Seong Choi

Seong Choi

Auto-generated profile, based on publicly available information

Seong Choi

Department of Applied Artificial Intelligence, Sungkyunkwan University, Seoul, Republic of Korea

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2023 in Journal of Medical Internet Research
Verified
Journal Article
Open access
JYJeewoo Yoon
Jeewoo Yoon
JHJinyoung Han
Jinyoung Han
JKJunseo Ko
Junseo Ko
SCSeong Choi
Seong Choi
JPJi In Park
Ji In Park
DHDaniel Duck Jin Hwang
Daniel Duck Jin Hwang
Background: Although previous research has made substantial progress in developing high-performance artificial intelligence (AI)–based computer-aided diagnosis (AI-CAD) systems in various medical domains, little attention has been paid to developing and evaluating AI-CAD system in ophthalmology, particularly for diagnosing retinal diseases using optical coherence tomography (OCT) images. Objective: This diagnostic study aimed to determine the usefulness of a proposed AI-CAD system in assisting ophthalmologists with the diagnosis of central serous chorioretinopathy (CSC), which is known to be difficult to diagnose, using OCT images. Methods: For the training and evaluation of the proposed deep learning model, 1693 OCT images were collected and annotated. The data set included 929 and 764 cases of acute and chronic CSC, respectively. In total, 66 ophthalmologists (2 groups: 36 retina and 30 nonretina specialists) participated in the observer performance test. To evaluate the deep learning algorithm used in the proposed AI-CAD system, the training, validation, and test sets were split in an 8:1:1 ratio. Further, 100 randomly sampled OCT images from the test set were used for the observer performance test, and the participants were instructed to select a CSC subtype for each of these images. Each image was provided under different conditions: (1) without AI assistance, (2) with AI assistance with a probability score, and (3) with AI assistance with a probability score and visual evidence heatmap. The sensitivity, specificity, and area under the receiver operating characteristic curve were used to measure the diagnostic performance of the model and ophthalmologists. Results: The proposed system achieved a high detection performance (99% of the area under the curve) for CSC, outperforming the 66 ophthalmologists who participated in the observer performance test. In both groups, ophthalmologists with the support of AI assistance with a probability score and visual evidence heatmap achieved the highest mean diagnostic performance compared with that of those subjected to other conditions (without AI assistance or with AI assistance with a probability score). Nonretina specialists achieved expert-level diagnostic performance with the support of the proposed AI-CAD system. Conclusions: Our proposed AI-CAD system improved the diagnosis of CSC by ophthalmologists, which may support decision-making regarding retinal disease detection and alleviate the workload of ophthalmologists.

14 April 2023 in JMIR Preprints
Verified
Preprint
Open access
JYJeewoo Yoon
Jeewoo Yoon
JHJinyoung Han
Jinyoung Han
JKJunseo Ko
Junseo Ko
SCSeong Choi
Seong Choi
JPJi In Park
Ji In Park
DHDaniel Duck Jin Hwang
Daniel Duck Jin Hwang
BACKGROUND Although previous research has made substantial progress in developing high-performance artificial intelligence (AI)–based computer-aided diagnosis (AI-CAD) systems in various medical domains, little attention has been paid to developing and evaluating AI-CAD system in ophthalmology, particularly for diagnosing retinal diseases using optical coherence tomography (OCT) images. OBJECTIVE This diagnostic study aimed to determine the usefulness of a proposed AI-CAD system in assisting ophthalmologists with the diagnosis of central serous chorioretinopathy (CSC), which is known to be difficult to diagnose, using OCT images. METHODS For the training and evaluation of the proposed deep learning model, 1693 OCT images were collected and annotated. The data set included 929 and 764 cases of acute and chronic CSC, respectively. In total, 66 ophthalmologists (2 groups: 36 retina and 30 nonretina specialists) participated in the observer performance test. To evaluate the deep learning algorithm used in the proposed AI-CAD system, the training, validation, and test sets were split in an 8:1:1 ratio. Further, 100 randomly sampled OCT images from the test set were used for the observer performance test, and the participants were instructed to select a CSC subtype for each of these images. Each image was provided under different conditions: (1) without AI assistance, (2) with AI assistance with a probability score, and (3) with AI assistance with a probability score and visual evidence heatmap. The sensitivity, specificity, and area under the receiver operating characteristic curve were used to measure the diagnostic performance of the model and ophthalmologists. RESULTS The proposed system achieved a high detection performance (99% of the area under the curve) for CSC, outperforming the 66 ophthalmologists who participated in the observer performance test. In both groups, ophthalmologists with the support of AI assistance with a probability score and visual evidence heatmap achieved the highest mean diagnostic performance compared with that of those subjected to other conditions (without AI assistance or with AI assistance with a probability score). Nonretina specialists achieved expert-level diagnostic performance with the support of the proposed AI-CAD system. CONCLUSIONS Our proposed AI-CAD system improved the diagnosis of CSC by ophthalmologists, which may support decision-making regarding retinal disease detection and alleviate the workload of ophthalmologists.