Li-Heng Cai

Li-Heng Cai

Auto-generated profile, based on publicly available information

Li-Heng Cai

Soft Biomatter Laboratory, Department of Materials Science and Engineering, University of Virginia, Charlottesville, USA

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2012 in Science
Verified
Journal Article
Closed access
PDF file
BBBrian Button
Brian Button
LCLi-Heng Cai
Li-Heng Cai
CECamille Ehre
Camille Ehre
MKMehmet Kesimer
Mehmet Kesimer
DHDavid B. Hill
David B. Hill
MRMichael Rubinstein
Michael Rubinstein
Sticky Mucus?: Mucus—experienced, for example, in the form of a runny nose or productive cough—is one of the tools the body uses to expel or prevent the uptake of foreign matter. In a number of diseases, a failure of the normal mucus-control system leads to obstructions of the airways and respiratory problems. Button et al. (p. 937 ; see the Perspective by Dickey ) examine the existing gel-on-liquid model, where the mucus is thought to sit on a watery periciliary layer around the beating lung cilia that has been used to explain the flow of mucus. A gel-on-brush model is proposed where the mucus sits on a brushlike periciliary layer. The key elements of this layer are membrane-tethered macromolecules that cause normal flow and clearance of mucus. When dehydrated, the interface is disrupted, preventing normal mucus motion.

11 September 2013 in Macromolecules
Verified
Journal Article
Closed access
ESEvgeny B. Stukalin
Evgeny B. Stukalin
LCLi-Heng Cai
Li-Heng Cai
NKN. Arun Kumar
N. Arun Kumar
LLLudwik Leibler
Ludwik Leibler
MRMichael Rubinstein
Michael Rubinstein

13 September 2011 in Macromolecules
Verified
Journal Article
Closed access
LCLi-Heng Cai
Li-Heng Cai
SPSergey Panyukov
Sergey Panyukov
MRMichael Rubinstein
Michael Rubinstein

2 June 2014 in Journal of Clinical Investigation
Verified
Journal Article
Open access
PDF file
AHAshley G. Henderson
Ashley G. Henderson
CECamille Ehre
Camille Ehre
BBBrian Button
Brian Button
LALubna H. Abdullah
Lubna H. Abdullah
LCLi-Heng Cai
Li-Heng Cai
MKMehmet Kesimer
Mehmet Kesimer
The pathogenesis of mucoinfective lung disease in cystic fibrosis (CF) patients likely involves poor mucus clearance. A recent model of mucus clearance predicts that mucus flow depends on the relative mucin concentration of the mucus layer compared with that of the periciliary layer; however, mucin concentrations have been difficult to measure in CF secretions. Here, we have shown that the concentration of mucin in CF sputum is low when measured by immunologically based techniques, and mass spectrometric analyses of CF mucins revealed mucin cleavage at antibody recognition sites. Using physical size exclusion chromatography/differential refractometry (SEC/dRI) techniques, we determined that mucin concentrations in CF secretions were higher than those in normal secretions. Measurements of partial osmotic pressures revealed that the partial osmotic pressure of CF sputum and the retained mucus in excised CF lungs were substantially greater than the partial osmotic pressure of normal secretions. Our data reveal that mucin concentration cannot be accurately measured immunologically in proteolytically active CF secretions; mucins are hyperconcentrated in CF secretions; and CF secretion osmotic pressures predict mucus layer–dependent osmotic compression of the periciliary liquid layer in CF lungs. Consequently, mucin hypersecretion likely produces mucus stasis, which contributes to key infectious and inflammatory components of CF lung disease.

22 January 2015 in Macromolecules
Verified
Journal Article
Open access
LCLi-Heng Cai
Li-Heng Cai
SPSergey Panyukov
Sergey Panyukov
MRMichael Rubinstein
Michael Rubinstein
We propose a hopping mechanism for diffusion of large nonsticky nanoparticles subjected to topological constraints in both unentangled and entangled polymer solids (networks and gels) and entangled polymer liquids (melts and solutions). Probe particles with size larger than the mesh size ax of unentangled polymer networks or tube diameter ae of entangled polymer liquids are trapped by the network or entanglement cells. At long time scales, however, these particles can diffuse by overcoming free energy barrier between neighboring confinement cells. The terminal particle diffusion coefficient dominated by this hopping diffusion is appreciable for particles with size moderately larger than the network mesh size ax or tube diameter ae. Much larger particles in polymer solids will be permanently trapped by local network cells, whereas they can still move in polymer liquids by waiting for entanglement cells to rearrange on the relaxation time scales of these liquids. Hopping diffusion in entangled polymer liquids and networks has a weaker dependence on particle size than that in unentangled networks as entanglements can slide along chains under polymer deformation. The proposed novel hopping model enables understanding the motion of large nanoparticles in polymeric nanocomposites and the transport of nano drug carriers in complex biological gels such as mucus.

10 August 2015 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
LCLi‐Heng Cai
Li‐Heng Cai
TKThomas E. Kodger
Thomas E. Kodger
RGRodrigo E. Guerra
Rodrigo E. Guerra
APAdrian F. Pegoraro
Adrian F. Pegoraro
MRMichael Rubinstein
Michael Rubinstein
DWDavid A Weitz
David A Weitz