Amy Chung

Amy Chung

Auto-generated profile, based on publicly available information

Amy Chung

Faculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2019 in Systematic Reviews
Verified
Journal Article
Open access
PDF file
ACAmy M. Chung
Amy M. Chung
MSMichael J. Stein
Michael J. Stein
AGAmmara Ghumman
Ammara Ghumman
JZJing Zhang
Jing Zhang
The widespread implementation of acellular dermal matrix (ADM) has broadened the reconstructive repertoire for alloplastic breast reconstruction. ADM’s role in the context of postoperative radiation therapy remains unclear. The present review will evaluate whether ADM reduces complication rates in patients undergoing post-mastectomy radiation therapy (PMRT). A healthcare librarian assisted in performing a search strategy of electronic databases MEDLINE (via Ovid), EMBASE, and CENTRAL. A combination of the keywords and Medical Subject Headings (MESH) to describe the various commercially available ADMs and terms for radiation therapy will be used. The search strategy will identify patients undergoing postoperative radiation following implant-based breast reconstruction and compare outcomes between those with and without ADM. Extracted data will include patient demographics, intraoperative data, and postoperative complications. Data on patient satisfaction and resource utilization will also be extracted if available. The references of selected works will be reviewed for additional studies meeting study criteria. Only peer-reviewed papers written in English will be included. The study data will be assessed for risk of bias and heterogeneity. Providing that sufficient studies can be identified, a meta-analysis will be performed. This review has been registered with PROSPERO (CRD42017056495). To date, the short- and long-term performance of ADM in the context of postoperative radiation remains unclear. The objective of the present review will be to critically evaluate the literature with the intention of improving postoperative outcomes in the context of mastectomy and radiation.

20 May 2015 in Polish Heart Journal
Verified
Journal Article
Open access
JSJerzy Sadowski
Jerzy Sadowski
KBKrzysztof Bartuś
Krzysztof Bartuś
BKBogusław Kapelak
Bogusław Kapelak
ACAmy Chung
Amy Chung
MSMaciej Stąpor
Maciej Stąpor
MBMaciej Bochenek
Maciej Bochenek
The primary cause of long-term failure of bioprosthetic valves is structural valve deterioration due to tissue calcification. A novel anti-calcification technology platform was developed that may irreversibly block calcium binding sites in bioprosthetic valves. Twenty patients with severe aortic stenosis underwent isolated aortic valve replacement using a bioprosthetic valve treated with the novel anti-calcification technology. Mean patient age and body mass index was 73.7 ± 4.8 years and 30.1 ± 5.8 kg/m², respectively. Females comprised 65% of the patient population, and 30% of the population was in New York Heart Association class III/IV. Other baseline characteristics included hypertension (90%), hyperlipidaemia (75%), diabetes (35%), renal failure (25%), pulmonary disease (10%), and myocardial infarction (10%). Patients were followed-up for up to one year. Haemodynamic performance was evaluated by echocardiography. All complications were recorded. There was one early death on postoperative day five. No other complications were noted up to discharge. Follow-up at 3-6 months and at one year were both 100%. At one year, no valve-related mortality, structural valve deterioration, major paravalvular leak (> 2+), thromboembolic events, major bleeding, prosthetic valve endocarditis, or reoperation were observed. Mean effective orifice area increased from 1.0 ± 0.5 cm² at baseline to 1.8 ± 0.5 cm² at one year. Mean gradient decreased from 54.8 ± 21.2 mm Hg at baseline to 11.3 ± 3.4 mm Hg at one year. This early clinical experience using an aortic bioprosthetic valve treated with a novel anti-calcification tissue processing technology demonstrated excellent valve performance, durability, and safety. No valve-related complications were noted. Longer-term follow-up is needed to verify these promising results.

1 December 2020 in Journal of Plastic, Reconstructive & Aesthetic Surgery
Verified
Journal Article
Closed access
MSMichael J. Stein
Michael J. Stein
ACAmy Chung
Amy Chung
AAAngel Arnaout
Angel Arnaout
BGBahareh Ghaedi
Bahareh Ghaedi
AGAmmara Ghumman
Ammara Ghumman
JZJing Zhang
Jing Zhang