Debra E. Kollonige

Debra E. Kollonige

Auto-generated profile, based on publicly available information

Debra E. Kollonige

NASA Goddard Space Flight Center

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2021 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
PDF file
ATAnne M. Thompson
Anne M. Thompson
RSRyan Stauffer
Ryan Stauffer
KWKrzysztof Wargan
Krzysztof Wargan
JWJacquelyn C. Witte
Jacquelyn C. Witte
DKDebra E. Kollonige
Debra E. Kollonige
JZJerald R. Ziemke
Jerald R. Ziemke
Understanding lowermost stratosphere (LMS) ozone variability is an important topic in the trends and climate assessment communities because of feedbacks among changing temperature, dynamics, and ozone. LMS evaluations are usually based on satellite observations. Free tropospheric (FT) ozone assessments typically rely on profiles from commercial aircraft. Ozonesonde measurements constitute an independent data set encompassing both LMS and FT. We used Southern Hemisphere Additional Ozonesondes (SHADOZ) data (5.8°N–14°S) from 1998 to 2019 in the Goddard Multiple Linear Regression model to analyze monthly mean FT and LMS ozone changes across five well‐distributed tropical sites. Our findings: (a) both FT (5–15 km) and LMS (15–20 km) ozone trends show marked seasonal variability. (b) All stations exhibit FT ozone increases in February‐May (up to 15%/decade) when the frequency of convectively driven waves have changed. (c) After May, monthly ozone changes are both positive and negative, leading to mean trends of +(1–4)%/decade, depending on station. (d) LMS ozone losses reach (4–9)%/decade midyear, correlating with an increase in TH as derived from SHADOZ radiosonde data. (e) When the upper FT and LMS are defined by tropopause‐relative coordinates, the LMS ozone trends all become insignificant. Thus, the 20‐year decline in tropical LMS ozone reported in recent satellite‐based studies likely signifies a perturbed tropopause rather than chemical depletion. The SHADOZ‐derived ozone changes highlight regional and seasonal variability across the tropics and define a new reference for evaluating changes derived from models and satellite products over the 1998–2019 period.

21 October 2022 in Earth and Space Science
Verified
Journal Article
Open access
RSRyan Stauffer
Ryan Stauffer
ATAnne M. Thompson
Anne M. Thompson
DKDebra E. Kollonige
Debra E. Kollonige
DTDavid W. Tarasick
David W. Tarasick
RMRoeland Van Malderen
Roeland Van Malderen
MYMichael M. Yan
Michael M. Yan
The recent Assessment of Standard Operating Procedures for Ozonesondes 2.0 (WMO/GAW Report #268) addressed questions of homogeneity and long‐term stability in global electrochemical concentration cell (ECC) ozone sounding network time series. Among its recommendations was adoption of a standard for evaluating data quality in ozonesonde time series. Total column ozone (TCO) derived from the sondes compared to TCO from Aura's Ozone Monitoring Instrument (OMI) is a primary quality indicator. Comparisons of sonde ozone with Aura's Microwave Limb Sounder (MLS) are used to assess the stability of stratospheric ozone. This paper provides a comprehensive examination of global ozonesonde network data stability and accuracy since 2004 in light of the sudden post‐2013 TCO “dropoff” of ∼3%–4% that was reported previously at select stations (Stauffer et al., 2020, https://doi.org/10.1029/2019GL086791). Comparisons with Aura OMI TCO averaged across the network of 60 stations are stable within about ±2% over the past 18 years. Sonde TCO has similar stability compared to three other TCO satellite instruments, and the stratospheric ozone measurements average to within ±5% of MLS from 50 to 10 hPa. Thus, sonde data are reliable for trends, but with a caveat applied for a subset of dropoff stations in the tropics and subtropics. The dropoff is associated with only one of two major ECC instrument types. A detailed examination of ECC serial numbers pinpoints the timing of the dropoff. However, we find that overall, ozonesonde data are stable and accurate compared to independent measurements over the past two decades.

4 June 2020 in Geophysical Research Letters
Verified
Journal Article
Open access
PDF file
RSRyan Stauffer
Ryan Stauffer
ATAnne M. Thompson
Anne M. Thompson
DKDebra E. Kollonige
Debra E. Kollonige
JWJacquelyn C. Witte
Jacquelyn C. Witte
DTDavid Tarasick
David Tarasick
HSHerman G. J. Smit
Herman G. J. Smit
An international effort to improve ozonesonde data quality and to reevaluate historical records has made significant improvements in the accuracy of global network data. However, between 2014 and 2016, ozonesonde total column ozone (TCO; O3) at 14 of 37 regularly reporting stations exhibited a sudden dropoff relative to satellite measurements. The ozonesonde TCO drop is 3–7% compared to satellite and ground‐based TCO, and 5–10% or more compared to satellite stratospheric O3 profiles, compromising the use of recent data for trends, although they remain reliable for other uses. Hardware changes in the ozonesonde instrument are likely a major factor in the O3 dropoff, but no single property of the ozonesonde explains the findings. The bias remains in recent data. Research to understand the dropoff is in progress; this letter is intended as a caution to users of the data. Our findings underscore the importance of regular ozonesonde data evaluation.

