Alejandro Noriega

Alejandro Noriega

Auto-generated profile, based on publicly available information

Alejandro Noriega

Prosperia Salud S.A. de C.V.

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2021 in JMIR Formative Research
Verified
Journal Article
Open access
ANAlejandro Noriega
Alejandro Noriega
DMDaniela Meizner
Daniela Meizner
DCDalia Camacho
Dalia Camacho
JEJennifer Enciso
Jennifer Enciso
HQHugo Quiroz-Mercado
Hugo Quiroz-Mercado
APAlex Pentland
Alex Pentland
Background: The automated screening of patients at risk of developing diabetic retinopathy represents an opportunity to improve their midterm outcome and lower the public expenditure associated with direct and indirect costs of common sight-threatening complications of diabetes. Objective: This study aimed to develop and evaluate the performance of an automated deep learning–based system to classify retinal fundus images as referable and nonreferable diabetic retinopathy cases, from international and Mexican patients. In particular, we aimed to evaluate the performance of the automated retina image analysis (ARIA) system under an independent scheme (ie, only ARIA screening) and 2 assistive schemes (ie, hybrid ARIA plus ophthalmologist screening), using a web-based platform for remote image analysis to determine and compare the sensibility and specificity of the 3 schemes. Methods: A randomized controlled experiment was performed where 17 ophthalmologists were asked to classify a series of retinal fundus images under 3 different conditions. The conditions were to (1) screen the fundus image by themselves (solo); (2) screen the fundus image after exposure to the retina image classification of the ARIA system (ARIA answer); and (3) screen the fundus image after exposure to the classification of the ARIA system, as well as its level of confidence and an attention map highlighting the most important areas of interest in the image according to the ARIA system (ARIA explanation). The ophthalmologists’ classification in each condition and the result from the ARIA system were compared against a gold standard generated by consulting and aggregating the opinion of 3 retina specialists for each fundus image. Results: The ARIA system was able to classify referable vs nonreferable cases with an area under the receiver operating characteristic curve of 98%, a sensitivity of 95.1%, and a specificity of 91.5% for international patient cases. There was an area under the receiver operating characteristic curve of 98.3%, a sensitivity of 95.2%, and a specificity of 90% for Mexican patient cases. The ARIA system performance was more successful than the average performance of the 17 ophthalmologists enrolled in the study. Additionally, the results suggest that the ARIA system can be useful as an assistive tool, as sensitivity was significantly higher in the experimental condition where ophthalmologists were exposed to the ARIA system’s answer prior to their own classification (93.3%), compared with the sensitivity of the condition where participants assessed the images independently (87.3%; P=.05). Conclusions: These results demonstrate that both independent and assistive use cases of the ARIA system present, for Latin American countries such as Mexico, a substantial opportunity toward expanding the monitoring capacity for the early detection of diabetes-related blindness.

28 August 2024 in medRxiv
Verified
Preprint
Open access
PDF file
DCDalia Camacho-García-Formentí
Dalia Camacho-García-Formentí
GBGabriela Baylón-Vázquez
Gabriela Baylón-Vázquez
KAKaren Arriozola-Rodríguez
Karen Arriozola-Rodríguez
EAEnrique Avalos-Ramirez
Enrique Avalos-Ramirez
CHCurt Hartleben-Matkin
Curt Hartleben-Matkin
ANAlejandro Noriega
Alejandro Noriega
Background: Artificial intelligence (AI) shows promise in ophthalmology, but its potential on tertiary care settings in Latin America remains understudied. We evaluated a Mexican AI-powered screening tool, against first-year ophthalmology residents in a tertiary care setting in Mexico City. Methods: We analysed 435 adult patients undergoing their first ophthalmic evaluation. AI and residents’ assessments were compared against expert annotations for retinal disease, cup-to-disk ratio (CDR) measurements, and glaucoma suspect classification. We also evaluated a synergistic approach combining AI and resident assessments. Results: For glaucoma suspect classification, AI outperformed residents in accuracy (88.6% vs 82.9%, p = 0.016), sensitivity (63.0% vs 50.0%, p = 0.116), and specificity (94.5% vs 90.5%, p = 0.062). The synergistic approach deemed a higher sensitivity (80.4%) than ophthalmic residents alone or AI alone ( p < 0.001). AI’s CDR estimates showed lower mean absolute error (0.056 vs 0.105, p < 0.001) and higher correlation with expert measurements ( r = 0.728 vs r = 0.538). In retinal disease assessment, AI demonstrated higher sensitivity (90.1% vs 63.0% for medium/high-risk, p < 0.001) and specificity (95.8% vs 90.4%, p < 0.001). Furthermore, differences between AI and residents were statistically significant across all metrics. The synergistic approach achieved the highest sensitivity for retinal disease (92.6% for medium/high-risk, 100% for high-risk). Conclusion: AI outperforms first-year residents in key ophthalmic assessments. The synergistic use of AI and resident assessments shows potential for optimizing diagnostic accuracy, highlighting the value of AI as a supportive tool in ophthalmic practice, especially for early-career clinicians.

