Mohammed S. M. Elbaz

Mohammed S. M. Elbaz

Auto-generated profile, based on publicly available information

Mohammed S. M. Elbaz

Department of Radiology Northwestern University Feinberg School of Medicine Chicago IL USA

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 March 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
HBHaben Berhane
Haben Berhane
MSMichael Scott
Michael Scott
MEMohammed Elbaz
Mohammed Elbaz
KJKelly Jarvis
Kelly Jarvis
PMPatrick McCarthy
Patrick McCarthy
MMMichael Markl
Michael Markl

27 September 2014 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
MEMohammed S M Elbaz
Mohammed S M Elbaz
ECEmmeline E Calkoen
Emmeline E Calkoen
JWJos JM Westenberg
Jos JM Westenberg
BLBoudewijn P F Lelieveldt
Boudewijn P F Lelieveldt
ARArno A W Roest
Arno A W Roest
RGRob J van der Geest
Rob J van der Geest
LV diastolic vortex formation has been suggested to critically contribute to efficient blood pumping function, while altered vortex formation has been associated with LV pathologies. Therefore, quantitative characterization of vortex flow might provide a novel objective tool for evaluating LV function. The objectives of this study were 1) assess feasibility of vortex flow analysis during both early and late diastolic filling in vivo in normal subjects using 4D Flow cardiovascular magnetic resonance (CMR) with retrospective cardiac gating and 3D vortex core analysis 2) establish normal quantitative parameters characterizing 3D LV vortex flow during both early and late ventricular filling in normal subjects. With full ethical approval, twenty-four healthy volunteers (mean age: 20±10 years) underwent whole-heart 4D Flow CMR. The Lambda2-method was used to extract 3D LV vortex ring cores from the blood flow velocity field during early (E) and late (A) diastolic filling. The 3D location of the center of vortex ring core was characterized using cylindrical cardiac coordinates (Circumferential, Longitudinal (L), Radial (R)). Comparison between E and A filling was done with a paired T-test. The orientation of the vortex ring core was measured and the ring shape was quantified by the circularity index (CI). Finally, the Spearman’s correlation between the shapes of mitral inflow pattern and formed vortex ring cores was tested. Distinct E- and A-vortex ring cores were observed with centers of A-vortex rings significantly closer to the mitral valve annulus (E-vortex L=0.19±0.04 versus A-vortex L=0.15±0.05; p=0.0001), closer to the ventricle’s long-axis (E-vortex: R=0.27±0.07, A-vortex: R=0.20±0.09, p=0.048) and more elliptical in shape (E-vortex: CI=0.79±0.09, A-vortex: CI=0.57±0.06; <0.001) compared to E-vortex. The circumferential location and orientation relative to LV long-axis for both E- and A-vortex ring cores were similar. Good to strong correlation was found between vortex shape and mitral inflow shape through both the annulus (r=0.66) and leaflet tips (r=0.83). Quantitative characterization and comparison of 3D vortex rings in LV inflow during both early and late diastolic phases is feasible in normal subjects using retrospectively-gated 4D Flow CMR, with distinct differences between early and late diastolic vortex rings.

28 February 2016 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
MEMohammed S.M. Elbaz
Mohammed S.M. Elbaz
RGRob J van der Geest
Rob J van der Geest
ECEmmeline E. Calkoen
Emmeline E. Calkoen
ARAlbert de Roos
Albert de Roos
BLBoudewijn P.F. Lelieveldt
Boudewijn P.F. Lelieveldt
JWJos J.M. Westenberg
Jos J.M. Westenberg
Purpose: To evaluate viscous energy loss and the association with three‐dimensional (3D) vortex ring formation in left ventricular (LV) blood flow during diastolic filling.Theory and Methods: Thirty healthy volunteers were compared with 32 patients with corrected atrioventricular septal defect as unnatural mitral valve morphology and inflow are common in these patients. 4DFlow MRI was acquired from which 3D vortex ring formation was identified in LV blood flow at peak early (E)‐filling and late (A)‐filling and characterized by its presence/absence, orientation, and position from the lateral wall. Viscous energy loss was computed over E‐filling, A‐filling, and complete diastole using the Navier‐Stokes energy equations.Results: Compared with healthy volunteers, viscous energy loss was significantly elevated in patients with disturbed vortex ring formation as characterized by a significantly inclined orientation and/or position closer to the lateral wall. Highest viscous energy loss was found in patients without a ring‐shaped vortex during E‐filling (on average more than double compared with patients with ring‐shape vortex, P < 0.003). Altered A‐filling vortex ring formation was associated with significant increase in total viscous energy loss over diastole even in the presence of normal E‐filling vortex ring.Conclusion: Altered vortex ring formation during LV filling is associated with increased viscous energy loss. Magn Reson Med 77:794–805, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.

