145 – 4.155 eV and 2.994 – 3.936 eV for direct and indirect transitions, respectively. The highest optical band gap values were found to be those of the B1 and C1 organic lenses, respectively.
20 March 2022 in Turkish Journal of Science and Technology
In the present study, Energy Absorption Buildup Factor (EABF) and Exposure Buildup Factors (EBF) of the CR-39 and Trivex optical lenses are calculated by using the Geometric Progression (GP) fitting method based on ANSI/ANS-6.4.3 database. The study analyses comprehensively for different penetration depths within the energy range of 0.015 - 15 MeV up to 40 mfp. The buildup factors are calculated in the examined materials depending on the photon energy that arrives, the penetration depths, and the chemical composition of the material reach at maximum values in the energy region where inconsistent scattering interaction probabilities are intensive. The results show that the CR-39 optical lens had better radiation shielding performance. The suitability of the results is compared with the powerful software tools (EPICS2017 and Phy-X/PSD), which are preferred frequently in the literature to calculate radiation shielding parameters. It is found that the relative changes between the EPICS2017 and Phy-X/PSD software compared with the results of this study are about 8% and 9% for the CR-39 and Trivex optical lens, respectively. This indicates that the results from the study are in good agreement.
19 August 2019 in Journal of Radioanalytical and Nuclear Chemistry
11 March 2019 in Environmental Earth Sciences
18 December 2023 in Journal of Physical Chemistry and Functional Materials
The optical properties of the prescription and non-prescription (plano) samples of the MR-8 high index lens were examined by UV/VIS spectrometry. The results showed that the light transmittance of the two MR-8 lens samples examined was over 90%, and the transmittance at the wavelength (~550nm) to which the human eye is most sensitive was 83.437% and 84.602% for the prescription and non-prescription samples, respectively. In terms of quality of vision, it is expected that the visible light transmittance will be high and the ultraviolet light transmittance will be minimal. It is very important that both the prescription and non-prescription organic MR-8 lenses tested have no transmittance below approximately 398nm. This means that this lens material protects against UVA and UVB rays, even though it is uncoated. It is also important to reduce the dose to the lens, which is a radiosensitive tissue. In the study, the mass absorption coefficients of MR-8 and Ormix lens materials in the 0.15-2.00 MeV energy range were calculated using the web-based XCOM programme. LAC, HVL, TVL, MFP, RPE and TF values were calculated from the MAC values obtained. At energies below 0.05 MeV, the maximum MAC value was 0.974 and 4.416 for the MR-8 and Ormix lenses, respectively. The RPE and TF values were 0.807-16.235%, 0.996-0.992% for the MR-8 lens and 0.862-55.233%, 0.448-0.991% for the Ormix lens. The results showed that the photon absorption ability of the Ormix lens is relatively better in the region where the photoelectric interaction is dominant. This research is also important in terms of determining the optical and nuclear radiation parameters of the material used in the manufacture of high index lenses and investigating its effectiveness in reducing the dose to the eyepiece.