26 July 2020 in medRxiv
Verified
Preprint
Open access
PDF file
ANAlejandro Noriega
Alejandro Noriega
DMDaniela Meizner
Daniela Meizner
DCDalia Camacho
Dalia Camacho
JEJennifer Enciso
Jennifer Enciso
HQHugo Quiroz-Mercado
Hugo Quiroz-Mercado
APAlex Pentland
Alex Pentland
Background: The automated screening of patients at risk of developing diabetic retinopathy (DR) represents an opportunity to improve their mid-term outcome, and lower the public expenditure associated with direct and indirect costs of common sight-threatening complications of diabetes. Objective: In the present study, we aim at developing and evaluating the performance of an automated deep learning–based system to classify retinal fundus images from international and Mexican patients, as referable and non-referable DR cases. In particular, we study the performance of the automated retina image analysis (ARIA) system under an independent scheme (i.e. only ARIA screening) and two assistive schemes (i.e., hybrid ARIA + ophthalmologist screening), using a web-based platform for remote image analysis. Methods: We ran a randomized controlled experiment where 17 ophthalmologists were asked to classify a series of retinal fundus images under three different conditions: 1) screening the fundus image by themselves ( solo ), 2) screening the fundus image after being exposed to the opinion of the ARIA system ( ARIA answer ), and 3) screening the fundus image after being exposed to the opinion of the ARIA system, as well as its level of confidence and an attention map highlighting the most important areas of interest in the image according to the ARIA system ( ARIA explanation ). The ophthalmologists’ opinion in each condition and the opinion of the ARIA system were compared against a gold standard generated by consulting and aggregating the opinion of three retina specialists for each fundus image. Results: The ARIA system was able to classify referable vs. non-referable cases with an area under the Receiver Operating Characteristic curve (AUROC), sensitivity, and specificity of 98%, 95.1% and 91.5% respectively, for international patient-cases; and an AUROC, sensitivity, and specificity of 98.3%, 95.2%, and 90% respectively for Mexican patient-cases. The results achieved on Mexican patient-cases outperformed the average performance of the 17 ophthalmologist participants of the study. We also find that the ARIA system can be useful as an assistive tool, as significant sensitivity improvements were observed in the experimental condition where participants were exposed to the answer of the ARIA system as a second opinion (93.3%), compared to the sensitivity of the condition where participants assessed the images independently (87.3%). Conclusions: These results demonstrate that both use cases of ARIA systems, independent and assistive , present a substantial opportunity for Latin American countries like Mexico towards an efficient expansion of monitoring capacity for the early detection of diabetes-related blindness.

