C. Anderson Engh

C. Anderson Engh

Auto-generated profile, based on publicly available information

C. Anderson Engh

Anderson Orthopaedic Research Institute, Alexandria, Virginia

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2006 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
CEC Anderson Engh
C Anderson Engh
ASAdam S Stepniewski
Adam S Stepniewski
SGStuart D Ginn
Stuart D Ginn
SBSarah E Beykirch
Sarah E Beykirch
CSChristi J Sychterz-Terefenko
Christi J Sychterz-Terefenko
CECharles A Engh
Charles A Engh

1 August 2005 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
TWTim A Walde
Tim A Walde
DWDaniel E Weiland
Daniel E Weiland
SLSerena B Leung
Serena B Leung
NKNobuto Kitamura
Nobuto Kitamura
CSChristi J Sychterz
Christi J Sychterz
CECharles A Engh
Charles A Engh
In this study, we compared the accuracy of radiography, computed tomography, and magnetic resonance imaging in assessing periacetabular osteolytic lesions. Using a previously published cadaver model, we created 87 lesions in pelves implanted with total hip replacement components. The sensitivity for detecting lesions was 51.7% for radiography, 74.7% for computed tomography, and 95.4% for magnetic resonance imaging. For all three techniques, sensitivity increased as lesion size increased. Magnetic resonance imaging emerged as the most effective tool for detecting small periacetabular osteolytic lesions (< or = 3 cm). For lesions larger than 3 cm, which are of more concern clinically, computed tomography and magnetic resonance imaging were effective in identifying lesions with detection rates greater than 80%. For radiography and computed tomography, lesion detection was dependent on lesion location, whereas magnetic resonance imaging had consistently good sensitivity in all lesion locations. Although the mean volumetric errors for computed tomography and magnetic resonance imaging (0.3 cm and 0.8 cm) were small compared with mean lesion volume (6.1 cm), computed tomography was more accurate than magnetic resonance imaging at measuring lesion volume, with a lower mean absolute error. This study verifies the problems associated with radiographic detection of osteolysis while showing the effectiveness of computed tomography and magnetic resonance imaging in determining the presence of lesions and assessing their three-dimensional volume.

1 September 2012 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
CECharles A. Engh
Charles A. Engh
RHRobert H. Hopper
Robert H. Hopper
CHCathy Huynh
Cathy Huynh
HHHenry Ho
Henry Ho
SSSupatra Sritulanondha
Supatra Sritulanondha

1 February 2000 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
WCWei-Ming Chen
Wei-Ming Chen
CEC. Anderson Engh
C. Anderson Engh
RHRobert H. Hopper
Robert H. Hopper
JMJAMES P. McAULEY
JAMES P. McAULEY
Purpose of this study was to assess the results with use of a bilobed acetabular component inserted without cement for revision reconstruction in hips with acetabular bone deficiency in order to clarify the indications for its use and to identify the factors that influence the clinical and radiographic outcome....

1 June 2007 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
MCMatthew B. Collier
Matthew B. Collier
CEC. Anderson Engh
C. Anderson Engh
JMJames P. McAuley
James P. McAuley
GEGerard A. Engh
Gerard A. Engh
Of thickness loss in polyethylene tibial bearings that were retrieved at the time of revision surgery or after the death of the patient....

1 September 2000 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
WCWei-Ming Chen
Wei-Ming Chen
JMJAMES P. McAULEY
JAMES P. McAULEY
CEC. Anderson Engh
C. Anderson Engh
RHRobert H. Hopper
Robert H. Hopper
The purpose of this study was to assess the rate of union, time to union, and complications associated with the extended slide trochanteric osteotomy. We also evaluated how outcomes were influenced by the preoperative cortical-bone thickness, the preoperative cancellous-bone quality of the greater trochanter, the number of cables used to reattach the trochanteric osteotomy fragment, and the use of cortical strut augmentation. We reviewed the results for forty-six hips in forty-five patients who underwent a revision total hip arthroplasty with an extended slide trochanteric osteotomy between December 1991 and December 1996. Twenty-three patients were men, and twenty-two were women; the mean age at the time of the operation was 66.3 years. Two hips had an isolated acetabular revision, fifteen had an isolated femoral revision, and twenty-nine had acetabular and femoral revisions. One patient (one hip) was lost to follow-up. At a mean of forty-four months after the operation, the rate of union of the distal osteotomy site was 98 percent (forty-four of forty-five hips), with no change in the femoral component position. The time to union was not significantly correlated with the number of cables, the preoperative cortical-bone thickness, or the preoperative cancellous-bone quality of the greater trochanter. Interestingly, the time to bridging-callus union was significantly longer in the hips with a strut allograft than in the hips without a strut allograft (p = 0.04, t test for independent samples). Two fractures of the osteotomy fragment occurred, but neither necessitated another revision. The extended slide trochanteric osteotomy allows extensive acetabular and femoral exposure, facilitates removal of distal cement or a well fixed porous-coated stem, and allows reliable reattachment and healing of the trochanteric fragment.