Geoffrey H. White

Geoffrey H. White

Auto-generated profile, based on publicly available information

Geoffrey H. White

Department of Vascular Surgery, Royal Prince Alfred Hospital, University of Sydney, Australia

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 1998 in Journal of Endovascular Surgery
Verified
Journal Article
Closed access
GWGeoffrey H. White
Geoffrey H. White
JMJames May
James May
RWRichard C. Waugh
Richard C. Waugh
XCXavier Chaufour
Xavier Chaufour
WYWeiyun Yu
Weiyun Yu
The Journal of Endovascular Therapy (formerly the Journal of Endovascular Surgery ) was established in 1994 as a forum for all physicians, scientists, and al...

1 November 1999 in Journal of Endovascular Surgery
Verified
Journal Article
Closed access
GWGeoffrey H. White
Geoffrey H. White
JMJames May
James May
PPPaul Petrasek
Paul Petrasek
RWRichard Waugh
Richard Waugh
MSMichael Stephen
Michael Stephen
JHJohn Harris
John Harris
The Journal of Endovascular Therapy (formerly the Journal of Endovascular Surgery ) was established in 1994 as a forum for all physicians, scientists, and al...

1 May 1997 in Journal of Endovascular Surgery
Verified
Journal Article
Closed access
GWGeoffrey H. White
Geoffrey H. White
WYWeiyun Yu
Weiyun Yu
JMJames May
James May
RWRichard Waugh
Richard Waugh
XCXavier Chaufour
Xavier Chaufour
MSMichael S. Stephen
Michael S. Stephen
To report a > 3-year experience with a modular, balloon-expandable endovascular graft used for aneurysm exclusion in the aorta and other arteries. The customized White-Yu Endovascular GAD Graft, a woven polyester prosthesis with an intrinsic Elgiloy wire graft attachment system along the body of the graft, is a flexible endograft design available in straight, tapered, and bifurcated versions that can be delivered transluminally through 18F to 24F sheaths. Since July 1993, 93 patients have received the White-Yu endograft for treatment of 76 abdominal aortic, 3 thoracic aortic, 13 iliac, and 1 popliteal aneurysms. Of the 79 aortic procedures, 39 involved straight tube grafts, 20 were tapered aortoiliac models, and 20 were bifurcated devices. Success rates for tube grafts were 81% in the abdominal aorta and 100% for the thoracic aorta; 5 primary endoleaks (14%) and 2 conversions to surgery (5.6%) occurred with this graft type. Aortoiliac grafts were deployed successfully in 95% (19/20) of cases with 1 conversion (5%) due to thrombosis. Seventy-five percent of the bifurcated endograft procedures were successful, with 4 conversions (20%) for technical failures and 1 graft thrombosis. Four additional endografts were deployed to treat two primary and two secondary endoleaks in tube graft patients. Two access-related arterial injuries were treated surgically. There was one case of embolus to the distal femoral artery but no microembolization. Overall perioperative (30-day) mortality was 3.1%. Over a mean 18-month follow-up (range 2 to 39), no late graft thrombosis, stenosis, or graft migration has been seen on CT scans or X ray. Endoleak has not been detected in any aortoiliac or bifurcated graft. Aneurysm size has diminished consistently in successfully treated cases. The White-Yu endograft appears to offer a safe, efficacious, and minimally invasive means of excluding aneurysms from the circulation. Improvements in patient selection, surgical techniques, and equipment have reduced the incidence of endoleak and conversion to open repair over the course of the evaluation.

1 May 1997 in Journal of Endovascular Surgery
Verified
Journal Article
Closed access
JMJames May
James May
GWGeoffrey H. White
Geoffrey H. White
WYWeiyun Yu
Weiyun Yu
RWRichard Waugh
Richard Waugh
MSMichael S. Stephen
Michael S. Stephen
JHJohn P. Harris
John P. Harris
The Journal of Endovascular Therapy (formerly the Journal of Endovascular Surgery ) was established in 1994 as a forum for all physicians, scientists, and al...

1 November 1998 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
GWGeoffrey H. White
Geoffrey H. White
JMJames May
James May
RWRichard C. Waugh
Richard C. Waugh
XCXavier Chaufour
Xavier Chaufour
WYWeiyun Yu
Weiyun Yu
In this document the authors continue to refine their seminal categorization of endoleak, a major complication of endovascular aneurysm repair. In addition to type I (related to the graft device itself) and type II (retrograde flow from collateral branches) endoleak, they propose two new categories: endoleak due to fabric tears, graft disconnection, or disintegration would be classified type III, and flow through the graft presumed to be associated with graft wall “porosity” would be categorized as type IV endoleak.

1 November 1999 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
GWGeoffrey H. White
Geoffrey H. White
JMJames May
James May
PPPaul Petrasek
Paul Petrasek
RWRichard Waugh
Richard Waugh
MSMichael Stephen
Michael Stephen
JHJohn Harris
John Harris
Purpose: To present and analyze several cases that illustrate persistent sac pressurization following endovascular abdominal aortic aneurysm (AAA) repair. Methods and Results: Four patients with successful endovascular AAA exclusion presented in follow-up with an expanding aneurysm. Two had initial sac diameter decrease, but by 18 and 24 months, respectively, the AAA had enlarged and become pulsatile. There was no endoleak evident, but the proximal attachment stents had migrated distally in both cases. One patient developed endoleak with aneurysm expansion at 6 months; contained rupture occurred at 12 months. The last case had slowly evolving aneurysm expansion over 36 months but no endoleak. All endografts were removed and successfully replaced with conventional grafts. Intrasac thrombus was implicated as the means of pressure transmission that precipitated AAA expansion in these cases. Conclusions: Excluded AAAs can increase in size owing to persistent or recurrent pressurization (endotension) of the sac even when there is no evidence of endoleak. One proposed mechanism is pressure transmission via thrombus that lines the attachment site. Endotension may also represent an indiscernible, very low flow endoleak that allows blood to clot at the source of leakage.