Angela P. Paul

Angela P. Paul

Auto-generated profile, based on publicly available information

Angela P. Paul

Nevada Water Science Center, US Geological Survey, Carson City, USA

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2012
Verified
Report
Closed access
DADavid W. Anning
David W. Anning
APAngela P. Paul
Angela P. Paul
TMTim S. McKinney
Tim S. McKinney
JHJena M. Huntington
Jena M. Huntington
LBLaura M. Bexfield
Laura M. Bexfield
STSusan A. Thiros
Susan A. Thiros


1 January 2007
Verified
Report
Closed access
APAngela P. Paul
Angela P. Paul
RSRalph L. Seiler
Ralph L. Seiler
TRTimothy G. Rowe
Timothy G. Rowe
MRMichael Rosen
Michael Rosen
The results of this investigation show that nitrate, the principal species of nitrogen present in ground water, exceeds the U.S. Environmental Protection Agency (USEPA) maximum contaminant level (MCL) of 10 milligrams per liter in water from more than 25 percent of agricultural wells and 10 percent of urban wells. In agricultural areas, the probability of exceeding the USEPA MCL for nitrate is influenced primarily by three factors: fertilizer use, irrigation, and aquifer oxidation-reduction (redox) conditions. At the study-unit level, differences in nutrient concentrations between agricultural and urban land use likely are influenced by ground-water redox conditions within respective aquifer systems.

1 January 2016
Verified
Report
Closed access
PDF file
APAngela P. Paul
Angela P. Paul
JGJohn R. Garbarino
John R. Garbarino
LOLisa D Olsen
Lisa D Olsen
MRMichael Rosen
Michael Rosen
CMChristopher A. Mebane
Christopher A. Mebane
TSTedmund M. Struzeski
Tedmund M. Struzeski
First posted September 28, 2016 Chief, Water Science Field Team U.S. Geological Survey 520 North Park Avenue Tucson, Arizona 85721 http://az.water.usgs.gov/ Potential sources of analytical bias and error associated with laboratory analyses for selected trace elements where concentrations were greater in filtered samples than in paired unfiltered samples were evaluated by U.S. Geological Survey (USGS) Water Quality Specialists in collaboration with the USGS National Water Quality Laboratory (NWQL) and the Branch of Quality Systems (BQS). Causes for trace-element concentrations in filtered samples to exceed those in associated unfiltered samples have been attributed to variability in analytical measurements, analytical bias, sample contamination either in the field or laboratory, and (or) sample-matrix chemistry. These issues have not only been attributed to data generated by the USGS NWQL but have been observed in data generated by other laboratories. This study continues the evaluation of potential analytical bias and error resulting from matrix chemistry and instrument variability by evaluating the performance of seven selected trace elements in paired filtered and unfiltered surface-water and groundwater samples collected from 23 sampling sites of varying chemistries from six States, matrix spike recoveries, and standard reference materials. Filtered and unfiltered samples have been routinely analyzed on separate inductively coupled plasma-mass spectrometry instruments. Unfiltered samples are treated with hydrochloric acid (HCl) during an in-bottle digestion procedure; filtered samples are not routinely treated with HCl as part of the laboratory analytical procedure. To evaluate the influence of HCl on different sample matrices, an aliquot of the filtered samples was treated with HCl. The addition of HCl did little to differentiate the analytical results between filtered samples treated with HCl from those samples left untreated; however, there was a small, but noticeable, decrease in the number of instances where a particular trace-element concentration was greater in a filtered sample than in the associated unfiltered sample for all trace elements except selenium. Accounting for the small dilution effect (2 percent) from the addition of HCl, as required for the in-bottle digestion procedure for unfiltered samples, may be one step toward decreasing the number of instances where trace-element concentrations are greater in filtered samples than in paired unfiltered samples. The laboratory analyses of arsenic, cadmium, lead, and zinc did not appear to be influenced by instrument biases. These trace elements showed similar results on both instruments used to analyze filtered and unfiltered samples. The results for aluminum and molybdenum tended to be higher on the instrument designated to analyze unfiltered samples; the results for selenium tended to be lower. The matrices used to prepare calibration standards were different for the two instruments. The instrument designated for the analysis of unfiltered samples was calibrated using standards prepared in a nitric:hydrochloric acid (HNO3:HCl) matrix. The instrument designated for the analysis of filtered samples was calibrated using standards prepared in a matrix acidified only with HNO3. Matrix chemistry may have influenced the responses of aluminum, molybdenum, and selenium on the two instruments. The best analytical practice is to calibrate instruments using calibration standards prepared in matrices that reasonably match those of the samples being analyzed. Filtered and unfiltered samples were spiked over a range of trace-element concentrations from less than 1 to 58 times ambient concentrations. The greater the magnitude of the trace-element spike concentration relative to the ambient concentration, the greater the likelihood spike recoveries will be within data control guidelines (80–120 percent). Greater variability in spike recoveries occurred when trace elements were spiked at concentrations less than 10 times the ambient concentration. Spike recoveries that were considerably lower than 90 percent often were associated with spiked concentrations substantially lower than what was present in the ambient sample. Because the main purpose of spiking natural water samples with known quantities of a particular analyte is to assess possible matrix effects on analytical results, the results of this study stress the importance of spiking samples at concentrations that are reasonably close to what is expected but sufficiently high to exceed analytical variability. Generally, differences in spike recovery results between paired filtered and unfiltered samples were minimal when samples were analyzed on the same instrument. Analytical results for trace-element concentrations in ambient filtered and unfiltered samples greater than 10 and 40 μg/L, respectively, were within the data-quality objective for precision of ±25 percent. Ambient trace-element concentrations in filtered samples greater than the long-term method detection limits but less than 10 μg/L failed to meet the data-quality objective for precision for at least one trace element in about 54 percent of the samples. Similarly, trace-element concentrations in unfiltered samples greater than the long-term method detection limits but less than 40 μg/L failed to meet this data-quality objective for at least one trace-element analysis in about 58 percent of the samples. Although, aluminum and zinc were particularly problematic, limited re-analyses of filtered and unfiltered samples appeared to improve otherwise failed analytical precision. The evaluation of analytical bias using standard reference materials indicate a slight low bias for results for arsenic, cadmium, selenium, and zinc. Aluminum and molybdenum show signs of high bias. There was no observed bias, as determined using the standard reference materials, during the analysis of lead.

1 January 2012 in Scientific Investigations Map
Verified
Other
Closed access
KBKimberly R. Beisner
Kimberly R. Beisner
DADavid W. Anning
David W. Anning
APAngela P. Paul
Angela P. Paul
TMTim S. McKinney
Tim S. McKinney
JHJena M. Huntington
Jena M. Huntington
STSusan A. Thiros
Susan A. Thiros

1 January 2008
Verified
Report
Closed access
DMDouglas K. Maurer
Douglas K. Maurer
APAngela P. Paul
Angela P. Paul
DBDavid L. Berger
David L. Berger
CMC. Justin Mayers
C. Justin Mayers