VersaCross is a novel radiofrequency transseptal solution that may improve the efficiency and workflow of transseptal puncture (TSP). The aim of this study was to compare the VersaCross transseptal system with mechanical needle systems during mitral transcatheter edge-to-edge repair (M-TEER) with the PASCAL device. This is a single-center retrospective study of consecutive patients who underwent M-TEER with the PASCAL. Transseptal puncture was undertaken with either a mechanical needle or the VersaCross wire. The primary endpoints were success of TSP and successful delivery of the Edwards sheath on the chosen delivery wire. Secondary endpoints included number of wires used, tamponade rate, interval from femoral venous access to TSP and first PASCAL device deployment, procedural death, and stroke. Thirty-three consecutive patients (10 with mechanical needle, 23 with VersaCross) who underwent M-TEER with the Edwards PASCAL device were identified. All patients had successful TSP. In the mechanical needle group, the Edwards sheath was successfully delivered on the Superstiff Amplatz wire in all cases. In the VersaCross arm, the radiofrequency wire was used successfully for delivery of the sheath in all cases. There were no cases of pericardial effusion/tamponade in either arm. Interval from femoral venous access to TSP and to deployment of the first PASCAL device was shorter with the VersaCross system. Significantly fewer wires were used with VersaCross. There were no procedural deaths or strokes in either group. VersaCross appears a safe and effective method of TSP and for delivery of the 22Fr sheath for M-TEER with PASCAL.
Treating acute myocardial infarction in the setting of insignificant coronary obstruction is an emerging challenge especially with the application of intracoronary imaging like intravascular ultrasound and optical coherence tomography (OCT). The cardiologists dealing with such patients may consider not to stent if there is intracoronary imaging evidence of minimal thrombus without plaque rupture and the vessel appears patent with settling of chest pain and electrocardiogram (ECG) changes. A 47-year-old gentleman presented direct to the emergency department after experiencing retrosternal chest pain with an ECG showing hyperacute anterior T waves. He had ongoing chest pain and was therefore brought to the cardiac cath lab on the primary percutaneous coronary intervention (PCI) pathway. The first picture showed that the proximal left anterior descending (LAD) was occluded (TIMI 0 flow) with evidence of large thrombus burden. Pre-dilating with a 2.5 × 15 mm balloon did not change flow. Aspiration with an Export catheter was carried out for several runs. Most of the thrombus was successfully removed; however, some of it did go into the distal LAD but was successfully retrieved with aspiration catheter. The diagonal branch was occluded with thrombus which was wired followed by thrombus aspiration establishing TIMI II flow. The procedure was covered with Eptifibatide boluses and heparin. After thrombectomy, angiographically there was no obvious lesion present within the LAD. Optical coherence tomography confirmed only mild atheroma with a small amount of plaque and minimal thrombus. There was OCT evidence of plaque erosion without any plaque rupture. The area was above 9 mm2 and we decided not to treat that with a stent. The right coronary artery had an anterior take-off and was unobstructed. In conclusion, the patient had successful primary PCI to LAD with thrombus aspiration and balloon angioplasty only. He was placed on 12 months of dual antiplatelets therapy with Aspirin and Prasugrel. This case highlights the rare presentation of patients with acute myocardial infarction with plaque erosion and the usefulness of OCT in formulating a management plan.