1 January 2021 in Physics of Plasmas
An inertial electrostatic confinement (IEC) fusion device accelerates ions, such as deuterium (D) or tritium (T), to produce nuclear fusion and generate neutrons. The IEC's straightforward configuration consists of a concentric spherical transparent cathode at a negative bias surrounded by a grounded spherical anode. The effects of cathode properties on the neutron production rate (NPR) remain, to date, inadequately studied. This study aims to determine the impact of the cathode material on the NPR by investigating fusion reactions on the cathode surface. Two buckyball-shaped cathodes made of stainless steel (SS) and titanium (Ti), both of 5 cm diameter, fabricated by selective laser melting and 3D printing, are used for this investigation. A SS spherical chamber of 25 cm inner diameter is used as an anode in this experiment. A performance evaluation of surface fusion reaction in the IEC using SS and Ti grids is conducted by examining the NPR as a function of the applied voltage and grid currents at different gas pressures. So far, IEC with Ti and SS cathodes achieves NPRs of 2.32 and 1.41 × 107 n/s, respectively, at 5.6 kW (70 kV, 80 mA). The normalized NPRs (NPR/I-cathode) from IEC using SS and Ti cathodes are compared. The results demonstrate that fusion reaction occurs on the cathode surface, and fusion increases with the applied voltage. The measured NPR/I-cathode using the Ti cathode is higher than that of the SS cathode by factors of 1.36–1.64 across the 20–70 kV range. Moreover, fusion on the Ti cathode surface enhances the total NPR significantly compared to the SS cathode under the same conditions. The Ti's considerable ability to accumulate D ions and molecules compared with that of SS explains the difference of measured NPR results.
1 April 2013 in Applied Physics Express
The first ever practical-level field generation for an undulator consisting of bulk high-temperature superconductors is reported and described. A high-field short-period undulator enables bright hard X-ray to be obtained in moderate-energy synchrotrons and to provide a polarized MeV gamma-ray source for producing a polarized positron beam via pair production in future linear colliders. To generate sinusoidal magnetic fields using bulk high-temperature superconductors, a novel structure has been developed in which the superconductors line up in a staggered configuration inside a solenoid. An undulator field of 0.85 T is achieved using a 10 mm period, 4 mm gap prototype in a 2 T solenoid.
1 May 2024 in Journal of Instrumentation
The Linear International Fusion Materials Irradiation Facility Prototype Accelerator (LIPAc) is under commissioning in Rokkasho Fusion Institute in Japan and aims to accelerate 125 mA D+ at 9 MeV in Continuous Wave mode for validating the IFMIF accelerator design. To ensure a fine characterization and tuning of the machine many beam diagnostics are installed spanning from injector to the beam dump. The beam operations in 1.0 ms pulsed D+ at 5 MeV were successfully completed with a low power beam dump in 2019. Despite the challenges posed by the pandemic, the crucial transition to a new LINAC configuration was also finalized to enable operation in 1.0 ms — CW D+ at 5 MeV with the high-power beam dump. The 1st beam operation of the configuration was carried out in 2021. The experiences and challenges encountered during these beam campaigns are described in this paper.
20 May 2024 in Fusion Engineering and Design
17 September 2024 in Journal of Applied Physics
Presented herein are the outcomes of an experimental test involving a pioneering portable-active interrogation system designed for the nondestructive detection of special nuclear materials (SNMs). The system relies on the threshold energy neutron analysis concept and incorporates a portable deuterium–deuterium (DD) neutron generator producing a particle intensity of 5 × 107 n/s, coupled with three arrays of tensioned metastable fluid detectors (TMFDs) to detect secondary neutrons from the fissile material. In the presence of the fissile material, prompt fission neutrons are emitted, with an average energy of approximately 2 MeV, and around 30% of these neutrons have energies above that of the DD neutron source (2.45 MeV). The detection of a statistically significant neutron population exceeding this threshold firmly indicates the presence of SNM. TMFDs exhibit high sensitivity in efficiently detecting neutrons above the threshold while adeptly discriminating against neutrons below the threshold as well as gamma rays. This unique feature allows the interrogation system to maintain a lightweight profile without necessitating substantial shielding materials. The validation experiments involved the placement of 70 or 140 g masses of U-235 within a 1 m3 inspection volume. Measurements were carried out over 30 min intervals, repeated numerous times, both with and without U-235, at a DD neutron source intensity of 8 × 105 n/sec. Experimental count rates with natural uranium (NU) are consistently above those without NU. The probability of detection (PD) and probability of false alarm (PFA) were assessed utilizing these count rates. The DD neutron source intensity and inspection time were normalized at 5 × 107 n/sec and 90 s, respectively. The results indicated a PD of approximately 74% and 98% for detecting 70 and 140 g of U-235, respectively, with a PFA of 90%) and PFA (<5%) targets outlined in ANSI standards.
16 April 2026 in Fusion Engineering and Design