Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2014 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
PTPhillip Tran
Phillip Tran
ASAndrian Sue
Andrian Sue
PWPaul Wong
Paul Wong
QLQing Li
Qing Li
PCPaul Carter
Paul Carter
The current conduction pathways resulting from monopolar stimulation of the cochlear implant were studied by developing a human electroanatomical total head reconstruction (namely, HEATHER). HEATHER was created from serially sectioned images of the female Visible Human Project dataset to encompass a total of 12 different tissues, and included computer-aided design geometries of the cochlear implant. Since existing methods were unable to generate the required complexity for HEATHER, a new modeling workflow was proposed. The results of the finite-element analysis agree with the literature, showing that the injected current exits the cochlea via the modiolus (14%), the basal end of the cochlea (22%), and through the cochlear walls (64%). It was also found that, once leaving the cochlea, the current travels to the implant body via the cranial cavity or scalp. The modeling workflow proved to be robust and flexible, allowing for meshes to be generated with substantial user control. Furthermore, the workflow could easily be employed to create realistic anatomical models of the human head for different bioelectric applications, such as deep brain stimulation, electroencephalography, and other biophysical phenomena.

22 September 2015 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
PWPaul Wong
Paul Wong
SGShefin George
Shefin George
PTPhillip Tran
Phillip Tran
ASAndrian Sue
Andrian Sue
PCPaul Carter
Paul Carter
QLQing Li
Qing Li
Goal: To validate a new electroanatomical model of the implanted guinea pig cochlea against independently obtained in vivo voltage tomography data, and evaluate the validity of exist-ing modeling assumptions on current paths and neural excitation. Methods: An in silico model was generated from sTSLIM images and analyzed in COMSOL Multiphysics. Tissue resistivities and boundary conditions were varied to test model sensitivity. Results: The simulation was most sensitive to the resistivities of bone, perilymph, and nerve. Bone tissue in particular should be separated by morphology because different types of bone have different electrical properties. Despite having a strong impact on intrascalar voltages and exit pathways, most boundary conditions, including a new alternative proposed to account for the unmodeled return path, only had a weak effect on neural excitation. Conclusion: The new model demonstrated a strong correlation with the in vivo voltage data. Significance: These findings address a long-standing knowledge gap about appropriate boundary conditions, and will help to promote wider acceptance of insights from computational models of the cochlea.

24 October 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
FZFan-Gang Zeng
Fan-Gang Zeng
PTPhillip Tran
Phillip Tran
MRMatthew Richardson
Matthew Richardson
SSShuping Sun
Shuping Sun
YXYuchen Xu
Yuchen Xu
Noninvasive transcranial electric stimulation is increasingly being used as an advantageous therapy alternative that may activate deep tissues while avoiding drug side-effects. However, not only is there limited evidence for activation of deep tissues by transcranial electric stimulation, its evoked human sensation is understudied and often dismissed as a placebo or secondary effect. By systematically characterizing the human sensation evoked by transcranial alternating-current stimulation, we observed not only stimulus frequency and electrode position dependencies specific for auditory and visual sensation but also a broader presence of somatic sensation ranging from touch and vibration to pain and pressure. We found generally monotonic input-output functions at suprathreshold levels, and often multiple types of sensation occurring simultaneously in response to the same electric stimulation. We further used a recording circuit embedded in a cochlear implant to directly and objectively measure the amount of transcranial electric stimulation reaching the auditory nerve, a deep intercranial target located in the densest bone of the skull. We found an optimal configuration using an ear canal electrode and low-frequency (<300 Hz) sinusoids that delivered maximally ~1% of the transcranial current to the auditory nerve, which was sufficient to produce sound sensation even in deafened ears. Our results suggest that frequency resonance due to neuronal intrinsic electric properties need to be explored for targeted deep brain stimulation and novel brain-computer interfaces.

