23 August 2024 in IEEE Transactions on Power Delivery
The cascaded diode rectifier (DR)- MMC based HVDC system is recognized as a promising topology for integrating offshore wind farms. However, the capacity design of DR-MMC remains an unsolved challenge. This paper proposes a capacity design method based on operating region (OR) analysis. First, the analytical models of DR-MMC with V - F grid-forming (GFM) control are established, revealing its operating characteristics. Then, considering multiple constraints, the OR of DR-MMC is calculated. The impact of different MMC capacities on OR is analyzed, highlighting that a system with a low MMC capacity ratio may be incapable of covering its full active power range. Hence, a three-layer GFM control utilizing MMC DC voltage is proposed, enabling operation under a lower MMC capacity ratio. Then, an optimal MMC capacity ratio is determined by balancing the system stability margin and economic considerations. Finally, the effectiveness of the designed MMC capacity with the proposed three-layer GFM control is validated by stability analysis and simulations in PSCAD/EMTDC.
11 September 2023 in IEEE Transactions on Power Delivery
The diode rectifier- modular multilevel converter (DR-MMC) based hybrid HVDC system is an attractive topology for integrating large-scale offshore wind power. To investigate the interaction stability of the cascaded DR-MMC converter integrating with offshore wind farms, this article proposes the sequence impedance model considering frequency coupling among DR, MMC, controllers and DR commutation process. Firstly, the frequency interaction between DRs and MMC at the DC side is disclosed. Then, using the equivalent impedance method, frequency-coupling terms that mainly affect impedance characteristics are analyzed. The impacts of wind power curtailments and two reactive power compensation methods on wideband impedance characteristics are revealed. It is shown that the decrease of wind power will weaken the system phase margin. And the reactive power compensation via MMC is more prone to instability than that via AC filters. Besides, the impedance characteristics and stability between DR-MMC and classic MMC systems are compared. The correctness of stability analysis based on the proposed sequence impedance models is validated by simulations in PSCAD/EMTDC.
10 February 2023 in IEEE Transactions on Power Delivery
The push-pull DC autotransformer (PPDAT) is a potential power equipment to interconnect the MMC and LCC HVDC systems. However, the harmonic stability of the PPDAT remains an unsolved challenge. In this paper, considering the dual closed-loop control and bidirectional DC voltage operation of the PPDAT, its DC impedance models are proposed using the harmonic transfer function (HTF) method. Both the DC impedance models at the high/low voltage side considering the harmonic coupling and internal dynamics of the hybrid MMC/LCC HVDC system are deduced. The accuracy of the detailed DC impedance models is validated in PSCAD/EMTDC simulations. The impedance analysis under bidirectional DC voltage operation scenarios reveals that the DC voltage polarity affects the low frequency region. Besides, the main impact of PPDAT's parameters on the wideband impedance characteristics is disclosed. It shows that unreasonable parameter design will bring negative damping characteristics near the resonance point (RP). Moreover, stability analysis considering the interaction of PPDAT and LCC-HVDC at the high-voltage side is conducted. The results indicate that the potential resonances can be readily predicted through the Nyquist diagrams and the negative damping of the PPDAT may cause instability at RP.