1 February 2018 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
PGPankaj Garg
Pankaj Garg
SCSaul Crandon
Saul Crandon
PSPeter Swoboda
Peter Swoboda
GFGraham J. Fent
Graham J. Fent
JFJames R. J. Foley
James R. J. Foley
EDErica Dall'ARmellina
Erica Dall'ARmellina
Myocardial infarction (MI) leads to complex changes in left ventricular (LV) haemodynamics that are linked to clinical outcomes. We hypothesize that LV blood flow kinetic energy (KE) is altered in MI and is associated with LV function and infarct characteristics. This study aimed to investigate the intra-cavity LV blood flow KE in controls and MI patients, using cardiovascular magnetic resonance (CMR) four-dimensional (4D) flow assessment. Forty-eight patients with MI (acute-22; chronic-26) and 20 age/gender-matched healthy controls underwent CMR which included cines and whole-heart 4D flow. Patients also received late gadolinium enhancement imaging for infarct assessment. LV blood flow KE parameters were indexed to LV end-diastolic volume and include: averaged LV, minimal, systolic, diastolic, peak E-wave and peak A-wave KEiEDV. In addition, we investigated the in-plane proportion of LV KE (%) and the time difference (TD) to peak E-wave KE propagation from base to mid-ventricle was computed. Association of LV blood flow KE parameters to LV function and infarct size were investigated in all groups. LV KEiEDV was higher in controls than in MI patients (8.5 ± 3 μJ/ml versus 6.5 ± 3 μJ/ml, P = 0.02). Additionally, systolic, minimal and diastolic peak E-wave KEiEDV were lower in MI (P < 0.05). In logistic-regression analysis, systolic KEiEDV (Beta = − 0.24, P < 0.01) demonstrated the strongest association with the presence of MI. In multiple-regression analysis, infarct size was most strongly associated with in-plane KE (r = 0.5, Beta = 1.1, P < 0.01). In patients with preserved LV ejection fraction (EF), minimal and in-plane KEiEDV were reduced (P < 0.05) and time difference to peak E-wave KE propagation during diastole increased (P < 0.05) when compared to controls with normal EF. Reduction in LV systolic function results in reduction in systolic flow KEiEDV. Infarct size is independently associated with the proportion of in-plane LV KE. Degree of LV impairment is associated with TD of peak E-wave KE. In patient with preserved EF post MI, LV blood flow KE mapping demonstrated significant changes in the in-plane KE, the minimal KEiEDV and the TD. These three blood flow KE parameters may offer novel methods to identify and describe this patient population.

1 December 2017 in International Journal of Cardiology
Verified
Journal Article
Open access
SCSaul Crandon
Saul Crandon
MEMohammed S.M. Elbaz
Mohammed S.M. Elbaz
JWJos J.M. Westenberg
Jos J.M. Westenberg
RGRob J van der Geest
Rob J van der Geest
SPSven Plein
Sven Plein
PGPankaj Garg
Pankaj Garg
Four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) is an emerging non-invasive imaging technology used to visualise and quantify intra-cardiac blood flow. The aim of this systematic review is to assess the literature on the current clinical applications of intra-cardiac 4D flow CMR. A systematic review was conducted to evaluate the literature on the intra-cardiac clinical applications of 4D flow CMR. Structured searches were carried out on Medline, EMBASE and the Cochrane Library in October 2016. A modified Critical Skills Appraisal Programme (CASP) tool was used to objectively assess and score the included studies. Studies were categorised as 'highly clinically applicable' for scores of 67-100%, 'potentially clinically applicable' for 34-66% and 'less clinically applicable' for 0-33%. Of the 1608 articles screened, 44 studies met eligibility for systematic review. The included literature consisted of 22 (50%) mechanistic studies, 18 (40.9%) pilot studies and 4 (9.1%) diagnostic studies. Based on the modified CASP tool, 27 (62%) studies were 'highly clinically applicable', 9 (20%) were 'potentially clinically applicable' and 8 (18%) were 'less clinically applicable'. There are many proposed methods for using 4D flow CMR to quantify intra-cardiac flow. The evidence base is mainly mechanistic, featuring single-centred designs. Larger, multi-centre studies are required to validate the proposed techniques and investigate the clinical advantages that 4D flow CMR offers over standard practices. PROSPERO=CRD42016051438.

22 August 2018 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
PGPankaj Garg
Pankaj Garg
RGRob J van der Geest
Rob J van der Geest
PSPeter Swoboda
Peter Swoboda
SCSaul Crandon
Saul Crandon
GFGraham J Fent
Graham J Fent
SPSven Plein
Sven Plein
The main aim of this study was to characterize changes in the left ventricular (LV) blood flow kinetic energy (KE) using four-dimensional (4D) flow cardiovascular magnetic resonance imaging (CMR) in patients with myocardial infarction (MI) with/without LV thrombus (LVT). This is a prospective cohort study of 108 subjects [controls = 40, MI patients without LVT (LVT− = 36), and MI patients with LVT (LVT+ = 32)]. All underwent CMR including whole-heart 4D flow. LV blood flow KE wall calculated using the formula: KE=12 ρblood . Vvoxel . v2⁠, where ρ = density, V = volume, v = velocity, and was indexed to LV end-diastolic volume. Patient with MI had significantly lower LV KE components than controls (P < 0.05). LVT+ and LVT− patients had comparable infarct size and apical regional wall motion score (P > 0.05). The relative drop in A-wave KE from mid-ventricle to apex and the proportion of in-plane KE were higher in patients with LVT+ compared with LVT− (87 ± 9% vs. 78 ± 14%, P = 0.02; 40 ± 5% vs. 36 ± 7%, P = 0.04, respectively). The time difference of peak E-wave KE demonstrated a significant rise between the two groups (LVT−: 38 ± 38 ms vs. LVT+: 62 ± 56 ms, P = 0.04). In logistic-regression, the relative drop in A-wave KE (beta = 11.5, P = 0.002) demonstrated the strongest association with LVT. Patients with MI have reduced global LV flow KE. Additionally, MI patients with LVT have significantly reduced and delayed wash-in of the LV. The relative drop of distal intra-ventricular A-wave KE, which represents the distal late-diastolic wash-in of the LV, is most strongly associated with the presence of LVT.