Naga Chaitanya Kavuri

Naga Chaitanya Kavuri

Auto-generated profile, based on publicly available information

Naga Chaitanya Kavuri

Anant School for Climate Action, Anant National University, Ahmedabad, India

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2011 in Brazilian Journal of Chemical Engineering
Verified
Journal Article
Open access
PDF file
SSS. Sahu
S. Sahu
NKN. C. Kavuri
N. C. Kavuri
MKMadhusree Kundu
Madhusree Kundu
The dissolution kinetics of nickel laterite ore in aqueous acid solutions of three metabolic acids, i.e., citric acid, oxalic acid and acetic acid were investigated in a batch reactor individually. It was determined that experimental data comply with a shrinking core model. The diffusion coefficients for citric acid, oxalic acid and acetic acid were found to be 1.99×10-9 cm²/s, 2.59×10-8 cm²/s and 1.92×10-10 cm²/s respectively. The leaching ability of each acid was observed and it was found that oxalic acid was better than the other two

1 June 2015 in Particuology
Verified
Journal Article
Closed access
NKNaga Chaitanya Kavuri
Naga Chaitanya Kavuri
KPKakoli Karar Paul
Kakoli Karar Paul
NRNagendra Roy
Nagendra Roy

24 September 2026 in Scientific Reports
Verified
Journal Article
Open access
PDF file
PKPrisha Kakade
Prisha Kakade
MRM. Achyutha Kumar Reddy
M. Achyutha Kumar Reddy
NKNaga Chaitanya Kavuri
Naga Chaitanya Kavuri
RDRohan Dutta
Rohan Dutta
With accelerating climate change, reducing emissions due to heating/cooling built environment has become critical, as conventional vapour-compression heating/cooling systems are responsible for emissions of greenhouse gases due to both electricity use and refrigerant life-cycle. This work presents the design and analysis of an Earth–Air Refrigeration System (EARS) using earth–air heat exchanger (EAHE) as a low-Carbon alternative for space cooling in hot and dry climatic regions. A pilot-scale EARS system was designed for a 1 cubic-meter test hut and its performance has been analysed experimentally and thermodynamically using a one-dimensional transient heat-transfer model. The experimental results show a reduction in the indoor temperature of the hut by around 10 °C compared to the ambient air during the peak sun hours. Similar reduction has also been predicted by the thermodynamic model with deviation from experimental results within the range of – 2.41% to 6.39%. This validated the capability of the thermodynamic model developed and it has been further used to predict the performance of the EAHE using parametric studies on pipe materials, air flow rate, etc. The results of the studies show: (a) the marginal effect of variations in pipe materials on outlet air temperature, (b) the dominance of air-side convection and soil conduction in the overall heat transfer co-efficient of the EAHE, (c) the performance of EAHE is more sensitive to flow conditions and geometric configuration than to the choice of pipe material, (d) the optimum performance was observed at an air flow rate of 0.5–1.0 kg/s with the length of the and an EAHE length of 6–12 m when PVC was used as the pipe material.