12 November 2019 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
PDF file
ATAnne M. Thompson
Anne M. Thompson
RSRyan Stauffer
Ryan Stauffer
TBTyler P. Boyle
Tyler P. Boyle
DKDebra E. Kollonige
Debra E. Kollonige
KMKazuyuki Miyazaki
Kazuyuki Miyazaki
BLBrian T. Lamb
Brian T. Lamb
Near‐surface air quality (AQ) observations over coastal waters are scarce, a situation that limits our capacity to monitor pollution events at land‐water interfaces. Satellite measurements of total column (TC) nitrogen dioxide (NO2) observations are a useful proxy for combustion sources, but the once daily snapshots available from most sensors are insufficient for tracking the diurnal evolution and transport of pollution. Ground‐based remote sensors like the Pandora Spectrometer Instrument (PSI) that have been developed to verify space‐based TC NO2 and other trace gases are being tested for routine use as certified AQ monitors. The KORUS‐OC (Korea‐United States Ocean Color) cruise aboard the R/V Onnuri in May–June 2016 represented an opportunity to study AQ near the South Korean coast, a region affected by both local/regional and long‐distance pollution sources. Using PSI data in direct‐Sun mode and in situ sensors for shipboard ozone, CO, and NO2, we explore, for the first time, relationships between TC NO2 and surface AQ in this coastal region. Three case studies illustrate the value of the PSI and complexities in the surface‐column NO2 relationship caused by varying meteorological conditions. Case Study 1 (25–26 May 2016) exhibited a high correlation of surface NO2 to TC NO2 measured by both PSI and Aura's Ozone Monitoring Instrument, but two other cases displayed poor relationships between in situ and TC NO2 due to decoupling of pollution layers from the surface. With suitable interpretation the PSI TC NO2 measurement demonstrates good potential for working with upcoming geostationary satellites to advance diurnal tracking of pollution.

27 January 2018 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Closed access
PDF file
DKDebra E. Kollonige
Debra E. Kollonige
ATAnne M. Thompson
Anne M. Thompson
MJMiroslav Josipovic
Miroslav Josipovic
MTMaria Tzortziou
Maria Tzortziou
PBPaul Johan Beukes
Paul Johan Beukes
LLLauri Laakso
Lauri Laakso

10 June 2022 in ESS Open Archive
Verified
Preprint
Open access
RSRyan Stauffer
Ryan Stauffer
ATAnne M. Thompson
Anne M. Thompson
DKDebra Kollonige
Debra Kollonige
DTDavid Tarasick
David Tarasick
RMRoeland Van Malderen
Roeland Van Malderen
MYMichael M Yan
Michael M Yan
The recent Assessment of Standard Operating Procedures for OzoneSondes (ASOPOS 2.0; WMO/GAW Report #268) addressed questions of homogeneity and long-term stability in global electrochemical concentration cell (ECC) ozone sounding network time series. Among its recommendations was adoption of a standard for evaluating data quality in ozonesonde time-series. Total column ozone (TCO) derived from the sondes compared to TCO from Aura’s Ozone Monitoring Instrument (OMI) is a primary quality indicator. Comparisons of sonde ozone with Aura’s Microwave Limb Sounder (MLS) are used to assess the stability of stratospheric ozone. This paper provides a comprehensive examination of global ozonesonde network data stability and accuracy since 2004. Comparisons with Aura OMI TCO averaged across the network of 60 stations are stable within about +/-2% over the past 18 years. Sonde TCO has similar stability compared to three other TCO satellite instruments, and the stratospheric ozone measurements average to within +/-5% of MLS from 50 to 10 hPa. Thus, sonde data are reliable for trends, but with a caveat applied for a subset of stations in the tropics and subtropics for which a sudden post-2013 TCO “dropoff” of ~3-4% was reported previously (Stauffer et al., 2020). The dropoff is associated with only one of two major ECC instrument types. A detailed examination of ECC serial numbers pinpoints the timing of the dropoff. However, we find that overall, ozonesonde data are stable and accurate compared to independent measurements over the past two decades.