Nuri Saraç

Nuri Saraç

Auto-generated profile, based on publicly available information

Nuri Saraç


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
SDSelin Ardali Duzgun
Selin Ardali Duzgun
İTİlke Taşçı
İlke Taşçı
ATAtahan Tamtürk
Atahan Tamtürk
NSNuri Saraç
Nuri Saraç
MKMelih Karadağ
Melih Karadağ
GDGamze Durhan
Gamze Durhan
Background/Objectives: Artificial intelligence (AI) increasingly supports chest radiograph interpretation, but per-abnormality comparisons of commercial tools using CT-anchored reference standards remain limited. We compared two commercial AI tools using a CT-anchored, CXR-targeted reference framework. Methods: We retrospectively reviewed chest radiographs obtained between 30 October 2023 and 10 October 2024. Each radiograph was paired with CT performed within 14 days or within 2 days for rapidly progressive findings. Seven abnormalities across five analysis categories were evaluated: fracture, nodule, pleural effusion, pneumothorax, and airspace disease (edema, atelectasis, opacity/consolidation). Radiologists first confirmed abnormalities on CT then assessed their visibility on the paired radiograph. Outputs from vendors A and B were recorded. Sensitivity was calculated for CT-confirmed, radiographically visible abnormalities; specificity, precision, and accuracy were calculated within the same detectability framework. Vendors were compared using McNemar’s test. Results: The cohort included 1707 radiographs from 1680 patients (mean age, 60.3 ± 16.5 years; 50.5% male). Of 3573 CT-confirmed abnormalities, 1981 (55.4%) were radiographically visible and formed the primary reference-positive set. Vendor A had higher sensitivity for fractures, nodules, and pleural effusions (all p < 0.001), whereas vendor B had higher specificity for these findings (all p < 0.05). For pneumothorax, vendor B showed numerically higher sensitivity but lower specificity and accuracy; case numbers were limited, and precision was low for both tools. No significant differences were observed for harmonized airspace disease. Overall specificity was high, while sensitivity and precision varied across abnormalities. Conclusions: Both tools showed abnormality-specific strengths and limitations, supporting tailored implementation and real-world clinical validation.

1 March 2022 in Journal of Ankara University Faculty of Medicine
Verified
Journal Article
Closed access
SDSerhat Dinç
Serhat Dinç
OKOsman Nuri Kılıç
Osman Nuri Kılıç
EKEzgisu Kırnap
Ezgisu Kırnap
İMİpek Mavcioğlu
İpek Mavcioğlu
NSNuri Saraç
Nuri Saraç
AGAslıhan Gürbüz
Aslıhan Gürbüz