Edgardo Leon-Salguero

Edgardo Leon-Salguero

Auto-generated profile, based on publicly available information

Edgardo Leon-Salguero

Departamento de Ingeniería Química y Metalurgia de la Universidad de Sonora, Unidad Regional Centro, Campus Hermosillo

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2019 in Nano Energy
Verified
Journal Article
Closed access
GMGonzalo Murillo
Gonzalo Murillo
ELEdgardo Leon-Salguero
Edgardo Leon-Salguero
Paulina Martinez-AlanisPaulina Martinez-Alanis
Paulina Martinez-Alanis
JEJaume Esteve
Jaume Esteve
Josefina Alvarado RiveraJosefina Alvarado Rivera
Josefina Alvarado Rivera
FGFrank Güell
Frank Güell

21 April 2019 in Sensors
Verified
Journal Article
Open access
PDF file
MDMarcos Duque Duque
Marcos Duque Duque
ELEdgardo Leon-Salguero
Edgardo Leon-Salguero
JSJordi Sacristan
Jordi Sacristan
JEJaume Esteve
Jaume Esteve
GMGonzalo Murillo
Gonzalo Murillo
The increasing interest in the Internet of Things (IoT) has led to the rapid development of low-power sensors and wireless networks. However, there are still several barriers that make a global deployment of the IoT difficult. One of these issues is the energy dependence, normally limited by the capacitance of the batteries. A promising solution to provide energy autonomy to the IoT nodes is to harvest residual energy from ambient sources, such as motion, vibrations, light, or heat. Mechanical energy can be converted into electrical energy by using piezoelectric transducers. The piezoelectric generators provide an alternating electrical signal that must be rectified and, therefore, needs a power management circuit to adapt the output to the operating voltage of the IoT devices. The bonding and packaging of the different components constitute a large part of the cost of the manufacturing process of microelectromechanical systems (MEMS) and integrated circuits. This could be reduced by using a monolithic integration of the generator together with the circuitry in a single chip. In this work, we report the optimization, fabrication, and characterization of a vibration-driven piezoelectric MEMS energy harvester, and the design and simulation of a charge-pump converter based on a standard complementary metal–oxide–semiconductor (CMOS) technology. Finally, we propose combining MEMS and CMOS technologies to obtain a fully integrated system that includes the piezoelectric generator device and the charge-pump converter circuit without the need of external components. This solution opens new doors to the development of low-cost autonomous smart dust devices.

7 December 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
MDMarcos Duque Duque
Marcos Duque Duque
ELEdgardo Leon-Salguero
Edgardo Leon-Salguero
JSJordi Sacristan
Jordi Sacristan
JEJaume Esteve
Jaume Esteve
GMGonzalo Murillo
Gonzalo Murillo
One of the main difficulties for a global implantation of the Internet of Things (IoT) is the energy dependence of the nodes, limited by the battery’s lifetime. Energy harvesting seems to be a promising solution to provide energy autonomy to IoT nodes. Power management circuits are needed to collect and store the charges scavenged form the ambient sources. In addition, this circuit needs to adapt the output voltage to power the wireless sensor node. Because of the typical heterogeneity of the system, the cost and difficulties associated to the encapsulation of the CMOS chip and the energy harvester can be important. They could be reduced by using a monolithic integration of both parts in a single chip or package. In this work, we propose a fully monolithically integrated system comprised by a power management circuit, a piezoelectric microgenerator and a storage capacitor. With this solution, which combines MEMS and CMOS technologies, we pave the way to the future development of autonomous smart dust.

