15 May 2023 in Applied Physics Letters
A 400 MHz magnetoelectric (ME) Lamb wave antenna design to function in the medical implant communication service band is proposed. The antenna employs a heterostructure of piezoelectric and magnetostrictive membranes to acoustically excite standing shear bulk wave and radiate as a magnetic dipole. Multiphysics finite element analysis simulations are performed for transmission and reception modes. In these simulations, three aspects are investigated: piezoelectricity, micromagnetic precession, and magnetic dipole radiation. An experimental demonstration of the antenna is also conducted and shows mechanical resonance with a Q-factor of 500 and ME coupling. These results indicate that the design can be operated in zero-order antisymmetric (A0) mode as a tunable oscillator or sensor. This ME approach provides a solution to the miniaturization problem of traditional current-based implantable antennas.
1 January 2015 in Journal of Clinical Medicine Research
AMAlbert Alexander Valencia Moreno
Albert Alexander Valencia Moreno
JGJose A. Rojas Gambasica
YBYamil E. Jaller Bornacelli
Yamil E. Jaller Bornacelli
Idiopathic peripartum cardiomyopathy presenting with heart failure is a true diagnostic and treatment challenge. Goal oriented clinical management aims at the relapse of left ventricular systolic dysfunction. A 35-year-old patient on her 12th day post-delivery presents progressive signs of heart failure. Transthoracic echocardiography showed severe mitral insufficiency, mild left ventricular dysfunction, mild tricuspid insufficiency, severe pulmonary hypertension, and right atrial enlargement. With wet and cold heart failure signs, the patient was a candidate for inodilator cardiovascular support and volume depletion therapy. As the patient presented a persistent tachycardia at rest, levosimendan was chosen over dobutamine. Levosimendan was administered at a dose of 0.2 µg/kg/min during a period of 24 hours. After inodilator therapy, the patient’s signs and symptoms of heart failure began to decrease, showing improvement of dyspnea, mitral murmur grade went from IV/IV to II/IV, filling pressures and systemic and pulmonary resistance indexes decreased, arterial blood gases improved, and an echocardiography performed 72 h later showed non-dilated cardiomyopathy, mild cardiac contractile dysfunction, mild mitral insufficiency, type I diastolic dysfunction and improvement of pulmonary hypertension. Cardiovascular function in peripartum cardiomyopathy tends to go back to normality in 23-41% of the cases, but in a large group of patients, severe ventricle dysfunction remains months after initial symptoms. This article describes the diagnostic process of a patient with peripartum cardiomyopathy and a successful reversion of a severe case of mitral insufficiency using levosimendan as a new therapeutic strategy in this clinical context. J Clin Med Res. 2015;7(12):998-1001 doi: http://dx.doi.org/10.14740/jocmr2323
10 April 2024 in Nanoscale
Tuning the magnetoelectric behavior of epitaxial 15 nm-thick Fe–Ga microstructures by varying their shape, size and orientation.
28 November 2025 in Journal of Materials Research