18 November 2020 in JMIR Preprints
Verified
Preprint
Open access
ANAlejandro Noriega
Alejandro Noriega
DMDaniela Meizner
Daniela Meizner
DCDalia Camacho
Dalia Camacho
JEJennifer Enciso
Jennifer Enciso
HQHugo Quiroz-Mercado
Hugo Quiroz-Mercado
APAlex Pentland
Alex Pentland
BACKGROUND The automated screening of patients at risk of developing diabetic retinopathy represents an opportunity to improve their midterm outcome and lower the public expenditure associated with direct and indirect costs of common sight-threatening complications of diabetes. OBJECTIVE This study aimed to develop and evaluate the performance of an automated deep learning–based system to classify retinal fundus images as referable and nonreferable diabetic retinopathy cases, from international and Mexican patients. In particular, we aimed to evaluate the performance of the automated retina image analysis (ARIA) system under an independent scheme (ie, only ARIA screening) and 2 assistive schemes (ie, hybrid ARIA plus ophthalmologist screening), using a web-based platform for remote image analysis to determine and compare the sensibility and specificity of the 3 schemes. METHODS A randomized controlled experiment was performed where 17 ophthalmologists were asked to classify a series of retinal fundus images under 3 different conditions. The conditions were to (1) screen the fundus image by themselves (solo); (2) screen the fundus image after exposure to the retina image classification of the ARIA system (ARIA answer); and (3) screen the fundus image after exposure to the classification of the ARIA system, as well as its level of confidence and an attention map highlighting the most important areas of interest in the image according to the ARIA system (ARIA explanation). The ophthalmologists’ classification in each condition and the result from the ARIA system were compared against a gold standard generated by consulting and aggregating the opinion of 3 retina specialists for each fundus image. RESULTS The ARIA system was able to classify referable vs nonreferable cases with an area under the receiver operating characteristic curve of 98%, a sensitivity of 95.1%, and a specificity of 91.5% for international patient cases. There was an area under the receiver operating characteristic curve of 98.3%, a sensitivity of 95.2%, and a specificity of 90% for Mexican patient cases. The ARIA system performance was more successful than the average performance of the 17 ophthalmologists enrolled in the study. Additionally, the results suggest that the ARIA system can be useful as an assistive tool, as sensitivity was significantly higher in the experimental condition where ophthalmologists were exposed to the ARIA system’s answer prior to their own classification (93.3%), compared with the sensitivity of the condition where participants assessed the images independently (87.3%; P=.05). CONCLUSIONS These results demonstrate that both independent and assistive use cases of the ARIA system present, for Latin American countries such as Mexico, a substantial opportunity toward expanding the monitoring capacity for the early detection of diabetes-related blindness.

12 June 2016
Verified
Book Chapter
Closed access
PDF file
BWBrian Wheatman
Brian Wheatman
ANAlejandro Noriega
Alejandro Noriega
APAlex Pentland
Alex Pentland

7 November 2018 in arXiv
Verified
Preprint
Open access
PDF file
ANAlejandro Noriega-Campero
Alejandro Noriega-Campero
MBMichiel A. Bakker
Michiel A. Bakker
BGBernardo Garcia-Bulle
Bernardo Garcia-Bulle
APAlex Pentland
Alex Pentland
Society increasingly relies on machine learning models for automated decision making. Yet, efficiency gains from automation have come paired with concern for algorithmic discrimination that can systematize inequality. Recent work has proposed optimal post-processing methods that randomize classification decisions for a fraction of individuals, in order to achieve fairness measures related to parity in errors and calibration. These methods, however, have raised concern due to the information inefficiency, intra-group unfairness, and Pareto sub-optimality they entail. The present work proposes an alternative active framework for fair classification, where, in deployment, a decision-maker adaptively acquires information according to the needs of different groups or individuals, towards balancing disparities in classification performance. We propose two such methods, where information collection is adapted to group- and individual-level needs respectively. We show on real-world datasets that these can achieve: 1) calibration and single error parity (e.g., equal opportunity); and 2) parity in both false positive and false negative rates (i.e., equal odds). Moreover, we show that by leveraging their additional degree of freedom, active approaches can substantially outperform randomization-based classifiers previously considered optimal, while avoiding limitations such as intra-group unfairness.