Abdul Rahman Khan

Abdul Rahman Khan

Auto-generated profile, based on publicly available information

Abdul Rahman Khan

Department of Mechanical Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016, India and Department of Mechanical Engineering, G. H. Raisoni College of Engineering, Nagpur, Maharashtra 440016, India

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2017 in Fuel
Verified
Journal Article
Closed access
AKA.R. Khan
A.R. Khan
SAS. Anbusaravanan
S. Anbusaravanan
LKLokesh Kalathi
Lokesh Kalathi
RVRatna Kishore Velamati
Ratna Kishore Velamati
CPC. Prathap
C. Prathap


1 October 2020 in Physical Review Fluids
Verified
Journal Article
Closed access
PDF file
MSManjinder Singh
Manjinder Singh
AKAvinash Kumar
Avinash Kumar
AKAbdul Rahman Khan
Abdul Rahman Khan
We present a theoretical investigation of liquid imbibition into capillaries with axially varying geometry. We show that using appropriate geometry and wettability, converging capillaries, in principle, can act as a liquid diode. We explain the underlying mechanics and conditions that make a converging capillary a liquid diode. Further, we describe a methodology to enhance the rate of liquid imbibition into the proposed diode. We mathematically show that creating a wettability gradient along the axial length of the capillary diode enhances the rate of liquid imbibition compared to a capillary diode with uniform wettability. Our mathematical model predicts that using a wettability gradient along the axial length of the capillary diode decreases the imbibition time by more than 30% compared to a capillary diode with uniform wettability.

28 January 2019 in Combustion Science and Technology
Verified
Journal Article
Closed access
AKA.R. Khan
A.R. Khan
MRM.R. Ravi
M.R. Ravi
ARAnjan Ray
Anjan Ray
The primary objective of the present work is to systematically study the effect of higher hydrocarbon (HC) content on laminar burning velocity (LBV) and flame stability of various natural gas (NG) blends. Following the central composite design of experiments, proportions of methane, ethane, and propane are varied in the NG blends. All the experiments are performed at 0.1 MPa pressure and 300 ± 3 K temperature using constant pressure outwardly propagating spherical flame method. PREMIX code of CHEMKIN-PRO® is used to compute laminar burning velocities. Experimental results and trends are correlated with an available theoretical expression of LBV based on asymptotic analysis. Presence of higher HC modifies the transport and thermo–kinetic parameters of fuel–air mixtures. The presence of higher HC increases the concentrations of active radicals which ultimately increases the LBV. NG blends have higher burned gas Markstein length compared to pure alkane fuels. Numerical study shows that GRI-3.0 performs well for rich fuel–air mixtures, while predictions of San Diego and USC-II are good for lean fuel–air mixtures. Based on sensitivity analysis and recommendations from the literature, Arrhenius rate parameters of some of the elementary reactions are modified for GRI-3.0 mechanism. Simulations with three variants of the modified GRI-3.0 mechanism show good agreement with the experimental results.

1 January 2016 in The Proceedings of the National Symposium on Power and Energy Systems
Verified
Journal Article
Closed access
PDF file
HGHaiguang Gong
Haiguang Gong
AKAbdul Khan
Abdul Khan
NENejdet Erkan
Nejdet Erkan
LWLaishun Wang
Laishun Wang
KOKoji Okamoto
Koji Okamoto
Ex-vessel cooling is an important subject in the field of nuclear safety so that many researchers focus on CHF (critical heat flux) enhancement study of pressure vessel reactor. In this study, pool boiling experiment is carried out to test CHF value. Meanwhile, a new structure design, honeycomb plate, is introduced for enhancement study of CHF. During experiment, different kind of plates are utilized. It is found that CHF can be enhanced after using honeycomb structure. Also, porous plate can further increase CHF compared with solid plate.