Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2023 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
RZRuoda Zheng
Ruoda Zheng
VEVictor Estrada
Victor Estrada
NVNishanth Virushabadoss
Nishanth Virushabadoss
AWAlexandria Will-Cole
Alexandria Will-Cole
AAAdrian Acosta
Adrian Acosta
ASAbdon E Sepulveda
Abdon E Sepulveda
A 400 MHz magnetoelectric (ME) Lamb wave antenna design to function in the medical implant communication service band is proposed. The antenna employs a heterostructure of piezoelectric and magnetostrictive membranes to acoustically excite standing shear bulk wave and radiate as a magnetic dipole. Multiphysics finite element analysis simulations are performed for transmission and reception modes. In these simulations, three aspects are investigated: piezoelectricity, micromagnetic precession, and magnetic dipole radiation. An experimental demonstration of the antenna is also conducted and shows mechanical resonance with a Q-factor of 500 and ME coupling. These results indicate that the design can be operated in zero-order antisymmetric (A0) mode as a tunable oscillator or sensor. This ME approach provides a solution to the miniaturization problem of traditional current-based implantable antennas.

1 January 2015 in Journal of Clinical Medicine Research
Verified
Journal Article
Open access
PDF file
VEVictor H. Nieto Estrada
Victor H. Nieto Estrada
DMDANIEL MOLANO
DANIEL MOLANO
AMAlbert Alexander Valencia Moreno
Albert Alexander Valencia Moreno
JGJose A. Rojas Gambasica
Jose A. Rojas Gambasica
YBYamil E. Jaller Bornacelli
Yamil E. Jaller Bornacelli
AVAnacaona Martinez Del Valle
Anacaona Martinez Del Valle
Idiopathic peripartum cardiomyopathy presenting with heart failure is a true diagnostic and treatment challenge. Goal oriented clinical management aims at the relapse of left ventricular systolic dysfunction. A 35-year-old patient on her 12th day post-delivery presents progressive signs of heart failure. Transthoracic echocardiography showed severe mitral insufficiency, mild left ventricular dysfunction, mild tricuspid insufficiency, severe pulmonary hypertension, and right atrial enlargement. With wet and cold heart failure signs, the patient was a candidate for inodilator cardiovascular support and volume depletion therapy. As the patient presented a persistent tachycardia at rest, levosimendan was chosen over dobutamine. Levosimendan was administered at a dose of 0.2 µg/kg/min during a period of 24 hours. After inodilator therapy, the patient’s signs and symptoms of heart failure began to decrease, showing improvement of dyspnea, mitral murmur grade went from IV/IV to II/IV, filling pressures and systemic and pulmonary resistance indexes decreased, arterial blood gases improved, and an echocardiography performed 72 h later showed non-dilated cardiomyopathy, mild cardiac contractile dysfunction, mild mitral insufficiency, type I diastolic dysfunction and improvement of pulmonary hypertension. Cardiovascular function in peripartum cardiomyopathy tends to go back to normality in 23-41% of the cases, but in a large group of patients, severe ventricle dysfunction remains months after initial symptoms. This article describes the diagnostic process of a patient with peripartum cardiomyopathy and a successful reversion of a severe case of mitral insufficiency using levosimendan as a new therapeutic strategy in this clinical context. J Clin Med Res. 2015;7(12):998-1001 doi: http://dx.doi.org/10.14740/jocmr2323

10 April 2024 in Nanoscale
Verified
Journal Article
Open access
PDF file
MGMaite Goiriena
Maite Goiriena
ZXZhuyun Xiao
Zhuyun Xiao
RSRachel Steinhardt
Rachel Steinhardt
VEVictor Estrada
Victor Estrada
NTNobumichi Tamura
Nobumichi Tamura
JBJeffrey Bokor
Jeffrey Bokor
Tuning the magnetoelectric behavior of epitaxial 15 nm-thick Fe–Ga microstructures by varying their shape, size and orientation.

28 November 2025 in Journal of Materials Research
Verified
Journal Article
Closed access
PDF file
VEVictor Estrada
Victor Estrada
RZRuoda Zheng
Ruoda Zheng
YWYilian Wang
Yilian Wang
HMHiromi Miwa
Hiromi Miwa
MBMichael Bogumil
Michael Bogumil
ASAbdon Sepulveda
Abdon Sepulveda