Masami Goto

Masami Goto

Auto-generated profile, based on publicly available information

Masami Goto

Department of Radiological Technology, Faculty of Health Science, Juntendo University, Tokyo, Japan

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Magnetic Resonance in Medical Sciences
Verified
Journal Article
Open access
PDF file
MGMasami Goto
Masami Goto
OAOsamu Abe
Osamu Abe
AHAkifumi Hagiwara
Akifumi Hagiwara
SFShohei Fujita
Shohei Fujita
KKKoji Kamagata
Koji Kamagata
HDHiroyuki Daida
Hiroyuki Daida
Surface-based morphometry (SBM) is extremely useful for estimating the indices of cortical morphology, such as volume, thickness, area, and gyrification, whereas voxel-based morphometry (VBM) is a typical method of gray matter (GM) volumetry that includes cortex measurement. In cases where SBM is used to estimate cortical morphology, it remains controversial as to whether VBM should be used in addition to estimate GM volume. Therefore, this review has two main goals. First, we summarize the differences between the two methods regarding preprocessing, statistical analysis, and reliability. Second, we review studies that estimate cortical morphological changes using VBM and/or SBM and discuss whether using VBM in conjunction with SBM produces additional values. We found cases in which detection of morphological change in either VBM or SBM was superior, and others that showed equivalent performance between the two methods. Therefore, we concluded that using VBM and SBM together can help researchers and clinicians obtain a better understanding of normal neurobiological processes of the brain. Moreover, the use of both methods may improve the accuracy of the detection of morphological changes when comparing the data of patients and controls.In addition, we introduce two other recent methods as future directions for estimating cortical morphological changes: a multi-modal parcellation method using structural and functional images, and a synthetic segmentation method using multi-contrast images (such as T1- and proton density-weighted images).

21 July 2021 in Investigative Radiology
Verified
Journal Article
Open access
MHMasaaki Hori
Masaaki Hori
AHAkifumi Hagiwara
Akifumi Hagiwara
MGMasami Goto
Masami Goto
AWAkihiko Wada
Akihiko Wada
SAShigeki Aoki
Shigeki Aoki
Low-field magnetic resonance imaging (MRI) systems have seen a renaissance recently due to improvements in technology (both hardware and software). Originally, the performance of low-field MRI systems was rated lower than their actual clinical usefulness, and they were viewed as low-cost but poorly performing systems. However, various applications similar to high-field MRI systems (1.5 T and 3 T) have gradually become possible, culminating with high-performance low-field MRI systems and their adaptations now being proposed that have unique advantages over high-field MRI systems in various aspects. This review article describes the physical characteristics of low-field MRI systems and presents both their advantages and disadvantages for clinical use (past to present), along with their cutting-edge clinical applications.

26 April 2013 in Neuroradiology
Verified
Journal Article
Closed access
PDF file
JIJapanese Alzheimer’s Disease Neuroimaging Initiative
Japanese Alzheimer’s Disease Neuroimaging Initiative
MGMasami Goto
Masami Goto
OAOsamu Abe
Osamu Abe
SAShigeki Aoki
Shigeki Aoki
NHNaoto Hayashi
Naoto Hayashi
KOKuni Ohtomo
Kuni Ohtomo

1 January 2016 in Magnetic Resonance in Medical Sciences
Verified
Journal Article
Open access
MGMasami Goto
Masami Goto
OAOsamu Abe
Osamu Abe
TMTosiaki Miyati
Tosiaki Miyati
HYHidenori Yamasue
Hidenori Yamasue
TGTsutomu Gomi
Tsutomu Gomi
TTTohoru Takeda
Tohoru Takeda
Resting-state functional magnetic resonance imaging (RS-fMRI) is used to investigate brain functional connectivity at rest. However, noise from human physiological motion is an unresolved problem associated with this technique. Following the unexpected previous result that group differences in head motion between control and patient groups caused group differences in the resting-state network with RS-fMRI, we reviewed the effects of human physiological noise caused by subject motion, especially motion of the head, on functional connectivity at rest detected with RS-fMRI. The aim of the present study was to review head motion artifact with RS-fMRI, individual and patient population differences in head motion, and correction methods for head motion artifact with RS-fMRI. Numerous reports have described new methods [e.g., scrubbing, regional displacement interaction (RDI)] for motion correction on RS-fMRI, many of which have been successful in reducing this negative influence. However, the influence of head motion could not be entirely excluded by any of these published techniques. Therefore, in performing RS-fMRI studies, head motion of the participants should be quantified with measurement technique (e.g., framewise displacement). Development of a more effective correction method would improve the accuracy of RS-fMRI analysis.

