10 August 2021 in IEEE Transactions on Power Delivery
This paper proposes a novel pilot protection scheme for LCC-HVDC transmission lines based on the measured surge impedance at tuning frequency. On the basis of amplitude-frequency characteristic of DC filter, it is found that the voltage forward traveling wave and reverse traveling wave at tuning frequency approximately satisfy total reflection at the line boundary after the internal fault. Then, combined with the traveling wave propagating processes for DC line internal faults and external faults, it is found that for internal faults, for two terminals of line, measured surge impedances at tuning frequency are both close to 0 Ω, whereas for external faults, the measured surge impedance at tuning frequency near faulty terminal equals line surge impedance, whose value is generally about 200∼300 Ω, and another value at the distance faulty terminal is close to 0 Ω. Thus, this difference is utilized for fault identification. Comprehensive simulations demonstrate that the proposed protection scheme has the ability to identify DC line internal and external faults accurately. Meanwhile, the protection scheme has no requirement for two-terminal data synchronization and has low communication requirement. Besides, it can respond to the high-resistance faults sensitively.
27 March 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
On 9 August 2019, a blackout event with significant impacts occurred in the British power grid (BPG). The technical report submitted by the BPG points out that the accident originated from multiple independent and concurrent events, resulting in a sudden power shortage, which exceeded the fortification requirements of the relevant standards. This incident has led us to reflect on some of the technical bottlenecks that exist in the high-proportion renewable energy system, such as frequency oscillations, security defense of large power grid, current-limiting and so on. Based on this background, this paper studies a strong current-limiting control system suitable for ground faults in AC microgrid, which can limit the fault current to less than twice the rated current so that the distributed generators can go through multiple faults ride-through without offline operation. Meanwhile, this control system does not need to switch the reference inductance current between normal and faults, and can realize the smaller current harmonics and lower asymmetry amplitudes in the two states. Simulation and experiment show that the method proposed in this paper can adapt to a variety of ground faults.
31 July 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
With the occurrence of the major blackouts in “Australia 9·28” and the “U.K. 8·9,” the technical bottlenecks in the power generation system with a high proportion of renewable energy have attracted more and more attention. Based on this background, this article studies a control method that is suitable for AC microgrid with strong current-limiting ability. First, the outer loop controller adopts the method of power-state equation based on PI control to achieve accurate tracking of the reference power. Furthermore, in order to make the fault current having a lower asymmetry degree and smaller amplitude, the outer loop controller only considers the positive-sequence components of the voltage and adds twice rated current limiter. Second, the inner loop controller adopts an improved Lyapunov-function method with antiparametric disturbance ability to track the reference inductance current. By selecting the optimal controller gains, the current harmonics and amplitudes can meet the desired requirements. Finally, the simulation builds a microgrid with four distributed generators (DGs) in MATLAB/Simulink and tests the effectiveness of the proposed current-limiting method.
28 March 2023 in IEEE Transactions on Power Delivery
This article proposes an innovative DC line protection utilizing current correlation coefficient for hybrid cascaded high-voltage direct-current (HVDC) system. First, the equivalent discharge circuit after DC line fault is inferred, and then fault characteristic analysis on the superimposed network reveals that for the transmission lines connecting line commutated converter (LCC) and modular multilevel converters (MMCs), high-frequency currents of faulty line and non-fault line are negatively correlated, their correlation coefficient is theoretically -1. Whereas, high-frequency currents of two non-fault lines show a strong positive correlation, their correlation coefficient equals theoretically 1. Then, cosine correlation coefficient is adopted to describe current correlations and construct the identification criterion. Simulation demonstrates that protection could differentiate the faulty line accurately. Additionally, it has high sensitivity for high-resistance fault. And it is simple and has low computational complexity, and is insensitive to the line boundary element.
19 June 2025 in IEEE Transactions on Smart Grid
The integration of power electronic devices and distributed energy resources (DERs) into distribution networks is crucial for enhancing service restoration performance through flexible power regulation. However, the complex operational requirements pose challenges in coordinating them during power outages. To leverage the potential application value of multiple resources, this paper proposes a distributed robust restoration strategy that incorporates iterative and accelerated techniques. A soft open point integrated with energy storage is introduced and optimized alongside the local DERs. The distributionally robust optimization (DRO) method is used during the implementation of the recovery strategy, facilitating the participation of intermittent renewable sources. These measures collectively enhance system resilience. Subsequently, a distributed robust service restoration framework based on the alternating direction method of multipliers (ADMM) is employed for multiregional networks, allowing the robust model to be solved in a distributed manner. To ensure the computability of the model with numerous integer variables, relaxation iterations and induced acceleration processes have been developed within the algorithms to effectively nest DRO and ADMM, thereby significantly improving the model’s convergence and efficiency. Two test systems, the IEEE 33-bus system and a large-scale IEEE 123-bus system, were used to evaluate the effectiveness of the proposed model and approach.
13 April 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Aiming at the defect that the current-limiting strategy based on MMC-HVDC system only focuses on the unilateral AC-side or DC-side, this paper proposes a current -limiting strategy that is suitable for both AC-side ground fault and DC-side short-circuit fault. Firstly, for the ground fault on the AC-side, the outer-loop controller with power state equation and the inner-loop controller with passivity -based control (PBC) strategy are used to control it, and the genetic algorithm, which takes the absolute value of the difference between the reference current and the actual current as the fitness function, is used to fit the optimal injection damping parameters for the PBC method. Then, for the short-circuit fault on the DC-side, the capacitor discharge duty ratio is introduced on the basis of the equivalent capacitance without considering the voltage drop, and its segmented control is combined with the current-limiting reactors to achieve current-limiting at different fault points. Finally, a two-port +500KV HVDC transmission system was built on Matlab /Simlink software, and the effectiveness of the current-limiting method proposed in this paper was verified.