9 January 2019 in Trends in Hearing
Verified
Journal Article
Open access
FZFan-Gang Zeng
Fan-Gang Zeng
MRMatthew Richardson
Matthew Richardson
PTPhillip Tran
Phillip Tran
HLHarrison Lin
Harrison Lin
HDHamid Djalilian
Hamid Djalilian
Noninvasive transcranial or minimally invasive transtympanic electric stimulation may offer a desirable treatment option for tinnitus because it can activate the deafferented auditory nerve fibers while posing little to no risk to hearing. Here, we built a flexible research interface to generate and control accurately charge-balanced current stimulation as well as a head-mounted instrument capable of holding a transtympanic electrode steady for hours. We then investigated the short-term effect of a limited set of electric stimulation parameters on tinnitus in 10 adults with chronic tinnitus. The preliminary results showed that 63% of conditions of electric stimulation produced some degree of tinnitus reduction, with total disappearance of tinnitus in six subjects in response to at least one condition. The present study also found significant side effects such as visual, tactile, and even pain sensations during electric stimulation. In addition to masking and residual inhibition, neuroplasticity is likely involved in the observed tinnitus reduction. To translate the present electric stimulation into a safe and effective tinnitus treatment option, we need to optimize stimulation parameters that activate the deafferented auditory nerve fibers and reliably suppress tinnitus, with minimal side effects and tolerable sensations. Noninvasive or minimally invasive electric stimulation can be integrated with sound therapy, invasive cochlear implants, or other forms of coordinated stimulation to provide a systematic strategy for tinnitus treatment or even a cure.

11 November 2019 in Neuromodulation: Technology at the Neural Interface
Verified
Journal Article
Open access
PDF file
PTPhillip Tran
Phillip Tran
MRMatthew L. Richardson
Matthew L. Richardson
FZFan-Gang Zeng
Fan-Gang Zeng
Objectives Electric stimulation is used to treat a number of neurologic disorders such as epilepsy and depression. However, delivering the required current to far-field neural targets is often ineffective because of current spread through low-impedance pathways. Here, the specific aims are to develop an empirical measure for current passing through the human head and to optimize stimulation strategies for targeting deeper structures, including the auditory nerve, by utilizing the cochlear implant (CI). Materials and Methods Outward input/output (I/O) functions were obtained by CI stimulation and recording scalp potentials in five CI subjects. Conversely, inward I/O functions were obtained by noninvasive transcranial electric stimulation (tES) and recording intracochlear potentials using the onboard recording capability of the CI. Results I/O measures indicate substantial current spread, with a maximum of 2.2% gain recorded at the inner ear target during tES (mastoid-to-mastoid electrode configuration). Similarly, CI stimulation produced a maximum of 1.1% gain at the scalp electrode nearest the CI return electrode. Gain varied with electrode montage according to a point source model that accounted for distances between the stimulating and recording electrodes. Within the same electrode montages, current gain patterns varied across subjects suggesting the importance of tissue properties, geometry, and electrode positioning. Conclusion These results provide a novel objective measure of electric stimulation in the human head, which can help to optimize stimulation parameters that improve neural excitation of deep structures by reducing the influence of current spread.

1 July 2013
Verified
Conference Paper
Closed access
PTPhillip Tran
Phillip Tran
PWPaul Wong
Paul Wong
ASAndrian Sue
Andrian Sue
QLQing Li
Qing Li
PCPaul Carter
Paul Carter
It is known that the inclusion of blood vessels in finite element (FE) models can influence the current conduction results. However, there have been no studies exploring the impact of blood vessel conductivity on human head models for cochlear implant (CI) stimulation. The three-dimensional (3D) FE model presented in this paper aims to provide understanding in this regard. The electrical conductivity of blood was varied to determine the sensitivity of the 3D model. The results show that some of the current is exiting the cochlea and taking the jugular vein pathway. When compared to the case with blood vessels being omitted, the current density in the blood increased by 13.1%, 17.2% and 20.7% for low, medium and high electrical conductivity cases considered, respectively. This study suggests that blood vessels cannot be neglected from CI models as the jugular vein can provide a low impedance pathway, through which current can leave the cochlea. It also indicates the importance of using correct tissue property values for performing accurate bioelectric modeling analyses.