Mart Min

Mart Min

Auto-generated profile, based on publicly available information

Mart Min

Tallinn University of Technology

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2007 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MMMart Min
Mart Min
TPToomas Parve
Toomas Parve
A novel solution for improving lock-in electrical bio-impedance (EBI) analyzers by suppressing errors caused by higher odd harmonics of rectangular wave pulses is proposed. The solution is based on a newly developed method of shortening the rectangular full duty cycle pulses, which are commonly used in correlation-type lock-in EBI measurements. Comparison of the proposed method to a common method of regular rectangular waveforms is given. The results show that the measurement errors of the three-element EBI equivalent become several tens of times smaller when shortening the excitation and reference signals separately by different values, for example, by 30 deg and 18deg. Shortening of only a single signal (either excitation or reference) can also give significant progress. Improved accuracy of the EBI phasor measurement makes the proposed method reliable for most clinical applications. Due to its simplicity, the method is appropriate for on-chip realization in implantable devices

1 June 2008 in Physiological Measurement
Verified
Journal Article
Closed access
MMM Min
M Min
UPU Pliquett
U Pliquett
TNT Nacke
T Nacke
ABA Barthel
A Barthel
PAP Annus
P Annus
RLR Land
R Land
Frequency domain impedance measurements are still the common approach in assessing passive electrical properties of cells and tissues. However, due to the time requirements for sweeping over a frequency range for performing spectroscopy, they are not suited for recovering fast impedance changes of biological objects. The use of broad bandwidth excitation and monitoring the response as a function of time will greatly reduce the measurement time. The widespread usage of a square wave excitation is simple but not always the best choice. Here we consider different waveforms for excitation and discuss not only the advantages but also their limitations. Measurements in a miniaturized chamber where frequency and time domain measurements are compared show the suitability of different waveforms as excitation signals for the measurements of bio-impedance. The chirp excitation has been found to be most promising in terms of frequency range, signal-to-noise ratio and crest factor.

23 July 2007 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MMMart Min
Mart Min
TPToomas Parve
Toomas Parve
ARAnts Ronk
Ants Ronk
PAPaul Annus
Paul Annus
TPToivo Paavle
Toivo Paavle
Direct sampling of known carriers is the preferred digital method for measuring biomodulation of tissue impedance. Due to limited resolution and conversion rate of analog-to-digital converters and limited processing power of available digital processors and/or lack of energy resources, conventional discrete-Fourier-transform-based algorithms are not efficient in small medical devices. Knowing exactly the frequencies of carriers (and excitations), an energy-saving fast signal processing method can be developed and implemented. When sampling synchronously with a carrier, it is possible to minimize the complexity of calculations and to introduce a digital-to-analog feedback for enhancement of resolution by digitizing only the small variations between adjacent samples. The proposed system is qualified on proprietary hardware.

1 January 2000 in Measurement
Verified
Journal Article
Closed access
MMMart Min
Mart Min
OMOlev Märtens
Olev Märtens
TPToomas Parve
Toomas Parve

7 June 2011 in Physiological Measurement
Verified
Journal Article
Closed access
MMM Min
M Min
RLR Land
R Land
TPT Paavle
T Paavle
TPT Parve
T Parve
PAP Annus
P Annus
DTD Trebbels
D Trebbels
An impedance spectrum of dynamic systems is time dependent. Fast impedance changes take place, for example, in high throughput microfluidic devices and in operating cardiovascular systems. Measurements must be as short as possible to avoid significant impedance changes during the spectrum analysis, and as long as possible for enlarging the excitation energy and obtaining a better signal-to-noise ratio (SNR). The authors propose to use specific short chirp pulses for excitation. Thanks to the specific properties of the chirp function, it is possible to meet the needs for a spectrum bandwidth, measurement time and SNR so that the most accurate impedance spectrogram can be obtained. The chirp wave excitation can include thousands of cycles when the impedance changes slowly, but in the case of very high speed changes it can be shorter than a single cycle, preserving the same excitation bandwidth. For example, a 100 kHz bandwidth can be covered by the chirp pulse with durations from 10 µs to 1 s; only its excitation energy differs also 10(5) times. After discussing theoretical short chirp properties in detail, the authors show how to generate short chirps in the microsecond range with a bandwidth up to a few MHz by using digital synthesis architectures developed inside a low-cost standard field programmable gate array.

1 October 2008
Verified
Conference Paper
Closed access
TPToivo Paavle
Toivo Paavle
MMMart Min
Mart Min
TPToomas Parve
Toomas Parve
In this paper, theoretical considerations and simulation results of a method for quick estimation of the bioimpedance (BI)vector over a wide range of excitation frequencies are discussed. This method uses a chirp signal with linearly modulated frequency for excitation. The response signal is processed using cross-correlation techniques together with following fast Fourier transform (FFT). As the result, the complex spectrum of the response signal is attained in the range of frequency, determined by the spread of chirp pulse. This spectrum characterizes the frequency response of the impedance under study.