1 September 2021 in Polymer Composites
6 December 2023 in KSCE Journal of Civil Engineering
This paper investigated the seismic performance of a typical “Integrated Station-Bridge high-speed railway station structure with a composite isolation system. The influential mechanism of the structure with isolation system was analyzed based on shaking table tests, mainly investigating on the failure mode, acceleration response and displacement response. Besides, a parameter optimization method of isolation layer for long-span structures was proposed based on genetic algorithm to better enhance the isolation performance of the large-span structure. The research revealed that there was no obvious damage to the composite isolation system under the PGA = 0.82 g. The nature frequency of the structure with isolation system is only 12.5% of that of non-isolation structure. The first three natural vibration frequency of the structure with isolation system only reduce 3.4%, 3.2%, 6.14% after the PGA = 1.27 g, that of the non-isolation structure reduce by more than 20%. The acceleration amplification factor of each layer of composite isolation system is less than 1, in particular, that of truss is about 0.3. The displacement response and acceleration response of the structure with isolation system have been reduced by about 90%. The proposed optimization method of isolation layer parameters provides an important reference for the isolation design for high-speed railway stations.
1 May 2025 in Journal of Industrial Textiles
Weld seam connection is a common form of connection for the main stress joints in membrane structures. However, current research overlooks the impact of off-axis angles of coated fabric on stress distribution. To thoroughly understand the welding connection performance and tensile failure mechanisms, this paper investigated the tensile properties of PVC-coated fabrics with single-layer off-axis patch and double-layer off-axis patch. The effects of off-axial angle, overlapping connection method, and weld width on tensile strength and elongation at break were examined. The results indicate that, as the off-axis angle varies, the tensile strength and elongation at break of the coated fabric welding-covered connection specimens display two distinct trends. According to Digital image correlation (DIC) testing, warp patch coverage is beneficial for the coordinated stress and reasonable distribution of strain field in the coated fabric. In the design of PVC-coated fabric connection with weld seam cover treatment, it is necessary to consider the strength reduction at the welding site based on the connection type, weld width, and off-axis angle. Double-layer connections with patch widths exceeding 70 mm are recommended when the substrate material and patch are in warp-weft orientation; For off-axis designs, a 45° material offset angle may be adopted with patch widths greater than 50 mm.
1 October 2020 in Structures