David McEneaney

David McEneaney

Auto-generated profile, based on publicly available information

David McEneaney

Cardiovascular Research Unit, Craigavon Area Hospital, Portadown, UK

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2019 in Electronics
Verified
Journal Article
Open access
PDF file
AVAngel Villegas
Angel Villegas
DMDavid McEneaney
David McEneaney
Omar EscalonaOmar Escalona
Omar Escalona
This article presents the devising, development, prototyping and assessment of a wearable arm-ECG sensor system (WAMECG1) for long-term non-invasive heart rhythm monitoring, and functionalities for acquiring, storing, visualizing and transmitting high-quality far-field electrocardiographic signals. The system integrates the main building blocks present in a typical ECG monitoring device such as the skin surface electrodes, front-end amplifiers, analog and digital signal conditioning filters, flash memory and wireless communication capability. These are integrated into a comfortable, easy to wear, and ergonomically designed arm-band ECG sensor system which can acquire a bipolar ECG signal from the upper arm of the user over a period of 72 h. The small-amplitude bipolar arm-ECG signal is sensed by a reusable, long-lasting, Ag–AgCl based dry electrode pair, then digitized using a programmable sampling rate in the range of 125 to 500 Hz and transmitted via Wi-Fi. The prototype comparative performance assessment results showed a cross-correlation value of 99.7% and an error of less than 0.75% when compared to a reference high-resolution medical-grade ECG system. Also, the quality of the recorded far-field bipolar arm-ECG signal was validated in a pilot trial with volunteer subjects from within the research team, by wearing the prototype device while: (a) resting in a chair; and (b) doing minor physical activities. The R-peak detection average sensibilities were 99.66% and 94.64%, while the positive predictive values achieved 99.1% and 92.68%, respectively. Without using any additional algorithm for signal enhancement, the average signal-to-noise ratio (SNR) values were 21.71 and 18.25 for physical activity conditions (a) and (b) respectively. Therefore, the performance assessment results suggest that the wearable arm-band prototype device is a suitable, self-contained, unobtrusive platform for comfortable cardiac electrical activity and heart rhythm logging and monitoring.

1 March 2014 in Resuscitation
Verified
Journal Article
Closed access
AHAndrew Howe
Andrew Howe
Omar EscalonaOmar Escalona
Omar Escalona
RMRebecca Di Maio
Rebecca Di Maio
BMBertrand Massot
Bertrand Massot
NCNick A. Cromie
Nick A. Cromie
DMDavid J. McEneaney
David J. McEneaney

1 September 2015 in Cardiology in Review
Verified
Journal Article
Closed access
MCM. Connolly
M. Connolly
DMD. McEneaney
D. McEneaney
IMIan Menown
Ian Menown
NMN. Morgan
N. Morgan
MHM. Harbinson
M. Harbinson
Acute kidney injury (AKI), defined as a rise in serum creatinine of greater than 25% from baseline measured at 48 hours after renal insult, may follow iodinated contrast coronary angiography. Termed contrast-induced nephropathy, it can result in considerable morbidity and mortality. Measurement of serum creatinine as a functional biomarker of glomerular filtration rate is widely used for detection of AKI, but it lacks sensitivity for the early diagnosis of AKI (typically rising 24 hours after functional loss) and, as a solely functional marker of glomerular filtration rate, is unable to differentiate among the various causes of AKI. These intrinsic limitations to creatinine measurement and the recognition that improved clinical outcomes are linked to a more timely diagnosis of AKI, has led investigators to search for novel biomarkers of "early" kidney injury. Several studies have investigated the utility of renal injury biomarkers in a variety of clinical settings including angiography/percutaneous coronary intervention, coronary artery bypass graft surgery, sepsis in intensive care patients, and pediatric cardiac surgery. In this article, we discuss the use of iodinated contrast for coronary procedures and the risk factors for contrast-induced nephropathy, followed by a review the potential diagnostic utility of several novel biomarkers of early AKI in the clinical settings of coronary angiography/percutaneous coronary intervention. In particular, we discuss neutrophil gelatinase associated lipocalin in depth. If validated, such biomarkers would facilitate earlier AKI diagnosis and improve clinical outcomes.

4 October 2012 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Closed access
PDF file
VKVivek N. Kodoth
Vivek N. Kodoth
EHEmily C. Hodkinson
Emily C. Hodkinson
RNRebecca L. Noad
Rebecca L. Noad
KAKyle P. Ashfield
Kyle P. Ashfield
NCNicholas A. Cromie
Nicholas A. Cromie
MRMichael J. D. Roberts
Michael J. D. Roberts

26 June 2013 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
WLWilliam David Lynn
William David Lynn
Omar EscalonaOmar Escalona
Omar Escalona
DMD J McEneaney
D J McEneaney

31 March 2011 in Public Health Nutrition
Verified
Journal Article
Open access
DMDara F McEneaney
Dara F McEneaney
SLSusan C Lennie
Susan C Lennie
Objective: To determine whether video-based instructions improve the accuracy of self-measures of waist and hip circumference compared with written instructions.Design: Population-based, cross-sectional study. Self-measurements of waist circumference (WC) and hip circumference (HC) of fifty-seven participants randomly allocated to receive either written instruction or video instruction were compared with those of a trained technician.Setting: Aberdeen, Scotland, and Brussels, Belgium, between February and April 2010.Subjects: Adults aged 18–62 years with a high level of English language and no prior training in anthropometry.Results: WC was significantly overestimated by the written method (1·75 cm bias; P = 0·007) but not the video method (0·95 cm bias; P = 0·239). HC was significantly underestimated in both written (−0·35 cm bias; P = 0·009) and video methods (−0·75 cm bias; P = 0·046). Reliability was not significantly affected by age, sex, BMI or WC. Bland–Altman plots demonstrated wide limits of agreement for WC (−6·83, 6·08 cm for written method; −10·14, 6·72 cm for video method) and HC (−12·85, 1·60 cm for written method; −10·82, 2·50 cm for video method).Conclusions: Video technology can support more accurate self-measurements of anthropometric data in epidemiological studies. Further research is warranted using larger and more heterogeneous samples in order that results can be generalised.