15 March 2020 in Open Heart
Objectives Re-do aortic valve surgery carries a higher mortality and morbidity compared with first time aortic valve replacement (AVR) and often requires concomitant complex procedures. Transcatheter aortic valve replacement (TAVR) is an option for selective patients. The aim of this study is to present our experience with re-do aortic valve procedures and give an insight into the characteristics of these patients and their outcomes. Methods Retrospective review of 80 consecutive re-do aortic valve procedures. Results Mean patients’ age was 51.80±18.73 years. Aortic regurgitation (AR) was present in 51 (65.4%) patients and aortic stenosis (AS) in 38 (48.7%). Indications for reoperation were: infective endocarditis (IE) (23.8%), bioprosthetic degeneration (12.5%), mechanical valve dysfunction (5%), paravalvular leak (6.2%), patient–prosthesis mismatch (3.8%), native valve disease (25%), aortic aneurysm, pseudoaneurysm and dissection (35%), aortic root/homograft degeneration (27.5%). Forty-one (51.2%) patients underwent re-do AVR, 39 (48.8%) re-do complex aortic valve surgery (28 root, 23 ascending aorta and 6 hemiarch procedures) and 37.5% concomitant procedures. A bioprosthesis was implanted in 43.8%, a mechanical valve in 37.5%, a composite graft in 2.5%, a Biovalsalva graft in 6.2% and a homograft in 10% of patients. In-hospital mortality was 3.8% and incidence of major complications was low. Conclusions A significant proportion of patients were young (61%<60 y), required complex aortic procedures (49%) or presented with contraindications for TAVR (mechanical valve, AR, IE, proximal aortic disease, need for concomitant surgery). Re-do aortic surgery remains the only treatment for such challenging cases and can be performed with acceptable mortality and morbidity in a specialised aortic centre.
1 February 2010 in Asian Cardiovascular and Thoracic Annals
Stentless aortic bioprostheses have been successfully used for over a decade. The 3f bioprosthesis is a new equine pericardial stentless valve, unique in its tubular design, preserving the native aortic sinuses post-implant. Forty-six consecutive aortic valve replacements with the 3f bioprosthesis were performed between June 2003 and January 2005. The patients were prospectively assessed and echocardiography was performed at 6 months, 12 months, and annually thereafter. The median follow-up was 2.1 ± 0.9 years. There was one early and 4 late deaths; none were valve-related. The 2-year mean transvalvular gradient was 8.8 ± 3.8 mm Hg, the mean echocardiographic aortic regurgitation grade was 0.4 ± 0.7 (grade 1 being trivial). Echocardiographic sizing of the aortic annulus before surgery accurately predicted prosthesis size. The 3f bioprosthesis is easy to implant. Early clinical results are favorable, with hemodynamic profiles consistent with those of other stentless prostheses. Longer follow-up is required to confirm its durability.
23 December 2016 in Frontiers of Medicine
1 September 2020 in Asian Cardiovascular and Thoracic Annals
Based on current guidelines, 15% to 20% of patients undergoing mitral valve repair for regurgitation develop left ventricular dysfunction (ejection fraction < 50%–55%) despite a normal baseline. Two schools of thought have been debated: preexisting myocardial disease or suboptimal intraoperative myocardial protection. In our view, they could be reconciled. It is well recognized that left ventricular ejection fraction with a standard cut off at 50%–55% has limited sensitivity in detecting early systolic impairment in mitral regurgitation patients. Mitral regurgitation also leads to mitochondrial oxidative stress, thus rendering the myocardium more susceptible to ischemia-reperfusion injury and precipitating postoperative cardiac dysfunction. The fall in left ventricular ejection fraction early after mitral valve repair was shown to be caused by the reduction in both myocardial contractility and left ventricular stroke volume. To mitigate the risk to myocardial reperfusion injury, appropriate cardioplegia volume and distribution and well-defined surgical repair processes are equally important. We use transesophageal echocardiography-guided cardioplegia delivery, imaging the intramyocardial flow and ensuring adequate protection of the subendocardium during mitral valve repair. Mild aortic regurgitation on a beating heart often leads to left ventricular dilatation with diminished cardioplegia flow in the myocardium, thus requiring direct ostia cardioplegia. Systematic transesophageal echocardiography assessment before surgery is essential for establishing the mitral regurgitation mechanisms and translating them into precise surgical repair strategies. The benefits of transesophageal echocardiography-guided cardioplegia delivery warrant further clinical trials in order to evolve into part of a high surgical standard.
28 May 2021 in Frontiers of Medicine
Over the last half century, surgical aortic valve replacement (SAVR) has evolved to offer a durable and efficient valve haemodynamically, with low procedural complications that allows favourable remodelling of left ventricular (LV) structure and function. The latter has become more challenging among elderly patients, particularly following trans-catheter aortic valve implantation (TAVI). Precise understanding of myocardial adaptation to pressure and volume overloading and its responses to valve surgery requires comprehensive assessments from aortic valve energy loss, valvular-vascular impedance to myocardial activation, force-velocity relationship, and myocardial strain. LV hypertrophy and myocardial fibrosis remains as the structural and morphological focus in this endeavour. Early intervention in asymptomatic aortic stenosis or regurgitation along with individualised management of hypertension and atrial fibrillation is likely to improve patient outcome. Physiological pacing via the His-Purkinje system for conduction abnormalities, further reduction in para-valvular aortic regurgitation along with therapy of angiotensin receptor blockade will improve patient outcome by facilitating hypertrophy regression, LV coordinate contraction, and global vascular function. TAVI leaflet thromboses require anticoagulation while impaired access to coronary ostia risks future TAVI-in-TAVI or coronary interventions. Until comparable long-term durability and the resolution of TAVI related complications become available, SAVR remains the first choice for lower risk younger patients.