Kyoung Min Yoo

Kyoung Min Yoo

Auto-generated profile, based on publicly available information

Kyoung Min Yoo

Department of Electrical and Computer Engineering, The University of Texas at Austinhttps://ror.org/00hj54h04, 10100 Burnet Rd., Austin, Texas 78758, USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2021 in Applied Physics Reviews
Verified
Journal Article
Open access
PDF file
AAAref Asghari
Aref Asghari
CWChao Wang
Chao Wang
KYKyoung Min Yoo
Kyoung Min Yoo
ARAli Rostamian
Ali Rostamian
XXXiaochuan Xu
Xiaochuan Xu
RCRay Chen
Ray Chen
The sudden rise of the worldwide severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic in early 2020 has called into drastic action measures to perform instant detection and reduce the rate of spread. Common clinical and nonclinical diagnostic testing methods have been partially effective in satisfying the increasing demand for fast detection point-of-care (POC) methods to slow down further spread. However, accurate point-of-risk diagnosis of this emerging viral infection is paramount as the need for simultaneous standard operating procedures and symptom management of SARS-CoV-2 will be the norm for years to come. A sensitive, cost-effective biosensor with mass production capability is crucial until a universal vaccination becomes available. Optical biosensors can provide a noninvasive, extremely sensitive rapid detection platform with sensitivity down to ∼67 fg/ml (1 fM) concentration in a few minutes. These biosensors can be manufactured on a mass scale (millions) to detect the COVID-19 viral load in nasal, saliva, urine, and serological samples, even if the infected person is asymptotic. Methods investigated here are the most advanced available platforms for biosensing optical devices that have resulted from the integration of state-of-the-art designs and materials. These approaches include, but are not limited to, integrated optical devices, plasmonic resonance, and emerging nanomaterial biosensors. The lab-on-chip platforms examined here are suitable not only for SARS-CoV-2 spike protein detection but also for other contagious virions such as influenza and Middle East respiratory syndrome (MERS).

4 March 2020 in ACS Sensors
Verified
Journal Article
Closed access
KYKyoung Min Yoo
Kyoung Min Yoo
JMJason Midkiff
Jason Midkiff
ARAli Rostamian
Ali Rostamian
CCChi-Jui Chung
Chi-Jui Chung
HDHamed Dalir
Hamed Dalir
RCRay T. Chen
Ray T. Chen

3 November 2020 in Optica
Verified
Journal Article
Closed access
PDF file
JMJason Midkiff
Jason Midkiff
KYKyoung Min Yoo
Kyoung Min Yoo
JSJong-Dug Shin
Jong-Dug Shin
HDHamed Dalir
Hamed Dalir
MTMohammad Teimourpour
Mohammad Teimourpour
RCRay Chen
Ray Chen
Compact, lightweight, high-power beam-steering devices operating in the mid-infrared atmospheric window λ = 3 − 5 µ m are attractive for aerial-based applications such as long-range lidar and countermeasures. In the near-infrared spectral region, optical phased arrays (OPAs) have emerged as the dominant nonmechanical on-chip beam-steering technology, with a preponderance in silicon-based platforms. Extensions to the mid-infrared spectral region are scarce. Further, considering that the requirements for high performance in this region will likely demand monolithic integration with quantum cascade lasers, development of the photonic technology on a native III–V platform is advantageous. To this end, at λ = 4.6 µ m , on an InGaAs/InP platform, we experimentally demonstrate the operation of a 32-channel OPA with thermo-optic tuning for azimuthal (lateral) steering. With a waveguide spacing of 2.5 λ , we steer the beam to the maximum uninfringed field of view at ± 11.5 ∘ .

10 October 2023 in Optics Letters
Verified
Journal Article
Closed access
PDF file
KYKyoung Min Yoo
Kyoung Min Yoo
KFKang-Chieh Fan
Kang-Chieh Fan
MHMay Hlaing
May Hlaing
SJSourabh Jain
Sourabh Jain
SNShupeng Ning
Shupeng Ning
RCRay Chen
Ray Chen
In this paper, we demonstrated the design and experimental results of the near-infrared lab-on-a-chip optical biosensor platform that monolithically integrates the MRR and the on-chip spectrometer on the silicon-on-insulator (SOI) wafer, which can eliminate the external optical spectrum analyzer for scanning the wavelength spectrum. The symmetric add-drop MRR biosensor is designed to have a free spectral range (FSR) of ∼19 nm and a bulk sensitivity of ∼73 nm/RIU; then the drop-port output resonance peaks are reconstructed from the integrated spatial-heterodyne Fourier transform spectrometer (SHFTS) with the spectral resolution of ∼3.1 nm and the bandwidth of ∼50 nm, which results in the limit of detection of 0.042 RIU.

21 July 2022 in ACS Photonics
Verified
Journal Article
Open access
KYKyoung Min Yoo
Kyoung Min Yoo
RCRay Chen
Ray Chen
On-chip broadband optical spectrometers that cover the entire tissue transparency window (λ = 650-1050 nm) with high resolution are highly demanded for miniaturized biosensing and bioimaging applications. The standard spatial heterodyne Fourier transform spectrometer (SHFTS) requires a large number of Mach-Zehnder interferometer (MZI) arrays to obtain a broad spectral bandwidth while maintaining high resolution. Here, we propose a novel type of SHFTS integrated with a subwavelength grating coupler (SWGC) for the dual-polarization bandpass sampling on the Si3N4 platform to solve the intrinsic trade-off limitation between the bandwidth and resolution of the SHFTS without having an outrageous number of MZI arrays or adding additional active photonic components. By applying the bandpass sampling theorem, the continuous broadband input spectrum is divided into multiple narrow-band channels through tuning the phase-matching condition of the SWGC with different polarization and coupling angles. Thereby, it is able to reconstruct each band separately far beyond the Nyquist criterion without aliasing error or degrading the resolution. We experimentally demonstrated the broadband spectrum retrieval results with the overall bandwidth coverage of 400 nm, bridging the wavelengths from 650 to 1050 nm, with a resolution of 2-5 nm. The bandpass sampling SHFTS is designed to have 32 linearly unbalanced MZIs with the maximum optical path length difference of 93 μm within an overall footprint size of 4.7 mm × 0.65 mm, and the coupling angles of SWGC are varied from 0° to 32° to cover the entire tissue transparency window.

1 January 2019 in AIP Advances
Verified
Journal Article
Open access
PDF file
CCChi-Jui Chung
Chi-Jui Chung
JMJason Midkiff
Jason Midkiff
KYKyoung Min Yoo
Kyoung Min Yoo
ARAli Rostamian
Ali Rostamian
JGJoel Guo
Joel Guo
SCSwapnajit Chakravarty
Swapnajit Chakravarty
We design and experimentally demonstrate the propagation loss of waveguides and the operation of a single-step etched polarization rotator-splitter (PRS) in low index contrast InGaAs-InP material system at 6.15 μm. Propagation losses 4.19 dB/cm for TM mode and 3.25 dB/cm for TE mode are measured. The designed PRS can achieve near 100% conversion efficiency. This study enables the possibility of monolithic integration of quantum cascade devices with TM-polarized characteristics and TE-guiding two-dimensional slotted photonic crystal waveguide gas sensors for on-chip monolithic absorption spectroscopy.