Abiyu Kerebo Berekute

Abiyu Kerebo Berekute

Auto-generated profile, based on publicly available information

Abiyu Kerebo Berekute

Institute of Environmental and Occupational Health Sciences, National Yang-Ming Chiao-Tung University, Taipei, 11221, Taiwan; Department of Chemistry, College of Natural and Computational Sciences, Arba Minch University, Arbaminch, Ethiopia

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

4 May 2024 in Journal of Environmental Chemical Engineering
Verified
Journal Article
Closed access
Wonder Nathi DlaminiWonder Nathi Dlamini
Wonder Nathi Dlamini
TYTing-Ching Yao
Ting-Ching Yao
HLHsin-Jui Lee
Hsin-Jui Lee
ABAbiyu Kerebo Berekute
Abiyu Kerebo Berekute
RSRasham Sallah-Ud-Din
Rasham Sallah-Ud-Din
KYKuo-Pin Yu
Kuo-Pin Yu

30 August 2023 in Heliyon
Verified
Journal Article
Open access
WHWei-Wen Huang
Wei-Wen Huang
RSRasham Sallah-Ud-Din
Rasham Sallah-Ud-Din
Wonder Nathi DlaminiWonder Nathi Dlamini
Wonder Nathi Dlamini
ABAbiyu Kerebo Berekute
Abiyu Kerebo Berekute
MGMastewal Endeshaw Getnet
Mastewal Endeshaw Getnet
KYKuo-Pin Yu
Kuo-Pin Yu
Cooking events can generate household air pollutants that deteriorate indoor air quality (IAQ), which poses a threat to human health and well-being. In this study, the emission characteristics and emission factors (EFs) of air pollutants of different meats (beef, lamb, chicken, pork, and fish) cooked by a novel oil-free process and common with-oil processes were investigated. Oil-free cooking tends to emit lower total volatile organic compound (TVOC) levels and fewer submicron smoke particles and can reduce the intake of fat and calories. However, TVOC emissions during oil-free cooking were significantly different, and the lamb EFs were nearly 8 times higher than those during with-oil cooking. The particle-bound polycyclic aromatic hydrocarbon (ƩPPAH) and benzo(a)pyrene-equivalent (ƩBaPeq) EFs during with-oil cooking ranged from 76.1 to 140.5 ng/g and 7.7–12.4 ng/g, respectively, while those during oil-free cooking ranged from 41.0 to 176.6 ng/g and 5.4–47.6 ng/g, respectively. The ƩPPAH EFs of chicken, pork, and fish were lower during oil-free cooking than during cooking with oil. Furthermore, the ƩBaPeq EFs of beef, chicken, pork, and fish were lower during oil-free cooking than during cooking with oil. Therefore, it is recommended to use the oil-free method to cook chicken, pork, and fish to reduce ƩPPAH and ƩBaPeq emissions, but not recommended to cook lamb due to the increase of ƩBaPeq emissions. The with-oil uncovered cooking EFs of aldehydes ranged from 3.77 to 22.09 μg/g, and those of oil-free cooking ranged from 4.88 to 19.96 μg/g. The aldehyde EFs were lower during oil-free covered cooking than with-oil uncovered cooking for beef, chicken, and fish. This study provides a better realizing of new cooking approaches for the reduction of cooking-induced emission, but further research on the effects of food composition (moisture and fat) and characteristics is needed.

4 July 2023 in Environmental Pollution
Verified
Journal Article
Closed access
HWHo-Sheng Wei
Ho-Sheng Wei
ABAbiyu Kerebo Berekute
Abiyu Kerebo Berekute
SSSepridawati Siregar
Sepridawati Siregar
KYKuo-Pin Yu
Kuo-Pin Yu

7 January 2025 in Environmental Research
Verified
Journal Article
Closed access
ABAbiyu Kerebo Berekute
Abiyu Kerebo Berekute
AWAn-Yu Wang
An-Yu Wang
Kun-Yi (Andrew) LinKun-Yi (Andrew) Lin
Kun-Yi (Andrew) Lin
SSSepridawati Siregar
Sepridawati Siregar
KYKuo-Pin Yu
Kuo-Pin Yu

1 January 2025 in Indoor Air
Verified
Journal Article
Open access
MGMastewal Endeshaw Getnet
Mastewal Endeshaw Getnet
Wonder Nathi DlaminiWonder Nathi Dlamini
Wonder Nathi Dlamini
CLChun-Hsing Liao
Chun-Hsing Liao
ABAbiyu Kerebo Berekute
Abiyu Kerebo Berekute
ACAn-Fei Chen
An-Fei Chen
KYKuo-Pin Yu
Kuo-Pin Yu
Improving indoor air quality (IAQ) in hospital environments protects vulnerable patients and healthcare professionals from airborne pollutants and pathogens. This study integrates three interconnected components: a comprehensive analysis of hospital IAQ, an evaluation of a nanosilver/chitosan–titanium dioxide (nano‐Ag/CS‐TiO 2 ) filter, and an assessment of real‐time monitoring using a cloud‐based platform. The nano‐Ag/CS‐TiO 2 filter demonstrated enhanced efficiency in reducing a broad spectrum of pollutants, including particulate matter (PM 2.5 and PM 10 ), carbon monoxide, carbon dioxide, volatile organic compounds (VOCs), and microbial aerosols. Measurements were conducted across different hospital zones and timeframes to reflect typical hospital operations and assess the adaptability of the proposed solutions. The study further addresses the long‐term use of nano‐Ag/CS‐TiO 2 and underscores its advantages over existing filtration methods. Cloud‐based monitoring provides real‐time data, allowing for timely intervention for IAQ, particularly in high‐risk areas like negative pressure isolation rooms. The finding in a negative pressure isolation room demonstrated significant improvement in IAQ postinstallation of the nano‐Ag/CS‐TiO 2 filtration system. The integration of nano‐Ag/CS‐TiO 2 filtration and real‐time monitoring supports compliance with World Health Organization (WHO) IAQ standards. These findings highlight the potential for broader application in various healthcare settings, such as outpatient clinics and emergency departments. The study also ensures accuracy in pollutant detection, addressing the potential for false positives and negatives in cloud‐based monitoring. This study highlights that a nano‐Ag/CS‐TiO 2 filtration system can enhance IAQ in hospital settings by effectively removing air pollutants and inactivating airborne pathogens. This approach facilitates the development of evidence‐based strategies for promoting healthier indoor environments in hospitals.