Ekaterina D. Belyakova

Ekaterina D. Belyakova

Auto-generated profile, based on publicly available information

Ekaterina D. Belyakova

Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 April 2024 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
Denis LeonovDenis Leonov
Denis Leonov
ANAnastasia Nasibullina
Anastasia Nasibullina
VGVeronika Grebennikova
Veronika Grebennikova
OVOlga Vlasova
Olga Vlasova
YBYulia Bulgakova
Yulia Bulgakova
YVYuriy Vasilev
Yuriy Vasilev

2 July 2024 in Digital Diagnostics
Verified
Journal Article
Open access
PDF file
EBEkaterina D. Belyakova
Ekaterina D. Belyakova
ANAnastasia A. Nasibullina
Anastasia A. Nasibullina
JBJulia V. Bulgakova
Julia V. Bulgakova
OVOlga V. Vlasova
Olga V. Vlasova
VGVeronika V. Grebennikova
Veronika V. Grebennikova
ПВПетряйкин Алексей Владимирович
Петряйкин Алексей Владимирович
BACKGROUND: The knee joint is a frequently visualized anatomical region in clinical practice. Accurate interpretation of CT scans necessitates a comprehensive understanding of anatomy and a sound grasp of fundamental technical principles and imaging protocols. To safeguard the patient's well-being, it is of paramount importance to prevent erroneous studies resulting from suboptimal equipment quality, setup issues, and patient positioning. These difficulties can be circumvented by the use of phantoms to pre-adjust the equipment and the provision of training to medical staff in scanning techniques. AIM: The aim of the study was to develop a technique for creating an anthropomorphic medical phantom of the knee joint that would accurately reflect the X-ray density of the corresponding human tissues, thus enabling the use of computed tomography studies. MATERIALS AND METHODS: The knee joint phantom comprises a series of models representing the femur, tibia, fibula, patella, collateral ligaments, lateral and medial menisci, tendon of the quadriceps femoris muscle, anterior and posterior cruciate ligaments, and patellar ligament. Ligament models were 3D-printed from resin, bones were cast from silicone, soft tissues were modeled with a homogeneous structure of silicone-like materials and made by casting into silicone molds. The skin was similarly modeled. In the study, the anode voltage range of the CT scanner varied from 80 to 140 kV, and the slice thickness was equal to 1.25 mm. RESULTS: The developed anthropomorphic knee joint phantom demonstrated the X-ray density of the modeled anatomical structures, with ligaments exhibiting a range of 80–120 units on the Hausfield scale, bones exhibiting a range of 320–370 units, and soft tissues and skin exhibiting a range of 20–60 units. The use of additive technologies made it possible to achieve a high degree of similarity between the phantom forms and the knee joint. Further research may be directed towards the creation of a more complex model of bone tissue, comprising a separate cortical layer and spongy substance. CONCLUSIONS: The use of an anthropomorphic knee phantom allows for the acquisition of high-quality CT images without the need for prior scanning of patients.