Wenting Bu

Wenting Bu

Auto-generated profile, based on publicly available information

Wenting Bu

Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2018 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
WBWenting Bu
Wenting Bu
YNYouyi Ni
Youyi Ni
GSGeorg Steinhauser
Georg Steinhauser
WZWang Zheng
Wang Zheng
JZJian Zheng
Jian Zheng
NFNaoki Furuta
Naoki Furuta
The Fukushima nuclear accident caused the release of large amounts of radionuclides into the environment. After the accident, radioactive contamination assessment in environmental samples is essential for radiation dose estimation and radioactive remediation. Mass spectrometry characterized by high sensitivity, low detection limit, short measuring time, high sample throughput, and the capability to obtain atomic ratios is a promising technique for the analysis of the accident released long-lived radionuclides. This review describes the developed analytical methods based on mass spectrometric techniques for the determination of radionuclides (Pu isotopes, U isotopes, radiocesium, radioiodine, radiostrontium, etc.) with regards to Fukushima samples. The real applications of mass spectrometric techniques for radioactive source identification, radiation protection and geochemical tracing are discussed to highlight the importance of mass spectrometric techniques in radioactive contamination assessment after the accident. Future research prospects of mass spectrometric techniques for the analysis of radionuclides with application to Fukushima samples are briefly outlined.

7 December 2018 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
WBWenting Bu
Wenting Bu
LTLei Tang
Lei Tang
XLXuemei Liu
Xuemei Liu
ZWZhongtang Wang
Zhongtang Wang
MFMiho Fukuda
Miho Fukuda
XWXiaolin Wang
Xiaolin Wang
A new method was developed for determination of the 135Cs/137Cs isotopic ratio at the femtogram level in environmental samples.

1 October 2021 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
WBWenting Bu
Wenting Bu
MGMei Gu
Mei Gu
XDXiaotong Ding
Xiaotong Ding
YNYouyi Ni
Youyi Ni
XSXuepeng Shao
Xuepeng Shao
SHSheng Hu
Sheng Hu
The monitoring of Pu isotopes in environmental samples was essential for radioactive assessment and tracing the geochemical processes. Triple quadrupole inductively coupled plasma mass spectrometry (ICP-MS/MS) has shown strong ability for long-half lived radionuclide analysis with respect to interference removal capability. In this study, we explored the ability of ICP-MS/MS for the ultra-trace determination of Pu isotopes in environmental samples. The Pu sensitivity was improved more than 10 times by using an APEX-Ω high efficiency sample introduction system. The absolute detection limits for 239Pu and 240Pu were about 0.13 fg (0.0003 mBq) and 0.08 fg (0.0007 mBq), respectively. After the introduction of NH3 and He into the reaction cell with appropriate gas flow rates, the U hydride removal capability (UH+/U+: 1.2 × 10−6) was improved, while the Pu sensitivity (7400 cps ppt−1) was still remarkable. A simple one stage chromatographic separation method with a suitable Pu eluent was established for the separation of Pu from soil and sediment samples. The sample matrix effect and the UH+ interference were eliminated with the coupling of the separation procedure and the ICP-MS/MS detection method. Several reference materials were analyzed for the validation of the method. The results revealed that our method was suitable for the determination of Pu isotopes in environmental samples.

11 August 2021 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
XDXiaotong Ding
Xiaotong Ding
WBWenting Bu
Wenting Bu
YNYouyi Ni
Youyi Ni
XSXuepeng Shao
Xuepeng Shao
KXKe Xiong
Ke Xiong
SHSheng Hu
Sheng Hu
A method for the determination of REEs in uranium ore samples by ICP-MS/MS with O 2 reaction and mass-shift detection.

27 January 2020 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
XSXuepeng Shao
Xuepeng Shao
WBWenting Bu
Wenting Bu
YFYichen Fan
Yichen Fan
KLKaiming Long
Kaiming Long
HYHongmei Yang
Hongmei Yang
FHFanhua Hao
Fanhua Hao
A new method is presented for high-precision measurement of cerium isotope ratios in geological samples by TIMS with the Ce + technique.

30 April 2022 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
WBWenting Bu
Wenting Bu
LYLiang Yang
Liang Yang
LTLei Tang
Lei Tang
KXKe Xiong
Ke Xiong
YNYouyi Ni
Youyi Ni
SHSheng Hu
Sheng Hu
The introduction of O2 for the elimination of Mo interference for Tc measurement by ICP-MS/MS.