Alexandra Makenzie

Alexandra Makenzie

Auto-generated profile, based on publicly available information

Alexandra Makenzie

Mercy Health‐Cincinnati Sports Medicine Cincinnati Ohio U.S.A.

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2026 in Arthroscopy, Sports Medicine, and Rehabilitation
Verified
Journal Article
Open access
PDF file
YSYash Sewpaul
Yash Sewpaul
AMAdam Mansour
Adam Mansour
AMAlexandra Makenzie
Alexandra Makenzie
AMAlbert Mousad
Albert Mousad
CBCasey M. Beleckas
Casey M. Beleckas
RHRobert U. Hartzler
Robert U. Hartzler
Purpose: To evaluate the short‐term clinical outcomes of subacromial balloon implantation and concomitant procedures including subscapularis repair for irreparable posterosuperior rotator cuff tears. Methods: This retrospective multicenter study included patients aged ≥40 years who underwent InSpace Balloon implantation between September 2021 and October 2024, with a minimum 12‐month follow‐up. Patients undergoing posterosuperior cuff repair were excluded. The primary outcome was the American Shoulder and Elbow Surgeons score. Secondary outcomes included Single Assessment Numeric Evaluation, Simple Shoulder Test, visual analog scale‐pain, range of motion, complications, and reoperations. Subgroup analyses compared patients with versus without subscapularis repair, those aged <65 versus ≥65, and those who underwent implantation as a revision procedure. Minimal clinically important difference and Patient Acceptable Symptom State rates were calculated using cohort‐specific thresholds. Results: Sixty patients met inclusion criteria (mean age: 68.9 ± 8.5 years; mean follow‐up: 22.3 ± 7.9 months). Statistically significant improvements were observed across all patient‐reported outcome measures (American Shoulder and Elbow Surgeons: 46.5‐72.2; Single Assessment Numeric Evaluation: 37.1‐67.7; Simple Shoulder Test: 4.6‐7.4; visual analog scale‐pain: 5.2‐2.3; all P < .001). Range of motion improved minimally. Five patients (8%) underwent revision surgery (4 reverse shoulder arthroplasty, 1 bridging graft). Clinical outcomes did not differ significantly based on subscapularis repair. Patients aged ≥65 achieved higher American Shoulder and Elbow Surgeons scores (77.7 vs 61.2, P < .001). There was no difference in outcomes when used as a primary or as a revision operation ( P = .74). Minimal clinically important difference was achieved in 72%; 30% met the Patient Acceptable Symptom State threshold. Conclusions: Subacromial balloon implantation provides significant short‐term functional and pain improvements for massive, irreparable posterosuperior rotator cuff tears, regardless of subscapularis repair. Higher clinical outcome scores were observed in patients over age 65. Level of Evidence: Level IV, retrospective therapeutic case series.

5 April 2026 in Journal of Orthopaedic Experience & Innovation
Verified
Journal Article
Open access
EMEvan Moon
Evan Moon
AMAlexandra Makenzie
Alexandra Makenzie
MGMichael Greiwe
Michael Greiwe
Purpose: The purpose of this study was to investigate the rate at which antegrade suture passers successfully passed through both the articular and bursal layers of the rotator cuff in partial- and full-thickness tears at the anterior, middle, and posterior portions of the rotator cuff during arthroscopic repair of rotator cuff tears. Methods: A consecutive series of arthroscopic rotator cuff repairs performed by a single surgeon were evaluated. An antegrade suture passer was used to pass sutures through the rotator cuff in each procedure. Successful suture placement was assessed intraoperatively by the surgeon as the ability to capture both bursal (superficial) and articular (deep) tendon layers, categorized as either a “successful” or “missed” suture placement, and success rates were calculated for each rotator cuff. Success rates were compared by tear size (<20 mm vs. ≥20 mm), tear morphology (partial-thickness vs. full-thickness), and suture position (anterior, middle, posterior). Statistical analyses were performed using the Kruskal-Wallis Test and Mann-Whitney U Test with significance set at p<0.05. Results: 102 shoulders were included in the study. The overall success rate of the suture passer was 60.56%. The mean age at operation was 61.04 ± 8.3 years (40-75 years), with a mean tear size of 20.0 ± 6.8mm (10-55mm). Although no significant difference was determined between partial-thickness (64.83%, n=29) and full-thickness tears (58.86%, n=73) (p=0.517), tears ≥ 20mm in the posterior portion of the tendon had a significantly lower success rate (45.61%, n=57) compared to the anterior and middle portions (p=0.037). Conclusion: The antegrade suture passer demonstrated an overall moderate success rate, with reduced efficacy in larger tears and in the posterior part of the tendon where delamination and deep retraction are more prevalent. Surgeons should exercise caution when using this device in complex tear morphologies with delamination of the tendon layers and in tears ≥ 20mm involving the posterior aspect of the tendon.