Prakash Chittora

Prakash Chittora

Auto-generated profile, based on publicly available information

Prakash Chittora

Electrical Engineering, Delhi Technological University, Delhi, India

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2018 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
PCPrakash Chittora
Prakash Chittora
ASAlka Singh
Alka Singh
MSMadhusudan Singh
Madhusudan Singh
Load current may become highly distorted in a weak power system network due to the presence of non‐linear and dynamic loads. Harmonics get penetrated into the supply system too; thereby making it polluted and rich in harmonic content and causing a detrimental effect on the performance of other connected loads. In such cases, the conventional control algorithms fail to work effectively to mitigate power quality (PQ) issues. This study addresses solutions to PQ issues which get aggravated in the presence of distorted supply. This study proposes a multiple complex coefficient filter (MCCF)‐second‐order generalised integrator (SOGI)‐based controller designed to effectively compensate for PQ problems associated with weak grid. A MCCF filter is designed to extract the fundamental components of grid voltage used further for grid synchronisation. The SOGI is designed to extract the fundamental active current magnitude of the load current and reduce PQ issues with the help of Distributed Static Compensator (DSTATCOM). Neutral current compensation is achieved with an appropriately designed zigzag transformer. Extensive simulation and hardware results realising dSPACE 1104 as Digital Signal Processor are considered in this study to show that the performance of the proposed control algorithm under PQ issues with distorted grid.

15 January 2018 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
PCPrakash Chittora
Prakash Chittora
ASAlka Singh
Alka Singh
MSMadhusudan Singh
Madhusudan Singh
Three-phase four-wire (TPFW) distribution systems are prone to various power quality issues such as voltage fluctuations, poor power factor, unbalanced load conditions and the presence of harmonics in current. Mitigation of these power quality (PQ) problems using appropriate shunt compensator requires advanced control algorithms for control of three phase voltage source converters (VSC) in distribution system. In this paper, Chebyshev functional expansion based Artificial Neural Network (ChANN) algorithm for shunt compensation using Distribution Static Compensator (DSTATCOM) is proposed. The parameters of ChANN are trained in real time. Implementation results with linear and non-linear loads are demonstrated on a prototype hardware designed and developed using dSPACE 1104, current and voltage sensors for the realization of DSTATCOM for TPFW system. A zigzag transformer is used along with conventional three-phase, three-wire (TPTW) DSTATCOM to reduce its overall rating. Suitable comparisons with conventional control techniques are also mentioned.

8 March 2024 in Electrical Engineering
Verified
Journal Article
Closed access
PDF file
SKSombir Kundu
Sombir Kundu
MSMadhusudan Singh
Madhusudan Singh
AGashutosh giri
ashutosh giri
SKSunil Kadiyan
Sunil Kadiyan
PCPrakash Chittora
Prakash Chittora
DSDivyansh Shailly
Divyansh Shailly

19 March 2024 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
CKChandan Kumar
Chandan Kumar
PCPrakash Chittora
Prakash Chittora

6 March 2017 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
PCPrakash Chittora
Prakash Chittora
ASAlka Singh
Alka Singh
MSMadhusudan Singh
Madhusudan Singh
Three‐phase, four‐wire systems are prone to various power quality (PQ) problems such as load unbalancing, low power factor, harmonics and problem of neutral current. Modified recursive Gauss–Newton (MRGN) algorithm is proposed to mitigate various PQ problems in four‐wire distribution systems. The recursive Gauss–Newton method is quite complex, so it is modified to obtain simple and fast MRGN control technique. The proposed algorithm is developed using MATLAB/Simulink environment and tested for mitigation of various PQ problems. Thereafter, a hardware prototype for shunt active power filter (SAPF) is developed along with various sensors, control circuits using dspace 1104 as digital signal processor. Gating circuits provide proper gating pulses to control SAPF as per the new algorithm. Results with linear and non‐linear loads have been tested under a variety of loading conditions and thoroughly analysed for its performance.