22 December 2010 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
MGMasami Goto
Masami Goto
OAOsamu Abe
Osamu Abe
TMTosiaki Miyati
Tosiaki Miyati
SISachiko Inano
Sachiko Inano
NHNaoto Hayashi
Naoto Hayashi
KOKuni Ohtomo
Kuni Ohtomo
Purpose: To clarify age‐related structural changes specific to hippocampal volume by hierarchizing according to age, gender, and menopausal status. Many studies report the neuroprotective effects of estrogen and age‐related brain volume changes; however, there are no studies regarding age‐related change specific to hippocampal volume in terms of age, gender, and menopausal status.Materials and Methods: T1‐weighted MR images were obtained in 412 healthy adults divided into eight groups according to age and gender, to analyze brain volume change focusing on hippocampal volume.Results: Voxel‐based morphometry (VBM) revealed significantly smaller gray matter volume in the hippocampus bilaterally in females aged in their fifties (51 of 59 females were at menopause) compared with females in their forties (3 of 46 females were at menopause). No significant difference was found, however, between female groups in their fifties versus sixties, or sixties versus seventies; or between male groups in their forties versus fifties, fifties versus sixties, or sixties versus seventies. In addition, VBM revealed significant hippocampal volume reduction bilaterally in all postmenopausal women compared with all premenopausal women.Conclusion: The results of the current study suggest that the menopause may be associated with hippocampal volume reduction. J. Magn. Reson. Imaging 2011;33:48–53.

1 May 2018 in Journal Of Neuroradiology
Verified
Journal Article
Open access
CAC. Andica
C. Andica
AHAkifumi Hagiwara
Akifumi Hagiwara
MHM. Hori
M. Hori
MNM. Nakazawa
M. Nakazawa
MGM. Goto
M. Goto
SAS. Aoki
S. Aoki
Segmented brain tissue and myelin volumes can now be automatically calculated using dedicated software (SyMRI), which is based on quantification of R1 and R2 relaxation rates and proton density. The aim of this study was to determine the validity of SyMRI brain tissue and myelin volumetry using various in-plane resolutions. We scanned 10 healthy subjects on a 1.5T MR scanner with in-plane resolutions of 0.8, 2.0 and 3.0mm. Two scans were performed for each resolution. The acquisition time was 7-min and 24-sec for 0.8mm, 3-min and 9-sec for 2.0mm and 1-min and 56-sec for 3.0mm resolutions. The volumes of white matter (WM), gray matter (GM), cerebrospinal fluid (CSF), non-WM/GM/CSF (NoN), brain parenchymal volume (BPV), intracranial volume (ICV) and myelin were compared between in-plane resolutions. Repeatability for each resolution was then analyzed. No significant differences in volumes measured were found between the different in-plane resolutions, except for NoN between 0.8mm and 2.0mm and between 2.0mm and 3.0mm. The repeatability error value for the WM, GM, CSF, NoN, BPV and myelin volumes relative to ICV was 0.97%, 1.01%, 0.65%, 0.86%, 1.06% and 0.25% in 0.8mm; 1.22%, 1.36%, 0.73%, 0.37%, 1.18% and 0.35% in 2.0mm and 1.18%, 1.02%, 0.96%, 0.45%, 1.36%, and 0.28% in 3.0mm resolutions. SyMRI brain tissue and myelin volumetry with low in-plane resolution and short acquisition times is robust and has a good repeatability so could be useful for follow-up studies.