1 January 2022 in Coluna/Columna
Verified
Journal Article
Open access
JSJavier Andrés Martínez Silva
Javier Andrés Martínez Silva
AAAlan Rojas Ayala
Alan Rojas Ayala
CBCarlos Josué Victoria Buitimea
Carlos Josué Victoria Buitimea
ESEdgardo Leon Salguero
Edgardo Leon Salguero
MBMyrna Cosette Valenzuela Beltran
Myrna Cosette Valenzuela Beltran
Objective: In traumatic injuries of the thoracic spine, three variables are analyzed to make decisions: morphology of the injury, posterior ligamentous complex and neurological status; currently the fourth column is not evaluated; our objective was to determine the biomechanical behavior of the spine with a fracture of the fifth thoracic vertebral body when accompanied by a short oblique fracture of the sternum. Methods: An anonymous model of a healthy 25-year-old male was used, from which the thoracic spine and rib cage were obtained; in addition to the ligaments of the posterior complex and the intervertebral discs, four models were simulated. An axial section was made, a load of 400 N was applied, and the biomechanical behavior of each model was determined. Results: The area that suffered the most stress at the vertebral level was the posterior column of T4-T5 (tensile strength of 747 MPa), which exceeded the plastic limit, the load through the ribs was distributed from the first to the sixth (100 MPa), in the sternum the stress increased (200 MPa), the deformity increased to 45 mm. Conclusions: The sternum was a fundamental part of the spine’s stability; the combined injury severely increased the stress (8 MPa to 747 MPa) in the spine and exceeded the plastic limit, which generated an instability that is represented by the global deformity acquired (1 mm to 45 mm). Level of evidence II; Prospective comparative study.

18 April 2012 in Smart Materials Research
Verified
Journal Article
Open access
PDF file
EFE. M. A. Fuentes-Fernandez
E. M. A. Fuentes-Fernandez
WDW. Debray-Mechtaly
W. Debray-Mechtaly
MQM. A. Quevedo-Lopez
M. A. Quevedo-Lopez
BGB. Gnade
B. Gnade
ELE. Leon-Salguero
E. Leon-Salguero
HAH. N. Alshareef
H. N. Alshareef
A complete analysis of the morphology, crystallographic orientation, and resulting electrical properties of Pb(Zr0.53,Ti0.47) Pb(Nb1/3, Zn2/3)O3 (PZT-PZN) thin films, as well as the electrical behavior when integrated in a cantilever for energy harvesting applications, is presented. The PZT-PZN films were deposited using sol-gel methods. We report that using 20% excess Pb, a nucleation layer of PbTiO3 (PT), and a fast ramp rate provides large grains, as well as denser films. The PZT-PZN is deposited on a stack of TiO2/PECVD SiO2/Si3N4/thermal SiO2/Poly-Si/Si. This stack is designed to allow wet-etching the poly-Si layer to release the cantilever structures. It was also found that the introduction of the poly-Si layer results in larger grains in the PZT-PZN film. PZT-PZN films with a dielectric constant of 3200 and maximum polarization of 30 μC/cm2 were obtained. The fabricated cantilever devices produced ~300–400 mV peak-to-peak depending on the cantilever design. Experimental results are compared with simulations.

25 September 2025 in REMUS - Revista Estudiantil de Medicina de la Universidad de Sonora
Verified
Journal Article
Open access
PDF file
EREdwin A. Ruelas-Estrada
Edwin A. Ruelas-Estrada
JGJuan Guzmán-García
Juan Guzmán-García
LFLennin E. Figueroa-Gil
Lennin E. Figueroa-Gil
JRJoshua A. Romero-Andrade
Joshua A. Romero-Andrade
ELEdgardo U. León-Salguero
Edgardo U. León-Salguero
Las discapacidades motoras derivadas de enfermedades neuromusculares afectan significativamente la calidad de vida de los pacientes. En este trabajo se propone un modelo híbrido CNN-LSTM con enfoque regresivo para estimar en tiempo real el ángulo articular del codo a partir de señales electromiográficas superficiales (sEMG), con el objetivo de controlar de forma precisa y continua una órtesis robótica. Se emplearon señales sEMG de bíceps y tríceps de una base de datos validada, las cuales fueron sometidas a un riguroso preprocesamiento. El modelo fue entrenado y evaluado utilizando métricas como MAE (0.0828), RMSE (0.1132), R² (0.9517) y coeficiente de Pearson (0.9757), evidenciando alta precisión y robustez. Además, se desarrolló una interfaz gráfica para visualizar las señales y predicciones en tiempo real. Los resultados confirman la viabilidad del enfoque propuesto para aplicaciones clínicas, destacando su potencial para mejorar la rehabilitación funcional del miembro superior y promover la autonomía del paciente mediante un control intuitivo de órtesis activas.